Enviro Meridian owner manual Do not Place Unburned or RAW Pellet Fuel in ASH PAN

Page 9

Routine Cleaning and Maintenance

ASH PAN AND DOOR GASKETS (weekly)

After extended use the gasketing may come loose. To repair this, glue the gasketing on using high- temperature fiberglass gasket glue available from your local ENVIRO dealer. This is important to maintain an airtight assembly.

ASH PAN (weekly)

The ash pan is located under the burner. Dump the ashes into a metal container stored away from combustibles. Monitor the ash level every week. Remember that different pellet fuels will have different ash contents. Ash content is a good indication of fuel efficiency and quality. Refer to “INTRODUCTION -

SAFETY WARNINGS AND RECOMMENDATIONS” for disposal of ashes.

Freestanding: To remove the ash pan, simply turn the knob and pull out towards the front.

Insert: To remove the ash pan open the door, remove the burn pot liner and the burn pot, then pull the ash pan out.

DO NOT PLACE UNBURNED OR RAW PELLET FUEL IN ASH PAN.

HEAT EXCHANGER TUBES (weekly)

Open the door and the rod is located under the unit top, in the center of the stove just behind the door (see Figure 4). This handle is to be pushed in and out a few times (ONLY WHEN THE UNIT IS COLD) in order to clean away any fly ash that may have collected on the heat exchanger tubes. As different types of pellets produce different amounts of ash, cleaning of the tubes should be done on a regular basis to enable the unit to run efficiently.

FRESH AIR INTAKE (season)

Tube cleaner rod

Figure 4: Heat Exchanger Tube Cleaner.

Inspect periodically to be sure that it is not clogged with any foreign materials.

EXHAUST VENT (season)

This vent should be cleaned every year or after two (2) tons of pellets. We recommend contacting your dealer for professional cleaning. To clean the vent pipe, tap lightly on the pipe to dislodge any loose ash. Open the bottom of the “T” to dump the ash, then vacuum as much of the ash out of the vent pipe as possible.

BLOWER MECHANISMS (season)

Unplug the stove then open the right and left side panels to access the two blowers. Vacuum all dust from motors. DO NOT lubricate the motors. Check gaskets and replace if needed.

ALL HINGES (season)

Check all the hinges on the unit to ensure proper movement.

9

Image 9
Contents Meridian Table of Contents I. Pellet Standards IntroductionUSE of Cordwood is Prohibited by LAW Keep ASH PAN Free of RAW Fuel Circuit Board Control Panel Decal Operating InstructionsInitial START-UP See above Thermostat / Switch ModeTools Required to Clean Unit Routine Cleaning and MaintenanceDoor Glass Cleaning 2-3 days Burn POT and Liner 2-3 daysDo not Place Unburned or RAW Pellet Fuel in ASH PAN Post Season CLEAN-UP Installation of firebox backingCleaning Plated Surfaces Firebox PanelRemoving Freestanding Stove From the Pallet Installation32 1/2 826mm 24 7/8 24 3/4 632mm 629mm Meridian on Floor Optional Hopper Cover Screw Placement Exhaust Freestanding InsertFresh AIR Intake Crawlspace, narrow Walkway Closely Installation Pipe Must Extend Least Cm away Elbow with a rodent screen may be used Inside Vertical Installation Outside Vertical Installation Hearth Mount Side View Exterior Exhaust Blower Exhaust Blower Installation Horizontal Termination To Supply Power to the Exhaust BlowerExhaust Blower Installation Vertical Termination Before starting installation Noncombustible Hearth Pad Removal Wiring harness from the bottom of the circuit board controlSurround in then down to Tools Required Removal of Louver BAR SET Clean all plated surfaces before starting the stove. SeePin Placement on Circuit Board Hole for Pressure test with Special NotesStove will not operate when hot TroubleshootingDo not What to do ifLight # 2 on Heat output bar flashing Exhaust motor will not function normallyControl settings Heat Level has no effect on the fire 200 F 93 C high limit temperature sensor has trippedConvection blower will not function normally Ignitor- the pellets will not light5V DC Wiring DiagramReference Number Description Part Number Parts ListLouver Bar Set Gold Meridian Freestanding Steel Parts Parts Diagram Insert Steel Parts Diagram Components Warranty To the DistributorFor the do-it-yourself Individual Name of Owner Address Installation Data Sheet