Continental BCDV42N, BCDV42P manual Trouble Shooting Guide, Symptom, Problem, Test Solution

Page 27
TROUBLE SHOOTING GUIDE
Out of propane gas
Spark gap is incorrect
No gas at the pilot burner

27

TROUBLE SHOOTING GUIDE

BEFORE ATTEMPTING TO TROUBLESHOOT, PURGE YOUR UNIT AND INITIALLY LIGHT THE PILOT AND THE MAIN BURNER WITH THE GLASS DOOR REMOVED.

 

SYMPTOM

 

 

PROBLEM

 

TEST SOLUTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Main burner goes

Pilot flame is not large

-

turn up pilot flame.

 

out; pilot stays on.

enough or not engulfing the

- replace pilot assembly.

 

 

 

 

 

thermopile

 

 

 

 

 

 

 

 

Thermopile shorting

- clean thermopile connection to the valve. Reconnect.

 

 

 

 

 

 

 

 

- replace thermopile / valve.

 

 

 

 

 

Remote wall switch wire is

-

shorten wire to correct length or wire gauge.

 

 

 

 

 

too long; too much resist-

 

 

 

 

 

 

 

 

ance in the system.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Faulty thermostat or switch.

-

replace.

 

 

 

 

 

 

Main burner goes

Refer to "MAIN BURNER GOES OUT; PILOT STAYS ON"

out; pilot goes out.

 

 

 

 

Vent is blocked

-

check for vent blockage.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vent is re-circulating

-

check joint seals and installation.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5" flexible vent has become

-

re-attach to fireplace.

 

 

 

 

 

disconnected from fireplace.

 

 

 

 

 

 

 

 

 

 

 

Pilot goes out when

 

System is not correctly

-

purge the gas line with the glass door removed.

 

the gas knob is re-

 

purged.

 

 

 

 

leased.

 

 

 

 

 

 

 

 

 

 

 

 

Out of propane gas.

-

fill the tank.

 

The gas valve has

 

 

 

 

 

 

 

 

 

 

Pilot flame is not large

-

turn up the pilot flame.

 

an interlock device

 

 

which will not allow

 

enough

 

 

 

 

the pilot burner to

 

Pilot flame is not engulfing

-

gently twist the pilot head to improve the flame pattern around the

 

be lit until the ther-

 

the thermocouple.

thermocouple.

 

mocouple

has

 

Thermocouple shorting /

-

loosen and tighten thermocouple.

 

cooled. Allow ap-

 

faulty.

-

clean thermocouple and valve connection.

 

proximately

60

 

 

 

-

replace thermocouple.

 

seconds for the

 

 

 

 

 

 

 

-

replace valve.

 

thermocouple to

 

 

 

 

 

Faulty valve.

-

replace.

 

cool.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pilot

burning;

no

 

 

Themostat or switch is de-

-

connect a jumper wire across the wall switch terminals; if main

 

gas

to

main

 

 

fective.

burner lights, replace switch / thermostat.

 

burner; gas knob

 

 

 

 

 

 

 

 

Wall switch wiring is defec-

-

disconnect the switch wires & connect a jumper wire across termi-

 

is on 'HI'; walltive.

nals 1 & 3; if the main burner lights, check the wires for defects and

 

switch / thermostat

 

 

 

/ or replace wires.

 

is on.

 

 

 

 

 

 

 

 

 

 

Main burner orifice is plugged.

-

remove stoppage in orifice.

 

 

 

 

 

 

 

 

 

 

 

Faulty valve.

-

replace.

 

 

 

 

 

 

Pilot will not light.

 

No spark at pilot burner

-

check if pilot can be lit by a match

 

 

 

 

 

 

 

 

-

check that the wire is connected to the push button ignitor.

 

 

 

 

 

 

 

 

-

check if the push button ignitor needs tightening.

 

 

 

 

 

 

 

 

-

replace the wire if the wire insulation is broken or frayed.

 

 

 

 

 

 

 

 

-

replace the electrode if the ceramic insulator is cracked or broken.

