Example 2:

10

HORIZONTAL TERMINATION

when (HT) > (VT)

Example 2:

Simple venting configuration (only one 45º and 90° elbow)

 

See graph to determine the re- quired vertical rise VT for the re- quired horizontal run HT.

FIGURE 7

 

 

90°

FIGURE 8

 

90°

 

 

H4

45°

H1

H3 V2

 

H2

 

 

V1

90°

REQUIRED VERTICAL RISE IN INCHES (VT)

V1

= 4 ft

V2

= 1.5 ft

VT

= V1 + V2 = 4 ft + 1.5 ft = 5.5 ft

H1

= 2 ft

H2

= 1 ft

H3

= 1 ft

H4

= 1.5 ft

HR

= H1 + H2 + H3 + H4 = 2 + 1 + 1 + 1. 5 = 5.5 ft

HO

= .03(one 45º elbow + three 90º elbow -135º)

 

=.03(315-135)=5.4ft

HT

= HR + HO = 5.5 +5.4 = 10.9 ft

HT + VT = 10.9 + 5.5 = 16.4 ft

Formula 1: HT < 4.2 VT

4.2VT = 4.2 x 5.5 = 23.1 ft

10.9< 16.8

Formula 2: HT + VT < 24.75 feet

HORIZONTAL VENT RUN PLUS OFFSETS IN FEET (HT)

16.4 < 24.75

The shaded area within the lines represents acceptable values for HT and VT .

For vent configurations requiring more than one 45º and 90° elbow the following formulas apply:

Formula 1: HT < 4.2 VT

Formula 2: HT + VT < 24.75 feet

Since both formulas are met, this vent configuration is ac- ceptable.

W415-0385 / A / 10.02.03

Image 10
Contents DIRECT VENT MILLIVOLT SYSTEM 13 - 18 INSTALLATION TABLE of CONTENTSPLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE 21 OPTIONAL BLOWER INSTALLATIONISO 9001 2000 Quality Assurance Certificate CONTINENTAL GAS FIREPLACE PRESIDENTS LIFETIME LIMITED WARRANTYAny labour related to warranty repair is not covered CONDITIONS AND LIMITATIONSGENERAL INFORMATION GENERAL INSTRUCTIONSCARE OF GLASS, AND PLATED PARTS VENTING VENTING LENGTHSA B C D E F G H I J K L M N O AIR TERMINAL INSTALLATIONSINSTALLATIONS CANADIAN 12 INCHES 12 INCHES 12 INCHES 32 INCHES 32 INCHES 0 INCHESPERISCOPE TERMINATION TYPICAL VENT INSTALLATIONSSPECIAL VENT INSTALLATIONS FIGURES 3 a-cHORIZONTAL TERMINATION VENTING APPLICATION FLOW CHARTVERTICAL TERMINATION ELBOW VENT LENGTH VALUES HORIZONTAL TERMINATIONDEFINITIONS Formula 1 HT VT Formula 2 HT + VT 40 feet ExampleFormula 2 HT + VT 24.75 feet ExampleFormula 1 HT 4.2 VT Formula 1 HT 4.2 VT Formula 2 HT + VT 24.75 feetFormula 1 HT VT Formula 2 HT + VT 40 feet VERTICAL TERMINATIONFIGURE10 REQUIRED VERTICAL RISE IN FEET VT Formula 1 HT 3VT Formula 2 HT + VT 40 feet ExampleHORIZONTAL VENT RUN PLUS OFFSET IN FEET HT HORIZONTAL INSTALLATION INSTALLATION WALL AND CEILING PROTECTIONVERTICAL INSTALLATION VERTICAL AIR TERMINAL INSTALLATION USING FLEXIBLE VENT COMPONENTSHORIZONTAL AIR TERMINAL INSTALLATION Use only approved aluminum flexible liner kits markedEXTENDED HORIZONTAL AIR TERMINAL INSTALLATION USING RIGID VENT COMPONENTSFIREPLACE VENT CONNECTION Proceed once the vent installation is complete VERTICAL VENTING INSTALLATIONGAS INSTALLATION 1. Move the fireplace into position and secure using theFRAMING MOBILE HOME INSTALLATIONFIGURES Additional set screws may be installed NAILING TAB INSTALLATIONMANTLE INSTALLATION NAILINGLOGO PLACEMENT FINISHINGL42 LOUVRE INSTALLATION PORCELAIN REFLECTIVE PANELSCHARCOAL EMBERS #2#3LOG PLACEMENT VERMICULITEOPTIONAL BLOWER INSTALLATION B ACGD36 THERMOSTATIC SENSOR CONTROL OPTIONAL FAN INSTALLATIONTo safely install the fan, turn off the electricity first FOR YOUR SAFETY READ BEFORE LIGHTING OPERATION / MAINTENANCEMAINTENANCE Turn off the gas and electrical power before servicing the fireplaceVENTURI ADJUSTMENT ADJUSTMENTSPILOT BURNER ADJUSTMENT Air shutter adjustment must only be done by a qualified installerREPLACEMENT PARTS REPLACEMENTSACCESSORIES GD420 5 FTW415-0385 / A PROBLEM TROUBLE SHOOTING GUIDESYMPTOM TEST SOLUTIONTOLI