Desa CSDPBN Stove and Burner System Installation, Check GAS Type, Installation Items Needed

Page 20

20

STOVE AND BURNER SYSTEM INSTALLATION

Check Gas Type

Installing Gas Piping to Stove/Burner System Location

STOVE AND BURNER SYSTEM INSTALLATION

CHECK GAS TYPE

Use proper gas type for the burner system unit you are installing. If you have conflicting gas types, do not install burner system. See dealer where you purchased the stove and burner system for proper burner system according to your gas type. Conversion kits are also available for these models, see Accessories on page 38.

INSTALLING GAS PIPING TO STOVE/ BURNER SYSTEM LOCATION

WARNING: A qualified installer or service person must connect burner system to gas supply. Follow all local codes.

CAUTION: For propane/LP units, never connect burner system directly to the propane/LP supply. This burner system requires an external regulator (not supplied). Install the external regulator between the burner system and propane/LP supply.

Installation Items Needed

Before installing stove and burner system, make sure you have the items listed below.

external regulator (supplied by installer)

piping (check local codes)

sealant (resistant to propane/LP gas)

equipment shutoff valve *

test gauge connection *

sediment trap

tee joint

pipe wrench

approved flexible gas line with gas connector (if allowed by lo- cal codes) (not provided)

*A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the CSA design-certified equipment shutoff valve from your dealer.

For propane/LP connections only, the installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pressure, burner system regulator damage could occur. Install external regu- lator with the vent pointing down as shown in Figure 42. Pointing the vent down protects it from freezing rain or sleet.

CAUTION: Use only new, black iron or steel pipe. Internally-tinned copper tubing may be used in cer- tain areas. Check your local codes. Use pipe of 1/2" (12.7 mm) diameter or greater to allow proper gas volume to burner system. If pipe is too small, undue loss of volume will occur.

Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from burner system (see Figure 43).

IMPORTANT: Install main gas valve (equipment shutoff valve) in an accessible location. The main gas valve is for turning on and shutting off the gas to the appliance.

Check your building codes for any special requirements for locating equipment shutoff valve to stoves.

ExternalPropane/LP

Regulator Supply Tank

Vent Pointing

Down

Figure 42 - External Regulator with Vent Pointing Down (Propane/LP Only)

CSA Design-Certified Equipment Shutoff Valve with 1/8" NPT Tap*

Approved Flexible

Natural - From Gas

Gas Line

Meter (5" W.C. to 10.5"

 

 

W.C. Pressure)

3" Minimum

Propane/LP - From

 

 

External Regulator

 

(11" W.C. to 14" W.C.

Pipe Nipple Cap Tee Joint Pressure)

Sediment Trap/Drip Leg

Figure 43 - Gas Connection

*The CSA design-certified equipment shutoff valve may be sup- plied with the appliance or you can purchase it from your dealer.

For..com

111739-01A

Image 20
Contents For Your Safety What to do if YOU Smell GAS OWNER’S Operation and Installation ManualFor Your Safety Table of Contents Safety InformationProduct Identification ON/OFFGlossary of Terms PRE-INSTALLATION Preparation Product FeaturesLocal Codes Unpacking Stove PRE-INSTALLATION PreparationStove and Burner System Assembly Installing Optional Blower Accessory REMOVING/REPLACING Doors and GlassThermostat Blower Only Attach thermal switch and bracket Angle see . This will allow thermal switch to beOperating mode Place the green ground wire between the bottom hole onInstalling PROPANE/LP Conversion KIT Burner, Main Burner Orifice, and Pilot Orifice ConversionConversion Labeling and Placement Gas Control Valve ConversionLocation of Vent Termination Installing Rear CoverGeneral Venting General Venting Installation Planning Venting InstallationInstallation Precautions Installation for Horizontal Termination Installing Vent System in a ChaseInstalling Horizontal Vent Cap Noncombustible Exterior Venting with Two 90 Elbows Horizontal Termination ConfigurationsHorizontal Venting Installation for Vertical Termination Flat Ceiling Installation Venting with One 90 Elbow Cathedral Ceiling Installation Vertical Termination Configurations Vertical Venting Configuration Using Two 90 Elbows ElbowsHigh Altitude Installation Parts Lists for Venting Kits and ComponentsVertical Venting Number DescriptionStove and Burner System Installation Installing GAS Piping to STOVE/ Burner System LocationInstallation Items Needed Check GAS TypeChecking GAS Connections Connecting STOVE/BURNER System to GAS SupplyPressure Testing Gas Supply Piping System Installing Optional Wall Mount Switch GWMS2 Pressure Testing Burner System Gas ConnectionsInstalling Optional Wall Mounted Thermostat GWMT1 Installing Remote Receiver and 9-volt Alkaline BatteryInstalling LOGS, Lava Rock and Glowing Embers Remove glass door. See Removing/Replacing Glass Door,Lighting Instructions For Your Safety Read Before LightingOperating Stove with Burner System Manual Lighting Procedure To Turn OFF GAS To ApplianceOptional HAND-HELD Remote Operation Shutting Off Burners Only pilot stays litManual Mode Auto Thermostatic ModeSafety Features ON/OFF Series Model GhrcbOperating Optional Blower Accessory Pilot AssemblyInspecting Burners Operating Optional GWMT1 Wall Mounted ThermostatCleaning and Maintenance Glass DoorPilot and Burners LogsTroubleshooting Observed Problem Possible CauseImproper vent configuration OrificeInlet gas pressure is too low CompanyGas leak. See Warning statement AboveSpecifications Wiring DiagramReplacement Parts Parts Under WarrantyIllustrated Parts Breakdown Model SdvbncParts List KEY Part Number DescriptionStove Chassis Models Csdbn and Csdpbn Stove Chassis KEY Part Number Csdbn Csdpbn Description QTYAccessories Technical ServiceService Hints Owners Registration Form Postage Required 111739-01A Warranty Information