 

 

 

 

 

 

 

 

-

replace the push button ignitor.

- fill the tank.

- spark gap should be 0.150" to 0.175" (5/32" to 11/64" approx.) from the electrode tip and the pilot burner. To ensure proper electrode location, tighten securing nut (finger tight plus 1/4 turn).

- check that the manual valve is turned on.

-check the pilot orifice for blockage.

-replace the valve.

-call the gas distributor.

W415-0385 / A / 10.02.03

Image 27
Contents DIRECT VENT MILLIVOLT SYSTEM 21 OPTIONAL BLOWER INSTALLATION TABLE of CONTENTSPLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE 13 - 18 INSTALLATIONCONDITIONS AND LIMITATIONS CONTINENTAL GAS FIREPLACE PRESIDENTS LIFETIME LIMITED WARRANTYAny labour related to warranty repair is not covered ISO 9001 2000 Quality Assurance CertificateGENERAL INSTRUCTIONS GENERAL INFORMATIONCARE OF GLASS, AND PLATED PARTS VENTING LENGTHS VENTINGCANADIAN 12 INCHES 12 INCHES 12 INCHES 32 INCHES 32 INCHES 0 INCHES AIR TERMINAL INSTALLATIONSINSTALLATIONS A B C D E F G H I J K L M N OFIGURES 3 a-c TYPICAL VENT INSTALLATIONSSPECIAL VENT INSTALLATIONS PERISCOPE TERMINATIONVENTING APPLICATION FLOW CHART HORIZONTAL TERMINATIONVERTICAL TERMINATION Formula 1 HT VT Formula 2 HT + VT 40 feet Example HORIZONTAL TERMINATIONDEFINITIONS ELBOW VENT LENGTH VALUESFormula 1 HT 4.2 VT Formula 2 HT + VT 24.75 feet ExampleFormula 1 HT 4.2 VT Formula 2 HT + VT 24.75 feetVERTICAL TERMINATION Formula 1 HT VT Formula 2 HT + VT 40 feetFIGURE10 Formula 1 HT 3VT Formula 2 HT + VT 40 feet Example REQUIRED VERTICAL RISE IN FEET VTHORIZONTAL VENT RUN PLUS OFFSET IN FEET HT INSTALLATION WALL AND CEILING PROTECTION HORIZONTAL INSTALLATIONVERTICAL INSTALLATION Use only approved aluminum flexible liner kits marked USING FLEXIBLE VENT COMPONENTSHORIZONTAL AIR TERMINAL INSTALLATION VERTICAL AIR TERMINAL INSTALLATIONUSING RIGID VENT COMPONENTS EXTENDED HORIZONTAL AIR TERMINAL INSTALLATIONFIREPLACE VENT CONNECTION 1. Move the fireplace into position and secure using the VERTICAL VENTING INSTALLATIONGAS INSTALLATION Proceed once the vent installation is completeMOBILE HOME INSTALLATION FRAMINGFIGURES NAILING NAILING TAB INSTALLATIONMANTLE INSTALLATION Additional set screws may be installedPORCELAIN REFLECTIVE PANELS FINISHINGL42 LOUVRE INSTALLATION LOGO PLACEMENTVERMICULITE #2#3LOG PLACEMENT CHARCOAL EMBERSB AC OPTIONAL BLOWER INSTALLATIONOPTIONAL FAN INSTALLATION GD36 THERMOSTATIC SENSOR CONTROLTo safely install the fan, turn off the electricity first Turn off the gas and electrical power before servicing the fireplace OPERATION / MAINTENANCEMAINTENANCE FOR YOUR SAFETY READ BEFORE LIGHTINGAir shutter adjustment must only be done by a qualified installer ADJUSTMENTSPILOT BURNER ADJUSTMENT VENTURI ADJUSTMENTGD420 5 FT REPLACEMENTSACCESSORIES REPLACEMENT PARTSW415-0385 / A TEST SOLUTION TROUBLE SHOOTING GUIDESYMPTOM PROBLEMTOLI