Enviro DV50DX Maintenance And Service, Routine Maintenance, Cleaning The Glass, Replacing Glass

Page 9
Maintenance And Service

Maintenance And Service

ROUTINE MAINTENANCE:

At least once a year, run through the following procedures to ensure the system is clean and working properly. Check the burner to see if all the ports are clear and clean. Check the pilot to make sure it is not blocked by anything. The pilot flame should be blue with little or no yellow on the tips.

Warning: Clearances must be sufficient to allow access for maintenance and service

Warning: Failure to position the parts in accordance with this manual, or failure to use only parts specifically approved with this appliance may result in property damage or personal injury.

The venting system must be periodically examined; it is recommended the examination is done by a qualified agency.

CLEANING THE GLASS:

When the fireplace has cooled, remove the face of the fireplace along with the glass. See MAINTENANCE AND SERVICE - GLASS DOOR REMOVAL. Check the gasket material on the back of the glass, making sure that it is attached and intact.

During a cold start up, condensation will sometimes form on the glass. This is a normal condition with all fireplaces. However, this condensation can allow dust and lint to cling to the glass surface. Initial paint curing of the appliance can leave a slight film behind the glass, a temporary problem. The glass will need cleaning about two weeks after installation. Use a mild glass cleaner and a soft cloth; abrasive cleaners will damage the glass and plated surfaces. Depending on the amount of use, the glass should require cleaning no more than two or three times a season. Do not clean the glass when it is hot.

CLEANING THE FIREBOX:

Remove the logs carefully, as they are very fragile. Gently remove all the embers and rock wool and place on a paper towel. Vacuum the bottom of the firebox thoroughly. Carefully clean any dust off the logs and remove any lint from the burner and pilot. At this time, inspect the burner pan for cracking or severe warping. If a problem is suspected, contact the dealer. Check the logs for deterioration or large amounts of soot; a small amount on the bottom side of the logs is normal. Replace the logs and embers as in the LOG SET AND EMBER INSTALLATION section. If new/more embers and rock wool are required, contact your nearest ENVIRO dealer.

REPLACING GLASS:

The glass in the fireplace is a high temperature ceramic. If the glass is damaged in any way, a factory replacement is required (see PARTS LIST - COMPONENTS). Wear gloves when handling damaged glass door assembly to prevent personal injury. When the glass door assembly is being transported, it must be wrapped in newsprint and tape and/or a strong plastic bag. Do not operate with the glass front removed, cracked or broken. Removal and replacement of the glass from the door must be done by a licensed or qualified service person. The glass must be purchased from an ENVIRO dealer. No substitute materials are allowed.

9

Image 9
Contents DV50DX WHAT TO DO IF YOU SMELL GASOpen windows/extinguish any open flame Do not try to light any applianceSafety Precautions FOR YOUR SAFETYGENERAL Table of Contents Codes And Approvals VENTED GAS FIREPLACE HEATER DV50DX NG/LPGThis ENVIRO DV50DX Fireplace INSTALLATION OPTIONS SpecificationsFOR YOUR SAFETY READ BEFORE Operating InstructionsLIGHTING INSTRUCTIONS PILOT LIGHTING INSTRUCTIONSOperating Instructions NEVER USE AN OPEN FLAME FOR LEAK TESTINGTO TURN GAS FIREPLACE OFF Operating InstructionsROUTINE MAINTENANCE Maintenance And ServiceCLEANING THE GLASS CLEANING THE FIREBOXCLEANING DECORATIVE SURFACES Maintenance And ServiceGLASS DOOR REMOVAL Figure 8. Glass Removal HandleStep Maintenance And ServiceStep StepQUALIFIED INSTALLERS ONLY Initial InstallationQUALIFIED INSTALLERS ONLY Initial InstallationCORNER INSTALLATION Figure 11. Dimensions for a corner installationQUALIFIED INSTALLERS ONLY Initial InstallationFIREPLACE SURROUND Figure 14. Raised Fireplace with Raised HearthInitial Installation QUALIFIED INSTALLERS ONLYTop of unit to horizontal framing 12 5/16” 313 mm QUALIFIED INSTALLERS ONLY Initial InstallationInitial Installation QUALIFIED INSTALLERS ONLYmm of clearance are necessary. See Figure QUALIFIED INSTALLERS ONLY Initial InstallationVENT CONFIGURATIONS AND RESTRICTOR SETTINGS Figure 20. Possible Vent ConfigurationsInitial Installation QUALIFIED INSTALLERS ONLYthe possibility of a fire Initial Installation QUALIFIED INSTALLERS ONLYStep 4. Assemble Initial Installation QUALIFIED INSTALLERS ONLYSTEP 10. Twist-lockthe vent cap QUALIFIED INSTALLERS ONLY Initial InstallationFigure 26 Multi-StoryVent Pipe Installation Figure 25 Use of Wall StrapsQUALIFIED INSTALLERS ONLY Initial InstallationDUCTING Figure 27. Heat Dumping OptionsInitial Installation QUALIFIED INSTALLERS ONLYELECTRICAL REQUIREMENTS Initial Installation NEVER USE AN OPEN FLAME FOR LEAK TESTINGGAS LINE CONNECTION TO TEST VALVE PRESSURESSecondary Installation WARNING DO NOT INSTALL LINER IF UNIT IS HOTImportant installation notes LOG SET ASSEMBLY Secondary InstallationFigure 35. First Stage Log Set Installation Figure 36. Second Stage Log Set InstallationFigure 38. Fourth Stage Log Set Installation Secondary InstallationFigure 39. Fifth Stage Log Set Installation Figure 40. Final Log Set ArrangementFigure 42 The DV50DX burning with a good flame Secondary Installationscrews and the control panel Secondary InstallationProblem TroubleshootingSolution Possible CauseReference Parts List - ComponentsDescription PartParts Diagram DV50DX - ComponentsNovember Parts List- Options OptionsPart Number Warranty TO THE DEALERTO THE DISTRIBUTOR Installation Data Sheet