Enviro DV50DX owner manual Initial Installation, Qualified Installers Only

Page 16
Manual background

Initial Installation

QUALIFIED INSTALLERS ONLY

VENT TERMINATION RESTRICTIONS:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N

 

 

 

 

 

 

 

 

 

O

D

E

 

 

 

 

 

H

 

 

B

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

L

B

Fixed

 

 

B

 

 

 

G

F

Closed

Openable

Fixed

 

 

G

 

 

Openable

Closed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M

 

 

B

 

A

 

J

 

 

K

 

 

 

 

 

 

 

 

 

 

 

 

I

A

 

Termination Cap

 

Air Supply Inlet

 

 

 

 

G

Gas Meter

Restriction Zone

 

 

 

 

 

 

 

 

 

(Termination not allowed)

 

Figure 17. Vent Termination Restrictions, refer to Table 2.

Table 2: Vent termination clearances, refer to Figure 17.

Letter

Canadian Installation 1

US Installation2

Description

A

12 in (30 cm)

Clearance above grade, verandah, porch, deck, or balcony.

 

 

 

 

B

12 in (30 cm)

9 in (23 cm)

Clearance from window or door that may be opened.

 

 

 

 

C

12 in (30 cm)*

Clearance from permanently closed window (to prevent

 

 

 

condensation).

 

 

 

D

24 in (60 cm)*

Vertical clearance to ventilated soffit located above the

 

 

 

terminal, within a horizontal distance of 2 ft (60 cm) from

 

 

 

center line of terminal.

 

 

 

E

18 in (45 cm)*

Clearance to unventilated soffit.

 

 

 

F

12 in (30 cm)*

Clearance to outside corner.

 

 

 

G

12 in (30 cm)*

Clearance to inside corner.

 

 

 

 

H

3 ft (91 cm) within a height of

3 ft (91 cm) within a height of

Clearance to each side of center line extended above

 

15 ft (4.5 m) above the meter/

15 ft (4.5 m) above the meter/

meter/regulator assembly.

 

regulator assembly

regulator assembly*

 

 

 

 

 

I

3 ft (91 cm)

3 ft (91 cm)*

Radial clearance around service regulator vent outlet.

 

 

 

 

J

12 in (30 cm)

9 in (23 cm)

Clearance to non-mechanical air supply inlet to building, or

 

 

 

the combustion air inlet to any other appliance.

 

 

 

 

K

6 ft (1.83 m)

3 ft (91 cm) above if within 10

Clearance to mechanical air supply inlet.

 

 

ft (3 m) horizontally

 

 

 

 

 

L

7 ft (2.13 m)t

7 ft (2.13 m)*t

Clearance above paved sidewalk or paved driveway located

 

 

 

on public property.

 

 

 

 

M

12 in / 30 cm+

12 in / 30 cm*+

Clearance under verandah, porch, deck, or balcony.

N

12 in (30 cm)*

Clearance horizontally to any surface (such as an exterior

 

 

 

wall) for vertical terminations.

 

 

 

O

12 in (30 cm)

Clearance above roof line for vertical terminations.

 

 

 

 

1In accordance with the current CSA B149, Natural Gas and Propane Installation Code.

2 In accordance with the current ANSI Z223.1 NFPA 54, National Fuel Gas Code.

* These numbers are only estimates. Clearance in accordance with installation codes and the requirements of the gas supplier.

t A vent shall not terminate directly above a side walk or paved driveway that is located between two single family dwellings and it serves both dwellings. + Permitted only if verandah, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor.

NOTE: Venting terminals shall not be recessed into walls or siding.

16

Image 16
Contents WHAT TO DO IF YOU SMELL GAS DV50DXOpen windows/extinguish any open flame Do not try to light any applianceFOR YOUR SAFETY Safety PrecautionsGENERAL Table of Contents VENTED GAS FIREPLACE HEATER DV50DX NG/LPG Codes And ApprovalsThis ENVIRO DV50DX Fireplace Specifications INSTALLATION OPTIONSOperating Instructions FOR YOUR SAFETY READ BEFORELIGHTING INSTRUCTIONS PILOT LIGHTING INSTRUCTIONSNEVER USE AN OPEN FLAME FOR LEAK TESTING Operating InstructionsOperating Instructions TO TURN GAS FIREPLACE OFFMaintenance And Service ROUTINE MAINTENANCECLEANING THE GLASS CLEANING THE FIREBOXMaintenance And Service CLEANING DECORATIVE SURFACESGLASS DOOR REMOVAL Figure 8. Glass Removal HandleMaintenance And Service StepStep StepInitial Installation QUALIFIED INSTALLERS ONLYInitial Installation QUALIFIED INSTALLERS ONLYCORNER INSTALLATION Figure 11. Dimensions for a corner installationInitial Installation QUALIFIED INSTALLERS ONLYFIREPLACE SURROUND Figure 14. Raised Fireplace with Raised HearthQUALIFIED INSTALLERS ONLY Initial InstallationTop of unit to horizontal framing 12 5/16” 313 mm Initial Installation QUALIFIED INSTALLERS ONLYQUALIFIED INSTALLERS ONLY Initial Installationmm of clearance are necessary. See Figure Initial Installation QUALIFIED INSTALLERS ONLYVENT CONFIGURATIONS AND RESTRICTOR SETTINGS Figure 20. Possible Vent ConfigurationsQUALIFIED INSTALLERS ONLY Initial Installationthe possibility of a fire QUALIFIED INSTALLERS ONLY Initial InstallationStep 4. Assemble QUALIFIED INSTALLERS ONLY Initial InstallationSTEP 10. Twist-lockthe vent cap Initial Installation QUALIFIED INSTALLERS ONLYFigure 26 Multi-StoryVent Pipe Installation Figure 25 Use of Wall StrapsInitial Installation QUALIFIED INSTALLERS ONLYDUCTING Figure 27. Heat Dumping OptionsQUALIFIED INSTALLERS ONLY Initial InstallationELECTRICAL REQUIREMENTS NEVER USE AN OPEN FLAME FOR LEAK TESTING Initial InstallationGAS LINE CONNECTION TO TEST VALVE PRESSURESWARNING DO NOT INSTALL LINER IF UNIT IS HOT Secondary InstallationImportant installation notes Secondary Installation LOG SET ASSEMBLYFigure 35. First Stage Log Set Installation Figure 36. Second Stage Log Set InstallationSecondary Installation Figure 38. Fourth Stage Log Set InstallationFigure 39. Fifth Stage Log Set Installation Figure 40. Final Log Set ArrangementSecondary Installation Figure 42 The DV50DX burning with a good flameSecondary Installation screws and the control panelTroubleshooting ProblemSolution Possible CauseParts List - Components ReferenceDescription PartDV50DX - Components Parts DiagramNovember Options Parts List- OptionsPart Number TO THE DEALER WarrantyTO THE DISTRIBUTOR Installation Data Sheet