Desa EFS26NRA Troubleshooting, Observed Problem Possible Cause Remedy, Ignitor cable dry

Page 28

TROUBLESHOOTING

WARNING: Turn off and unplug fireplace and let cool before servicing. Only a qualified service person should service and repair fireplace.

CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/pilot unit.

Note: All troubleshooting items are listed in order of operation.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

When ignitor button is pressed,

1. Ignitor electrode not con-

1.

Reconnect ignitor cable

there is no spark at ODS/pilot

 

nected to ignitor cable

 

 

 

2.

Ignitor cable pinched or wet

2.

Free ignitor cable if pinched

 

 

 

 

by any metal or tubing. Keep

 

 

 

 

ignitor cable dry

 

3.

Broken ignitor cable

3.

Replace ignitor cable

 

4.

Bad piezo ignitor

4.

Replace piezo ignitor

 

5.

Ignitor electrode positioned

5.

Replace pilot assembly

 

 

wrong

 

 

 

6.

Ignitor electrode broken

6.

Replace pilot assembly

When ignitor button is pressed, there is spark at ODS/pilot but no ignition

1.Gas supply turned off or equip- ment shutoff valve closed

2.Control knob not in PILOT position

3.Control knob not pressed in while in PILOT position

4.Air in gas lines when installed

5.Depleted gas supply (pro- pane/LP only)

6.ODS/pilot is clogged

7.Gas regulator setting is not correct

1.Turn on gas supply or open equipment shutoff valve

2.Turn control knob to PILOT position

3.Press in control knob while in PILOT position

4.Continue holding down con- trol knob. Repeat igniting op- eration until air is removed

5.Contact local propane/LP gas company

6.Clean ODS/pilot (see Cleaning and Maintenance, pages 26 and 27) or replace ODS/pilot assembly

7.Replace gas regulator

28

www.desatech.com

113110-01A

Image 28
Contents Shown with optional cabinet mantel/hearth base accessory REMOTE-READY Models VMH26PRB, VMH26NRB, EFS26NRA, EFS26PRATable of Contents Safety Information Product Identification Provide adequate clearances around air openingsOptional Remote Control Accessories Product FeaturesAssembly Local CodesProviding Adequate Ventilation Assembly AIR for Combustion VentilationUnusually Tight Construction AIR for Combustion Ventilation Determining FRESH-AIR Flow for Fireplace LocationConfined and Unconfined Space Determining if You Have a Confined or Unconfined SpaceVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installation Items InstallationCheck GAS Type BUILT-IN Fireplace Installation Fireplace ClearancesMinimum Clearance to Combustible Materials Minimum 16 inches from Side WallRough Opening for Installing Wall Optional Mantel Installation Mantel Clearances for Built-In InstallationRemoving Upper Louver Assembly and Branch Support Installing Optional Blower Accessory GA3450TAssemblingTrimTrimshippedwithmantel Installing Blower Accessory Test to make sure the blower is working properly For Built-In InstallationExtension Cord Connecting to GAS Supply External Regulator With Vent Pointing DownInstallation Items Needed Connecting Fireplace to GAS SupplyPropane/LP Checking GAS Connections Pressure Testing gas Supply Piping SystemCorrect all leaks at once Pressure Testing Fireplace Gas Connections Installing ReceiverWire harness provided in the fireplace hard- ware pack Installing 9-Volt Battery in Hand-Held Remote Control UnitRemove battery cover on back of remote con- trol unit Optional Wall MountedInstalling LOG SET and Screen Optional Wall Switch GWMS2Install the base onto the wall with the pro- vided screws For Your Safety Read Before Lighting Selector Switch OFF Position Control KnobIgnitor Button Flame Adjustment Knob Operating FireplaceManual Lighting Procedure To Turn OFF GAS To ApplianceOptional HAND-HELD Remote Operation Shutting Off FireplaceON/OFF Series Model Ghrcb Thermostat Series Model GhrctbGWMS2 Wall Mounted Switch Optional Inspecting BurnersGWMT1 Wall Mounted Thermostat Optional Operating Blower OptionalBurner Flame Pattern Cleaning MaintenanceBurner Injector Holder and Pilot AIR Inlet Hole Wiring Diagram LOG SETCabinet Air PassagewaysTroubleshooting Observed Problem Possible Cause RemedyReplace pilot assembly Ignitor cable drySafety interlock system has Low gas pressure ODS/pilot assemblyOr improperly connected Diagram, PressedBris. If found, clean burner Residues from manufacturTial operation Hours of operationGas leak. See Warning Specifications Remote-Ready ModelsReplacement Parts Service HintsTechnical Service Parts Under WarrantyIllustrated Parts Breakdown Parts List REMOTE-READY ModelsAccessories Equipment Shutoff Valve GA5010Perimeter Trim KIT GA6095 THERMOSTAT-CONTROLLED Blower KIT GA3450TReceiver and HAND-HELD Thermostat Remote Control KIT Ghrctb Receiver and HAND-HELD Remote Control KIT GhrcbCabinet Mantel and Full Hearth Base Information VideoPage Page Keep this Warranty Warranty InformationLimited Warranty VENT-FREE Compact Classic Hearth Fireplace