Enviro owner manual Meridian on Floor

Page 13

Installation

CLEARANCES TO COMBUSTIBLES - FREESTANDING:

These dimensions are minimum clearances but it is recommended that you ensure sufficient room for serving, routine cleaning and maintenance.

 

Back wall

 

 

3" (76mm)

Adjacent

 

wall

 

 

2"

wall

 

(51mm)

 

 

Side

6"

 

 

(152mm)

 

Minimum

 

 

6" (150mm)

 

 

Figure 10: Meridian on Floor

 

Figure 11: Minimum Clearances to Combustibles for

Protection.

 

Freestanding Meridian.

This pellet stove requires floor protection. The floor protection must be non-combustible, extending beneath the stove the full width and depth of the unit including 6“ (150 mm) in front for ember protection.

ALCOVE CLEARANCES - FREESTANDING:

Minimum Width

36" (914mm)

Minimum Height

48" (1219mm)

Maximum Depth

30" (762mm)

Figure 12: Alcove Clearances Freestanding Meridian.

13

Image 13
Contents Meridian Table of Contents I. Pellet Standards IntroductionUSE of Cordwood is Prohibited by LAW Keep ASH PAN Free of RAW Fuel Circuit Board Control Panel Decal Operating InstructionsInitial START-UP See above Thermostat / Switch ModeTools Required to Clean Unit Routine Cleaning and MaintenanceDoor Glass Cleaning 2-3 days Burn POT and Liner 2-3 daysDo not Place Unburned or RAW Pellet Fuel in ASH PAN Post Season CLEAN-UP Installation of firebox backingCleaning Plated Surfaces Firebox PanelRemoving Freestanding Stove From the Pallet Installation32 1/2 826mm 24 7/8 24 3/4 632mm 629mm Meridian on Floor Optional Hopper Cover Screw Placement Freestanding Insert ExhaustFresh AIR Intake Crawlspace, narrow Walkway Closely Installation Pipe Must Extend Least Cm away Elbow with a rodent screen may be used Inside Vertical Installation Outside Vertical Installation Hearth Mount Side View Exterior Exhaust Blower Exhaust Blower Installation Horizontal Termination To Supply Power to the Exhaust BlowerExhaust Blower Installation Vertical Termination Before starting installation Noncombustible Hearth Pad Removal Wiring harness from the bottom of the circuit board controlSurround in then down to Tools Required Removal of Louver BAR SET Clean all plated surfaces before starting the stove. SeePin Placement on Circuit Board Hole for Pressure test with Special NotesStove will not operate when hot TroubleshootingDo not What to do ifLight # 2 on Heat output bar flashing Exhaust motor will not function normallyControl settings Heat Level has no effect on the fire 200 F 93 C high limit temperature sensor has trippedConvection blower will not function normally Ignitor- the pellets will not light5V DC Wiring DiagramReference Number Description Part Number Parts ListLouver Bar Set Gold Meridian Freestanding Steel Parts Parts Diagram Insert Steel Parts Diagram Components To the Distributor WarrantyFor the do-it-yourself Individual Name of Owner Address Installation Data Sheet