Troubleshooting

6. The 200 °F ( 93 °C) high limit temperature sensor has tripped.

üReset sensor and determine cause – was it convection blower failure or 160 °F ( 71 °C) temperature sensor failure? Bypass the 160 °F ( 71 °C) sensor, does the convection blower come on high? If no, replace the blower. If yes, replace sensor (located on the left side of the firewall).

üCheck the fuses on the circuit board (see “TROUBLESHOOTING - FUSES”).

7.The convection blower will not function normally.

üClean all grill openings at the back and below unit .

üPress the fan button; does the fan come on? Press again to verify that the blower turns on; if, not contact your local dealer for service.

8.Ignitor- the pellets will not light.

(Everything else in the stove operates but the ignitor will not light the pellets.)

üMake sure the burn pot liner is up tight and square to the ignitor tube by pushing the burn pot back against the ignitor tube.

üCheck to see if the exhaust blower is operating. If not, contact your local dealer for service. üCheck the fuses on the circuit board (see “TROUBLESHOOTING - FUSES”).

NOTE: The ignitor should be bright orange in color. If not replace the ignitor.

9. Control settings (Heat Level) has no effect on the fire.

üNote: If the system light is flashing the control board has complete control of the unit. When the units system light becomes solid then control of the unit is given back to the operator.

üIf there is no control of the heat level button make sure the thermostat is calling for heat. üCall your local dealer for service.

10. The stove keeps going out.

a)If the stove goes out and leaves fresh unburned pellets or cigarette-like ashes in the burn pot liner, the fire is going out before the stove shuts off.

üCheck to see that the slider / damper is in the correct position.

üTurn the heat level up slightly (poor quality pellets will require slightly higher settings). üSet the auger trim till the #1 and #5 lights are illuminated.

b)If the stove goes out and there are partially burned pellets left in the burn pot liner, the stove has shut down due to a lack of air, exhaust temperature, or power failure.

üAdjust the slider / damper.

üCheck to see if the stove needs a more complete cleaning.

üTurn the heat level up slightly (poor quality pellets will require slightly higher settings). üDid the power go out?

üContact your local dealer for service.

FUSES:

F1 is the fuse to the inside of the circuit board controls. If F1 has blown there may have been an input power overload or a short in the convection fan.

F2 fuse closest fuse to the outside edge of the circuit board controls. If fuse F2 has blown then there was a electrical overload problem with one of the following parts: ignitor, auger motor, high limit switch, or exhaust blower.

36

Image 36
Contents Meridian Table of Contents Introduction I. Pellet StandardsUSE of Cordwood is Prohibited by LAW Keep ASH PAN Free of RAW Fuel Operating Instructions Circuit Board Control Panel DecalThermostat / Switch Mode Initial START-UP See aboveRoutine Cleaning and Maintenance Tools Required to Clean UnitDoor Glass Cleaning 2-3 days Burn POT and Liner 2-3 daysDo not Place Unburned or RAW Pellet Fuel in ASH PAN Installation of firebox backing Post Season CLEAN-UPCleaning Plated Surfaces Firebox PanelInstallation Removing Freestanding Stove From the Pallet32 1/2 826mm 24 7/8 24 3/4 632mm 629mm Meridian on Floor Optional Hopper Cover Screw Placement Exhaust Freestanding InsertFresh AIR Intake Crawlspace, narrow Walkway Closely Installation Pipe Must Extend Least Cm away Elbow with a rodent screen may be used Inside Vertical Installation Outside Vertical Installation Hearth Mount Side View Exterior Exhaust Blower To Supply Power to the Exhaust Blower Exhaust Blower Installation Horizontal TerminationExhaust Blower Installation Vertical Termination Before starting installation Noncombustible Hearth Pad Wiring harness from the bottom of the circuit board control RemovalSurround in then down to Tools Required Clean all plated surfaces before starting the stove. See Removal of Louver BAR SETPin Placement on Circuit Board Special Notes Hole for Pressure test withTroubleshooting Stove will not operate when hotDo not What to do ifExhaust motor will not function normally Light # 2 on Heat output bar flashing200 F 93 C high limit temperature sensor has tripped Control settings Heat Level has no effect on the fireConvection blower will not function normally Ignitor- the pellets will not lightWiring Diagram 5V DCParts List Reference Number Description Part NumberLouver Bar Set Gold Meridian Freestanding Steel Parts Parts Diagram Insert Steel Parts Diagram Components Warranty To the DistributorFor the do-it-yourself Individual Installation Data Sheet Name of Owner Address