UltraPort Serial Adaptors User Guide
SCO OpenServer 5 Page 143
SCO OpenServer 5 error messages
Error message Reason Action required
ERROR: unit @0xnnnnnnnn has
bad resource(s) Incorrectly installed or faulty
card.
Incorrect BIOS settings.
1. Ensure that you have followed the
installation procedure correctly.
See page 46.
2. Check BIOS settings.
3. If the problem persists try another card.
See page 46 and page 9 5.
ERROR: unit @0xnnnnnnnn not
mapped Insufficient memory available
to kernel. Reconfigure system/kernel memory
parameters.
ERROR: unit @0xnnnnnnnn not
initialised Incorrectly installed or faulty
card. 1. Ensure that you have followed the
installation procedure correctly.
See page 46.
2. If the problem persists try another card.
See page 46 and page 9 5.
WARNING: unit @0xnnnnnnnn not
configured System error. 1. Uninstall the driver and remove all
Speed cards from the system.
See page 61
2. Re-install the driver and cards taking
care to follow the correct procedure.
See page 46 and page 9 5.
WARNING: No Speed ports
configured No cards installed.
Installed cards suffer from
one or more of above
symptoms.
1. Install cards. See page 95.
2. Resolve any above listed faults.