Continental BCDV42P, BCDV42N manual Optional Fan Installation, GD36 THERMOSTATIC SENSOR CONTROL

Page 22
OPTIONAL FAN INSTALLATION

22

OPTIONAL FAN INSTALLATION

ELECTRICAL INSTALLATION TO BE DONE BY A QUALI- FIED INSTALLER and must be connected and grounded in accordance with local codes. In the absence of local codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or the ANSI/NFPA 70 NATIONAL ELECTRICAL CODE in the United States.

To safely install the fan, turn off the electricity first.

OPTIONAL THERMOSTATIC

SENSOR

RECEPTACLE /

JUNCTION BOX

VARIABLE SPEED/

PIEZO IGNITOR

BRACKET

OPEN ENDED

SLOTS

FIGURE 48

If the fireplace was not previously equipped with a fan: route a grounded 2-wire, 60hz power cable to the junction box. At this point, it must be strain relieved and insulated.

The wire harness provided in this kit is a universal har- ness. When installed, ensure that any excess wire is con- tained, preventing it from making contact with moving or hot objects.

FIGURE 49

To ease installation of the fan, re- move the hinge screen and valve control door (lower louvres) from the base of the fireplace.

Position the vibration reducing pad into the clip and onto the threaded

stud at the other end, piercing a hole into the pad. The fan assembly must be able to be positioned entirely onto the pad.

Slide the fan assembly past the controls and into the clip. Secure using the lock washer and nut provided.

Plug the harness cord into the receptacle.

GD36 THERMOSTATIC SENSOR CONTROL

This optional kit is meant to be used only in conjunction with the GD65 Fan Kit, shown above, which may be or- dered from your Wolf Steel / Continental dealer.

With the thermostatic sensor option, the fan, when turned on, becomes thermally activated, and will automatically run approximately 15-30 minutes after the fireplace has been lit and for approximately 30-45 minutes after the fireplace has been turned off.

 

THERMODISC

 

SENSOR ASSEMBLY

 

BRACKET

FIGURE 50

RECEPTACLE /

JUNCTION BOX

 

Use of the fan increases the output of heat.

Unplug the power cord from the receptacle. Connect all wires as shown.

Attach and secure the sensor assembly bracket to the se- curing stud located next to the receptacle/junction box at the bottom left of the unit using the lock washer and wing nut. Ensure that the thermodisc touches the firebox wall.

Plug the power cord back into the receptacle.

When installed, ensure that any excess wire is contained, preventing it from making contact with moving or hot ob- jects.

FIGURE 51

W415-0385 / A / 10.02.03

Image 22
Contents DIRECT VENT MILLIVOLT SYSTEM 13 - 18 INSTALLATION TABLE of CONTENTSPLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE 21 OPTIONAL BLOWER INSTALLATIONISO 9001 2000 Quality Assurance Certificate CONTINENTAL GAS FIREPLACE PRESIDENTS LIFETIME LIMITED WARRANTYAny labour related to warranty repair is not covered CONDITIONS AND LIMITATIONSGENERAL INFORMATION GENERAL INSTRUCTIONSCARE OF GLASS, AND PLATED PARTS VENTING VENTING LENGTHSA B C D E F G H I J K L M N O AIR TERMINAL INSTALLATIONSINSTALLATIONS CANADIAN 12 INCHES 12 INCHES 12 INCHES 32 INCHES 32 INCHES 0 INCHESPERISCOPE TERMINATION TYPICAL VENT INSTALLATIONSSPECIAL VENT INSTALLATIONS FIGURES 3 a-cHORIZONTAL TERMINATION VENTING APPLICATION FLOW CHARTVERTICAL TERMINATION ELBOW VENT LENGTH VALUES HORIZONTAL TERMINATIONDEFINITIONS Formula 1 HT VT Formula 2 HT + VT 40 feet ExampleFormula 2 HT + VT 24.75 feet ExampleFormula 1 HT 4.2 VT Formula 1 HT 4.2 VT Formula 2 HT + VT 24.75 feetFormula 1 HT VT Formula 2 HT + VT 40 feet VERTICAL TERMINATIONFIGURE10 REQUIRED VERTICAL RISE IN FEET VT Formula 1 HT 3VT Formula 2 HT + VT 40 feet ExampleHORIZONTAL VENT RUN PLUS OFFSET IN FEET HT HORIZONTAL INSTALLATION INSTALLATION WALL AND CEILING PROTECTIONVERTICAL INSTALLATION VERTICAL AIR TERMINAL INSTALLATION USING FLEXIBLE VENT COMPONENTSHORIZONTAL AIR TERMINAL INSTALLATION Use only approved aluminum flexible liner kits markedEXTENDED HORIZONTAL AIR TERMINAL INSTALLATION USING RIGID VENT COMPONENTSFIREPLACE VENT CONNECTION Proceed once the vent installation is complete VERTICAL VENTING INSTALLATIONGAS INSTALLATION 1. Move the fireplace into position and secure using theFRAMING MOBILE HOME INSTALLATIONFIGURES Additional set screws may be installed NAILING TAB INSTALLATIONMANTLE INSTALLATION NAILINGLOGO PLACEMENT FINISHINGL42 LOUVRE INSTALLATION PORCELAIN REFLECTIVE PANELSCHARCOAL EMBERS #2#3LOG PLACEMENT VERMICULITEOPTIONAL BLOWER INSTALLATION B ACGD36 THERMOSTATIC SENSOR CONTROL OPTIONAL FAN INSTALLATIONTo safely install the fan, turn off the electricity first FOR YOUR SAFETY READ BEFORE LIGHTING OPERATION / MAINTENANCEMAINTENANCE Turn off the gas and electrical power before servicing the fireplaceVENTURI ADJUSTMENT ADJUSTMENTSPILOT BURNER ADJUSTMENT Air shutter adjustment must only be done by a qualified installerREPLACEMENT PARTS REPLACEMENTSACCESSORIES GD420 5 FTW415-0385 / A PROBLEM TROUBLE SHOOTING GUIDESYMPTOM TEST SOLUTIONTOLI