Secondary Installation

Secondary Installation

CERAMIC BRICK LINER REMOVAL:

WARNING: DO NOT INSTALL LINER IF UNIT IS HOT.

1.Remove glass door (see MAINTENANCE AND SERVICE - GLASS DOOR REMOVAL)

2.Carefully remove the log set if it was installed.

3.Remove both side brick liners by sliding them out the front. Be careful not to scrape the liners on the

baffle tabs at the top.

4.Hold the back of the top liner up while lifting the back liner off the air deflector ledge then out. Slide the top liner out from the lip on the baffle then remove it from the unit.

5.If the baffle needs to be removed use a T-20 screwdriver to loosen off but not remove the two (2) screws at the back of the baffle and remove the two (2) screws at the front of the baffle. Slide the baffle up over the back screws then out.

To install the liners follow steps 1 to 5 in reverse.

Important installation notes:

Ensuring the side brick liners are behind the baffle tabs and are flush against the firebox walls.

When sliding the baffle into place making sure to hook the back into place on the two loosened screws.

To install the log set follow the instruction in LOG

SET AND EMBER INSTALLATION.

LOG SET AND EMBER INSTALLATION:

Top Brick Liner

Baffle Lip

Baffle Tab

 

 

Back Brick Liner

Leftt Side

 

Brick Liner

Right Side Brick Liner

 

 

Air Deflector Ledge

For clarity unit is not shown.

Figure 33: Cast Iron Brick Liner Installation.

The placement of the logs is not arbitrary. If they are positioned incorrectly, the flames can be “pinched” and will not burn correctly. The burner (Figure 34) and a few of the logs come with locator pins, notches, and ledges which make alignment easier. The andirons and grate must be installed for the logs to be placed properly. Using the pictures provided, carefully set the logs in place (see Figures 35 through 41).

NOTE: The logs are fragile and should be handled gently.

Maintenance: Once a year the logs should be removed and checked for deterioration or large amounts of soot. A small amount on the bottom side of the

logs is normal. Remove and replace the logs in the same manner described in this section.

If new/more embers and rock wool is required, contact your nearest ENVIRO dealer.

Never operate the fireplace with the glass door removed.

Figure 34: This is how the fire box looks with only the andirons and grate in place. This points out the three ledges at the back and three locator pins on the burner.

Figure 34. Placement of ledges and pegs in empty

firebox.

26

Image 26
Contents Open windows/extinguish any open flame WHAT TO DO IF YOU SMELL GASDV50DX Do not try to light any applianceGENERAL Safety PrecautionsFOR YOUR SAFETY Table of Contents This ENVIRO DV50DX Fireplace Codes And ApprovalsVENTED GAS FIREPLACE HEATER DV50DX NG/LPG Specifications INSTALLATION OPTIONSLIGHTING INSTRUCTIONS Operating InstructionsFOR YOUR SAFETY READ BEFORE PILOT LIGHTING INSTRUCTIONSNEVER USE AN OPEN FLAME FOR LEAK TESTING Operating InstructionsOperating Instructions TO TURN GAS FIREPLACE OFFCLEANING THE GLASS Maintenance And ServiceROUTINE MAINTENANCE CLEANING THE FIREBOXGLASS DOOR REMOVAL Maintenance And ServiceCLEANING DECORATIVE SURFACES Figure 8. Glass Removal HandleStep Maintenance And ServiceStep StepInitial Installation QUALIFIED INSTALLERS ONLYCORNER INSTALLATION Initial InstallationQUALIFIED INSTALLERS ONLY Figure 11. Dimensions for a corner installationFIREPLACE SURROUND Initial InstallationQUALIFIED INSTALLERS ONLY Figure 14. Raised Fireplace with Raised HearthTop of unit to horizontal framing 12 5/16” 313 mm Initial InstallationQUALIFIED INSTALLERS ONLY Initial Installation QUALIFIED INSTALLERS ONLYmm of clearance are necessary. See Figure Initial InstallationQUALIFIED INSTALLERS ONLY VENT CONFIGURATIONS AND RESTRICTOR SETTINGS Initial InstallationQUALIFIED INSTALLERS ONLY Figure 20. Possible Vent Configurationsthe possibility of a fire Initial InstallationQUALIFIED INSTALLERS ONLY Step 4. Assemble Initial InstallationQUALIFIED INSTALLERS ONLY STEP 10. Twist-lockthe vent cap Initial InstallationQUALIFIED INSTALLERS ONLY Figure 26 Multi-StoryVent Pipe Installation Initial InstallationQUALIFIED INSTALLERS ONLY Figure 25 Use of Wall StrapsDUCTING Initial InstallationQUALIFIED INSTALLERS ONLY Figure 27. Heat Dumping OptionsELECTRICAL REQUIREMENTS Initial InstallationQUALIFIED INSTALLERS ONLY GAS LINE CONNECTION NEVER USE AN OPEN FLAME FOR LEAK TESTINGInitial Installation TO TEST VALVE PRESSURESImportant installation notes Secondary InstallationWARNING DO NOT INSTALL LINER IF UNIT IS HOT Figure 35. First Stage Log Set Installation Secondary InstallationLOG SET ASSEMBLY Figure 36. Second Stage Log Set InstallationFigure 39. Fifth Stage Log Set Installation Secondary InstallationFigure 38. Fourth Stage Log Set Installation Figure 40. Final Log Set ArrangementSecondary Installation Figure 42 The DV50DX burning with a good flameSecondary Installation screws and the control panelSolution TroubleshootingProblem Possible CauseDescription Parts List - ComponentsReference PartNovember Parts DiagramDV50DX - Components Part Number Parts List- OptionsOptions TO THE DISTRIBUTOR WarrantyTO THE DEALER Installation Data Sheet