Enviro Meridian owner manual Special Notes, Hole for Pressure test with

Page 33

Installation

HEAT LEVEL and when turned down to LOW HEAT LEVEL, a 0.07” to 0.11” w.c. (0.018 to 0.028

KPa). Some fuels may require higher or lower settings.

The pressure readings are taken through a hole in the front of the firebox under the door, using a Magnehelic Gauge.

Exhaust Blower

Exhaust

Channel

Slider

Damper

Figure 48: Hole for Pressure test with

Note: Some parts

have been removed in order

Magnehelic Gauge.

to see components more clearly.

Figure 49: Slider / Damper

The slider damper is located behind the left cab side. The door must be open for the cab side to be removed on all models. On freestanding model loosen the two T-20 torx screws, one above and one below hinge, swing open left panel to access. On insert model remove the two (2) T-20 torx screws on the front, one above and one below hinge, and the one T-20 at the top of the cab side under the top front.

The combustion exhaust blower is a variable speed blower controlled by the heat output button. This blower will decrease the vacuum pressure inside the stove and as the heat output button is turned down. The vacuum pressure inside the firebox will increase as the combustion exhaust blower increases in speed (higher heat output setting).

If the fire should happen to go out and the heat output indicator has been set on the lowest setting, the Slider Damper should be pushed in slightly, decreasing the air in the firebox.

If, after long periods of burning, the fire builds up and overflows the burn pot or there is a build up of clinkers, this would be a sign that the pellet quality is poor, this requires more primary air, the slider damper must be pulled out to compensate. Pulling the slider damper out gives the fire more air.

The easiest way to make sure that an efficient flame is achieved is to understand the characteristics of the fire.

A tall, lazy flame with dark orange tips requires more air – Open slider (pull out) slightly.

A short, brisk flame, like a blowtorch, has too much air – Close slider (push in) slightly.

If the flame is in the middle of these two characteristics with a bright yellow/orange, active flame with no black tips then the air is set for proper operation.

SPECIAL NOTES:

Pellet quality is a major factor in how the pellet stove will operate. If the pellets have a high moisture content or ash content the fire will be less efficient and has a higher possibility of the fire building up and creating clinkers (hard ash build-up). If this happens, pull the Slider Damper out slightly to increase the air flow to the fire.

33

Image 33
Contents Meridian Table of Contents I. Pellet Standards IntroductionUSE of Cordwood is Prohibited by LAW Keep ASH PAN Free of RAW Fuel Circuit Board Control Panel Decal Operating InstructionsInitial START-UP See above Thermostat / Switch ModeTools Required to Clean Unit Routine Cleaning and MaintenanceDoor Glass Cleaning 2-3 days Burn POT and Liner 2-3 daysDo not Place Unburned or RAW Pellet Fuel in ASH PAN Post Season CLEAN-UP Installation of firebox backingCleaning Plated Surfaces Firebox PanelRemoving Freestanding Stove From the Pallet Installation32 1/2 826mm 24 7/8 24 3/4 632mm 629mm Meridian on Floor Optional Hopper Cover Screw Placement Exhaust Freestanding InsertFresh AIR Intake Crawlspace, narrow Walkway Closely Installation Pipe Must Extend Least Cm away Elbow with a rodent screen may be used Inside Vertical Installation Outside Vertical Installation Hearth Mount Side View Exterior Exhaust Blower Exhaust Blower Installation Horizontal Termination To Supply Power to the Exhaust BlowerExhaust Blower Installation Vertical Termination Before starting installation Noncombustible Hearth Pad Removal Wiring harness from the bottom of the circuit board controlSurround in then down to Tools Required Removal of Louver BAR SET Clean all plated surfaces before starting the stove. SeePin Placement on Circuit Board Hole for Pressure test with Special NotesStove will not operate when hot TroubleshootingDo not What to do ifLight # 2 on Heat output bar flashing Exhaust motor will not function normallyControl settings Heat Level has no effect on the fire 200 F 93 C high limit temperature sensor has trippedConvection blower will not function normally Ignitor- the pellets will not light5V DC Wiring DiagramReference Number Description Part Number Parts ListLouver Bar Set Gold Meridian Freestanding Steel Parts Parts Diagram Insert Steel Parts Diagram Components Warranty To the DistributorFor the do-it-yourself Individual Name of Owner Address Installation Data Sheet