Regency E33-NG, E33-LP E33 Conversion KIT from NG to LPG, Conversion Kit Contains Qty

Page 12

INSTALLATION

03-19

Final Installation

E33 CONVERSION KIT FROM NG TO LPG

THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER

IF IN DOUBT DO NOT DO THIS CONVERSION !!

Conversion Kit Contains:

Qty. Part #

Description

1910-018 SIT Conversion Kit-50% Turndown LPG

1910-037 LPG (Pilot Orifi ce)

1904-641 Burner Orifi ce #50

(rated at 35,500 BTU/HR)

1908-255 Label "Converted to LPG"

1904-529 5/32" Allen Key

1918-415 Instruction Sheet

1Red LPG Label

1Silver "Converted to

LPG" Label

Instructions:

1)Shut off the gas supply.

2)Remove the louvers and fl ush door.

3)Remove the logs and grate (refer to p.10). Ensure you slide the bottom log 03-17 off to the right-hand side to avoid chipping.

4)Remove front base brick.

5)Remove burner by unscrewing the 2 screws.

6)Pull off the pilot cap to expose the pilot orifi ce.

7)Unscrew the pilot orifi ce with the allen key and replace with the LPG pilot orifi ce provided in the kit, then replace pilot cap.

8)Remove the burner orifi ce by using a 1/2" wrench, while using a 9/16" wrench to hold onto the elbow behind the orifi ce.

Burner Orifice Removal

9)Reinstall new burner orifi ce LPG stamped #50 and tighten.

10)Remove and discard the 3 pres- sure regulator mounting screws (A), pressure regulator (B) and diaphragm (C) refer to Diagram 1.

11)Ensure that the rubber gasket (D) is properly positioned. Install the new HI/LO pressure regulator assembly to the valve using the new screws (E) supplied with the kit.Tighten screws securely.

12)Reverse steps 5) to 3).

13)Attach clear label "This unit has been converted to LPG" near or on the serial # decal. Attach silver label "This valve has been converted from NG to LPG using SIT conversion Kit Code 0.907.202" onto the valve.

14)Replace yellow "NG" label with red "LPG" label.

15)Check for gas leaks with a proper soapy solution or leak detector.

16)Check for proper spark between the ignitor and pilot cap. Refer to “Lighting Procedure” (page 18) for lighting sequence.

17)Check pilot fl ames. Correct fl ame pattern has 3 strong blue fl ames. Adjustment can be made by turning the slotted screw at the top right corner of the valve. Refer to

12

E33 FPI Direct Vent Gas Insert

Image 12
Contents E33 Gas Insert 08/16/05FPI GAS Fireplace Insert E33 FPI Direct Vent Gas InsertTable of Contents Safety Label Installation Installation Checklist Minimum Fireplace OpeningMaterials Required Minimum Fireplace Opening Excalibur OptionMinimum Clearances to Combustibles Flue Liner Installation GAS ConnectionVenting Pressure Testing DiagramGAS Pipe Optional Brick PanelLOG Installation Final Installation03-23 03-22 03-18 03-24 03-20 03-19 03-17Locating Pins Locating Pins 03-2003-23 03-20 Locating Pins 03-24 03-23 Locating Pins 03-21E33 Conversion KIT from NG to LPG Conversion Kit Contains QtyShut off the gas supply Remove the louvers and fl ush door Burner Orifice RemovalFaceplate & Trim Installation Pilot Adjustment ScrewRear View Faceplate Assembly Diagram Rear View Trim Assembly DiagramFlush Louvers Standard Flush DoorFull Screen Front To remove the fl ush door, reverse the above stepsInstall Spring Hinges to the Left and Right Side of the bottom of the fi rebox usingOrder to make the following wire connec Rebox and connect them to the switchAccent KIT Installation Attach door bracket to sides using 4 screwsOptional Screen Doors Double Screen Door attach to left and right side of unitWiring Diagram Optional Remote Control Optional WallThermostat Operating Instructions Copy of Lighting Instruction Plate Normal Operating Sounds GAS AppliancesMaintenance FAN Maintenance Straighten adjustment wireFan Access Plate Screws Door GlassValve Assembly Rebox and from the valve access plateInstall new gasket and valve assembly Replacing fanParts List Main AssemblyBurner & LOG Assembly Valve TrayBurner Assy NG/LP Burner Grate AssyFull Screen Front Installation FACEPLATES, Trims and Hearths E33 FPI Direct Vent Gas Insert E33 FPI Direct Vent Gas Insert E33 FPI Direct Vent Gas Insert E33 FPI Direct Vent Gas Insert Warranty ConditionsInstaller Please complete the following information E33 FPI Direct Vent Gas Insert