Enviro Meridian owner manual Exterior Exhaust Blower

Page 24

Installation

INSTALLATION WITH EXTERIOR MOUNTED EXHAUST BLOWER - FREESTANDING:

The MERIDIAN can be equipped with an externally mounted exhaust blower (PART #20-070). This optional kit will include all components necessary to install the exhaust blower on any external vertical wall surface.

Choose a location for your stove that meets the requirements stated in this manual and allows installation with the least amount of interference to house framing, plumbing, wiring, etc.

Included in the exterior mounted exhaust blower kit are: 1 - Exhaust blower housing box.

1 - Blower cover plate.

1 - Hardware bag

1.Open the left side of the unit and the back grill and disconnect the Exhaust Blower wires from the harness. Remove the exhaust blower by undoing the six (6) 1⁄4 hex head sheet metal screws that fasten the blower to the housing.

2.Remove the back grill from the exterior exhaust vent housing and remove the round cover plate installed on the blower housing.

3.Install the round cover plate over the gasketed opening in the stove where the exhaust motor was removed from.

4.Install the exhaust blower motor in the Exterior Vent Housing Box onto the exhaust blower housing.

5.Follow the procedures for INSTALLATION - HORIZONTAL EXHAUST THROUGH WALL INSTALLATION - FREESTANDING. Place the unit in

the desired location. Cut the hole in the wall at the desired location. Install a wall thimble.

6.Drill holes in the wall thimble in the corresponding locations for wire and fresh air if needed. Install wire clamps and feed wire through the hole in the thimble into the house. Tighten clamp on wire and attach green ground wire (at the symbol) with the screw and star washer provided.

7.Attach a short or an adjustable section of 3” of double wall pellet vent through the wall thimble to the stove. Seal all joints with silicone. Maintain clearances to combustibles.

8.Apply silicone to the pipe in the Exhaust Box, slide the pipe into the exhaust vent. Mount the Exhaust Box to the house. Reinstall the back grill on the Exterior Vent Housing Box. Apply normal venting practices when installing the vertical vent pipe.

9.Connect the wires in the stove. Re-install the Left side and Back Grill on the stove.

10.Set the Slider Damper as described in the INSTALLATION -

SLIDER/DAMPER SETTING“ section.

Left side with cab side removed

Exhaust motor must be replaced with cover

Exhaust motor

Complete assembly - Exterior

blower & housing

Figure 31: Exterior Exhaust Blower.

24

Image 24
Contents Meridian Table of Contents Introduction I. Pellet StandardsUSE of Cordwood is Prohibited by LAW Keep ASH PAN Free of RAW Fuel Operating Instructions Circuit Board Control Panel DecalThermostat / Switch Mode Initial START-UP See aboveRoutine Cleaning and Maintenance Tools Required to Clean UnitDoor Glass Cleaning 2-3 days Burn POT and Liner 2-3 daysDo not Place Unburned or RAW Pellet Fuel in ASH PAN Installation of firebox backing Post Season CLEAN-UPCleaning Plated Surfaces Firebox PanelInstallation Removing Freestanding Stove From the Pallet32 1/2 826mm 24 7/8 24 3/4 632mm 629mm Meridian on Floor Optional Hopper Cover Screw Placement Exhaust Freestanding InsertFresh AIR Intake Crawlspace, narrow Walkway Closely Installation Pipe Must Extend Least Cm away Elbow with a rodent screen may be used Inside Vertical Installation Outside Vertical Installation Hearth Mount Side View Exterior Exhaust Blower To Supply Power to the Exhaust Blower Exhaust Blower Installation Horizontal TerminationExhaust Blower Installation Vertical Termination Before starting installation Noncombustible Hearth Pad Wiring harness from the bottom of the circuit board control RemovalSurround in then down to Tools Required Clean all plated surfaces before starting the stove. See Removal of Louver BAR SETPin Placement on Circuit Board Special Notes Hole for Pressure test withTroubleshooting Stove will not operate when hotDo not What to do ifExhaust motor will not function normally Light # 2 on Heat output bar flashing200 F 93 C high limit temperature sensor has tripped Control settings Heat Level has no effect on the fireConvection blower will not function normally Ignitor- the pellets will not lightWiring Diagram 5V DCParts List Reference Number Description Part NumberLouver Bar Set Gold Meridian Freestanding Steel Parts Parts Diagram Insert Steel Parts Diagram Components Warranty To the DistributorFor the do-it-yourself Individual Installation Data Sheet Name of Owner Address