OPERATION / MAINTENANCE

OPERATING INSTRUCTIONS

When lit for the first time, the fireplace will emit a slight odour for a few hours. This is a normal temporary condi- tion caused by the curing of the logs and the "burn-in" of internal paints and lubricants used in the manufacturing process and will not occur again.

After extended periods of non-operation such as following a vacation or a warm weather season, the fireplace may emit a slight odour for a few hours. This is caused by dust particles in the heat exchanger burning off. In both cases, open a window to sufficiently ventilate the room.

Purge the gas line with the glass door removed. As- sure that a continuous gas flow is at the burner before re-installing the door.

FOR YOUR SAFETY READ BEFORE LIGHTING:

A. This fireplace is equipped with a pilot which must be lit by hand while following these instructions exactly.

B. Before operating smell all around the fireplace area for gas and next to the floor because some gas is heavier than air and will settle on the floor

C. Use only your hand to turn the gas control knob. Never use tools. If the knob will not turn by hand, do not try to repair it. Call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D. Do not use this fireplace if any part has been under water. Immediately call a qualified service technician to inspect the fireplace and replace any part of the control system and any gas control which has been under water.

WHAT TO DO IF YOU SMELL GAS

Turn off all gas to the fireplace.

 

ILOT

Open windows.

 

P

F

O

N

 

 

 

 

F

Do not try to light any appliance.

O

 

 

 

Do not touch any electric switch; do

 

 

 

not use any phone in your building.

GAS KNOB

Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire de- partment.OPERATING INSTRUCTIONSFOR YOUR SAFETY READ BEFORE LIGHTING:

OL

 

 

F

HI

O

F

 

OL

P

 

 

TOLIP

LIGHTING INSTRUCTIONS

WARNING: The gas valve has an interlock device which will not allow the pilot burner to be lit until the thermocou- ple has cooled. Allow approximately 60 seconds for the thermocouple to cool.

When lighting and re-lighting, the gas knob cannot be turned from pilot to off unless the knob is depressed slightly.

1.Stop! Read the above safety information on this label.

2.Turn off all electric power to the fireplace.

3.Turn the gas knob clockwise WHAT TO DO IF YOU SMELL GAS to off.

4.Wait five (5) minutes to clear out any gas. If you smell gas including near the floor. Stop! Follow "B" in the above safety information on this label. If you don't smell gas go the next step.

5.Turn gas knob counter-clockwise ILOT to pilot.

6.Depress slightly and hold gas knob while lighting the pilot with the push button ignitor. Keep knob depressed for one minute, then release. If pilot does not continue to burn, repeat steps 3 through 5.

7.With pilot lit, depress and turn gas knob counter-clock-

wise LIGHTING INSTRUCTIONS to on.

8.If equipped with remote on-off switch/thermostat, main burner may not come on when you turn valve to on. Remote switch must be in the on position to ignite burner.

9.Turn on all electric power to the fireplace.

TO TURN OFF GAS

1.Turn off all electric power to the fireplace if service is to be performed.

2.Push in gas control knob slightly and turn clock-

wiseTO TURN OFF GAS to off. Do not force.

MAINTENANCE

Turn off the gas and electrical power before servicing the fireplace.

CAUTION: Label all wires prior to disconnection when serv- icing controls. Wiring errors can cause improper and dan- gerous operation. Verify proper operation after servicing. This fireplace and its venting system should be inspected before use and at least annually by a qualified service person. The fireplace area must be kept clear and free of combustible materials, gasoline or other flammable va- pours and liquids. The flow of combustion and ventilation air must not be obstructed.

1.In order to properly clean the burner and pilot assembly, remove the logs to expose both assemblies.

2.Keep the control compartment, logs, burner, air shutter opening and the area surrounding the logs clean by vacu- uming or brushing, at least once a year.

3.Check to see that all burner ports are burning. Clean out any of the ports which may not be burning or are not burn- ing properly.

4.Check to see that the pilot flame is large enough to engulf the thermocouple and thermopile and reaches to- ward the burner with the third jet.

