Installation
10. The | pipe | must |
|
| |||
extend | at | least |
|
| |||
12” | (30 | cm) away |
|
| |||
from | the | building. |
|
| |||
If necessary, bring |
| Exhaust Tube | |||||
another | length | of |
| ||||
|
| ||||||
pipe | (PL | type) | to |
| 3" (75mm) or 4" (100mm) | ||
the | outside | of | the |
| "PL" or "L" vent | ||
| Wall Thimble | ||||||
home to connect to |
| ||||||
|
| ||||||
the first section. Do |
|
| |||||
not forget | to place |
|
| ||||
high | temperature |
|
| ||||
silicone | around | the |
| 45° Elbow with screen | |||
pipe | that |
| passes |
| or Termination Cap | ||
|
|
| |||||
through |
|
|
| the |
|
| |
thimble. |
|
|
|
|
|
| |
11. Install | a |
| vertical | Fresh Air Intake | High Temperature RTV | ||
pipe, or |
| if | all | ||||
|
| Silicone Required | |||||
requirements | for |
| |||||
|
| ||||||
direct |
|
| venting | Figure 23: Straight through wall Installation. | |||
are | met, |
| install |
vent termination. The stainless steel cap termination manufactured by the vent manufacturer is recommended. However, when the vent terminates several feet above ground level and there are no trees, plants, etc. within several feet, a 45° elbow can be used as termination. The elbow must be turned down to prevent rain from entering.
NOTE:
•Some horizontal through wall installations may require a “T” and 3 to 5 feet (91 to 152 cm) of vertical pipe outside the building to help naturally draft in the unit.
•This may be required if a proper burn cannot be maintained, after the stove has been tested and the airflow set.
•This is due to the back pressure in the exhaust caused by airflow around the structure.
•All sections of pipe must have three (3) screws evenly spaced and all horizontal and vertical vent sections located within the house must have a bead of high temperature silicone installed on the male end of the pipe before installation to create a gas tight seal.
•The termination must be 12 inches (30 cm) from the outside wall and 12 inches (30 cm) above the ground.
•A 45° elbow with a rodent screen may be used in place of the termination cap (or stainless steel termination hood).
Wall framing |
Horizontal frame |
for thimble |
Vent pipe |
Termination |
cap |
Wall thimble |
ENVIRO Meridian |
Figure 24: Straight through Wall Installation - Side View.
19