Continental BCDV42P, BCDV42N #2#3, Charcoal Embers, Vermiculite, Charcoal Lumps, Log Placement

Page 20
LOG PLACEMENT

20

LOG PLACEMENT

PHAZERTM logs and glowing embers, exclusive to Conti-

 

nental Fireplaces, provide a unique and realistic glowing

 

effect that is different in every installation. Take the time to

 

carefully position the glowing embers for a maximum glow-

 

ing effect. Log colours may vary. During the initial use of the

#5

fireplace, the colours will become more uniform as colour

pigments burn in during the heat activated curing process.

#4

FIGURES41a-d

4. Cradle the notch on the bottom of the left crossover log (#4) around the left outermost grate post and the top into the pocket provided on the back log. Position the notch

#1located on the end of the center log (#5) against the middle grate post with the other end of the log resting in the pocket of the left crossover log.

1.Place the back log (#1) onto the log support tray and in front of the tabs. The tabs maintain an air space between the log and firebox back to facilitate combustion air flow. Ensure that the back of the log rests against the brackets on the back wall of the firebox.

#2#3

2.Move the two small logs (#2 & #3) into position, lining up the studs located on the burner with the holes on the bottom of the logs.

GLOWING EMBERS

3.Tear the glowing embers into pieces and place along the front row of ports covering all of the burner area in front of the small logs (#2 & #3). Care should be taken to shred the embers into thin, small irregular pieces as only the exposed edges of the fibre hairs will glow. The ember material will only glow when exposed to direct flame; however, care should be taken to not block the burner ports. Blocked burner ports can cause an incorrect flame pattern, carbon deposits and delayed ignition. PHAZERTM logs glow when exposed to di- rect flame.

#6

5.Place the bottom of the right crossover log (#6) against the right outermost grate post. The post should rest in the pocket formed by the knot and the top into the pocket pro- vided on the center log (#5).

CHARCOAL EMBERS

Randomly place the charcoal embers along the front and sides of the log support tray in a realistic manner. Fine dust found in the bottom of the bag should not be used.

VERMICULITE

Sprinkle vermiculite around the charcoal embers.

Note: Both charcoal embers and vermiculite are not to be placed on the burner.

CHARCOAL LUMPS

Place the lumps between the logs in a realistic manner taking care not to block any of the burner ports.

W415-0385 / A / 10.02.03

Image 20
Contents DIRECT VENT MILLIVOLT SYSTEM TABLE of CONTENTS PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE13 - 18 INSTALLATION 21 OPTIONAL BLOWER INSTALLATIONCONTINENTAL GAS FIREPLACE PRESIDENTS LIFETIME LIMITED WARRANTY Any labour related to warranty repair is not coveredISO 9001 2000 Quality Assurance Certificate CONDITIONS AND LIMITATIONSCARE OF GLASS, AND PLATED PARTS GENERAL INSTRUCTIONSGENERAL INFORMATION VENTING VENTING LENGTHSAIR TERMINAL INSTALLATIONS INSTALLATIONSA B C D E F G H I J K L M N O CANADIAN 12 INCHES 12 INCHES 12 INCHES 32 INCHES 32 INCHES 0 INCHESTYPICAL VENT INSTALLATIONS SPECIAL VENT INSTALLATIONSPERISCOPE TERMINATION FIGURES 3 a-cVERTICAL TERMINATION VENTING APPLICATION FLOW CHARTHORIZONTAL TERMINATION HORIZONTAL TERMINATION DEFINITIONSELBOW VENT LENGTH VALUES Formula 1 HT VT Formula 2 HT + VT 40 feet ExampleExample Formula 1 HT 4.2 VTFormula 2 HT + VT 24.75 feet Formula 1 HT 4.2 VT Formula 2 HT + VT 24.75 feetFIGURE10 VERTICAL TERMINATIONFormula 1 HT VT Formula 2 HT + VT 40 feet HORIZONTAL VENT RUN PLUS OFFSET IN FEET HT Formula 1 HT 3VT Formula 2 HT + VT 40 feet ExampleREQUIRED VERTICAL RISE IN FEET VT VERTICAL INSTALLATION INSTALLATION WALL AND CEILING PROTECTIONHORIZONTAL INSTALLATION USING FLEXIBLE VENT COMPONENTS HORIZONTAL AIR TERMINAL INSTALLATIONVERTICAL AIR TERMINAL INSTALLATION Use only approved aluminum flexible liner kits markedFIREPLACE VENT CONNECTION USING RIGID VENT COMPONENTSEXTENDED HORIZONTAL AIR TERMINAL INSTALLATION VERTICAL VENTING INSTALLATION GAS INSTALLATIONProceed once the vent installation is complete 1. Move the fireplace into position and secure using theFIGURES MOBILE HOME INSTALLATIONFRAMING NAILING TAB INSTALLATION MANTLE INSTALLATIONAdditional set screws may be installed NAILINGFINISHING L42 LOUVRE INSTALLATIONLOGO PLACEMENT PORCELAIN REFLECTIVE PANELS#2#3 LOG PLACEMENTCHARCOAL EMBERS VERMICULITEOPTIONAL BLOWER INSTALLATION B ACTo safely install the fan, turn off the electricity first OPTIONAL FAN INSTALLATIONGD36 THERMOSTATIC SENSOR CONTROL OPERATION / MAINTENANCE MAINTENANCEFOR YOUR SAFETY READ BEFORE LIGHTING Turn off the gas and electrical power before servicing the fireplaceADJUSTMENTS PILOT BURNER ADJUSTMENTVENTURI ADJUSTMENT Air shutter adjustment must only be done by a qualified installerREPLACEMENTS ACCESSORIESREPLACEMENT PARTS GD420 5 FTW415-0385 / A TROUBLE SHOOTING GUIDE SYMPTOMPROBLEM TEST SOLUTIONTOLI