5.Replace the cleaned logs.

6.Check to see that the main burner ignites completely on all openings when the gas knob for the burner is turned on. A 5 to

10second total light-up period is satisfactory. If ignition takes longer, consult your Continental dealer / distributor.

7.Check that the gasketing on the sides, top and bottom of the door is not broken or missing. Replace if necessary.

W415-0385 / A / 10.02.03

Image 23
Contents DIRECT VENT MILLIVOLT SYSTEM 21 OPTIONAL BLOWER INSTALLATION TABLE of CONTENTSPLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE 13 - 18 INSTALLATIONCONDITIONS AND LIMITATIONS CONTINENTAL GAS FIREPLACE PRESIDENTS LIFETIME LIMITED WARRANTYAny labour related to warranty repair is not covered ISO 9001 2000 Quality Assurance CertificateCARE OF GLASS, AND PLATED PARTS GENERAL INSTRUCTIONSGENERAL INFORMATION VENTING LENGTHS VENTINGCANADIAN 12 INCHES 12 INCHES 12 INCHES 32 INCHES 32 INCHES 0 INCHES AIR TERMINAL INSTALLATIONSINSTALLATIONS A B C D E F G H I J K L M N OFIGURES 3 a-c TYPICAL VENT INSTALLATIONSSPECIAL VENT INSTALLATIONS PERISCOPE TERMINATIONVERTICAL TERMINATION VENTING APPLICATION FLOW CHARTHORIZONTAL TERMINATION Formula 1 HT VT Formula 2 HT + VT 40 feet Example HORIZONTAL TERMINATIONDEFINITIONS ELBOW VENT LENGTH VALUESFormula 1 HT 4.2 VT Formula 2 HT + VT 24.75 feet ExampleFormula 1 HT 4.2 VT Formula 2 HT + VT 24.75 feetFIGURE10 VERTICAL TERMINATIONFormula 1 HT VT Formula 2 HT + VT 40 feet HORIZONTAL VENT RUN PLUS OFFSET IN FEET HT Formula 1 HT 3VT Formula 2 HT + VT 40 feet ExampleREQUIRED VERTICAL RISE IN FEET VT VERTICAL INSTALLATION INSTALLATION WALL AND CEILING PROTECTIONHORIZONTAL INSTALLATION Use only approved aluminum flexible liner kits marked USING FLEXIBLE VENT COMPONENTSHORIZONTAL AIR TERMINAL INSTALLATION VERTICAL AIR TERMINAL INSTALLATIONFIREPLACE VENT CONNECTION USING RIGID VENT COMPONENTSEXTENDED HORIZONTAL AIR TERMINAL INSTALLATION 1. Move the fireplace into position and secure using the VERTICAL VENTING INSTALLATIONGAS INSTALLATION Proceed once the vent installation is completeFIGURES MOBILE HOME INSTALLATIONFRAMING NAILING NAILING TAB INSTALLATIONMANTLE INSTALLATION Additional set screws may be installedPORCELAIN REFLECTIVE PANELS FINISHINGL42 LOUVRE INSTALLATION LOGO PLACEMENTVERMICULITE #2#3LOG PLACEMENT CHARCOAL EMBERSB AC OPTIONAL BLOWER INSTALLATIONTo safely install the fan, turn off the electricity first OPTIONAL FAN INSTALLATIONGD36 THERMOSTATIC SENSOR CONTROL Turn off the gas and electrical power before servicing the fireplace OPERATION / MAINTENANCEMAINTENANCE FOR YOUR SAFETY READ BEFORE LIGHTINGAir shutter adjustment must only be done by a qualified installer ADJUSTMENTSPILOT BURNER ADJUSTMENT VENTURI ADJUSTMENTGD420 5 FT REPLACEMENTSACCESSORIES REPLACEMENT PARTSW415-0385 / A TEST SOLUTION TROUBLE SHOOTING GUIDESYMPTOM PROBLEMTOLI