Regency E33-LP, E33-NG Copy of Lighting Instruction Plate, Normal Operating Sounds GAS Appliances

Page 19

OPERATING INSTRUCTIONS

COPY OF LIGHTING INSTRUCTION PLATE

AUTOMATIC

 

CONVECTION

 

FAN OPERATION

 

The fan operates automatically.Turn the knob on

 

the side of the faceplate to adjust to the desired

 

speed. The fan will turn on as the stove comes

 

up to operating temperature. After the unit has

 

been turned off and the unit has been cooled

 

to below useful heat output range, the fan will

 

shut off automatically.

NORMAL OPERATING

SOUNDS OF

GAS APPLIANCES

It is possible that you will hear some sounds from your gas appliance.This is perfectly normal due to the fact that there are various gauges and types of steel used within your appliance. Listed below are some examples.All are normal operatingsoundsandshouldnotbeconsidered as defects in your appliance.

Blower:

FPI gas appliances use high tech blowers to push heated air farther into the room. It is not unusual for the fan to make a "whirring" sound when ON. This sound will increase or decrease in volume depending on the speed setting of your fan speed control.

Burner Tray:

The burner tray is positioned directly under the burner tube(s) and logs and is made of a differ- ent gauge material from the rest of the fi rebox and body. Therefore, the varying thicknesses of steel will expand and contract at slightly different rates which can cause "ticking" and "cracking" sounds. You should also be aware that as there are temperature changes within the unit. These sounds will likely re-occur. Again, this is normal for steel fi reboxes.

Blower Thermodisc:

When thermally activated switch turns ON, it will create a small "clicking" sound. This is the contact switch closing.

Pilot Flame:

While the pilot fl ame is on it will make a slight "whisper" sound.

Gas Control Valve:

As the gas control valve turns ON and OFF, a dull clicking sound may be heard. This is normal operation of a gas regulator or valve.

Unit Body and Firebox:

Different types and thicknesses of steel will ex- pand and contract at different rates resulting in some "cracking" and "ticking" sounds which will be heard throughout the cycling process.

E33 FPI Direct Vent Gas Insert

19

 

Image 19
Contents 08/16/05 E33 Gas InsertE33 FPI Direct Vent Gas Insert FPI GAS Fireplace InsertTable of Contents Safety Label Installation Minimum Fireplace Opening Excalibur Option Installation ChecklistMinimum Fireplace Opening Materials RequiredMinimum Clearances to Combustibles GAS Connection Flue Liner InstallationVenting Optional Brick Panel Pressure TestingDiagram GAS Pipe03-22 03-18 03-24 03-20 03-19 03-17 LOG InstallationFinal Installation 03-2303-24 03-23 Locating Pins 03-21 Locating PinsLocating Pins 03-20 03-23 03-20 Locating PinsBurner Orifice Removal E33 Conversion KIT from NG to LPGConversion Kit Contains Qty Shut off the gas supply Remove the louvers and fl ush doorRear View Trim Assembly Diagram Faceplate & Trim InstallationPilot Adjustment Screw Rear View Faceplate Assembly DiagramTo remove the fl ush door, reverse the above steps Flush LouversStandard Flush Door Full Screen FrontRebox and connect them to the switch Install Spring Hinges to the Left and RightSide of the bottom of the fi rebox using Order to make the following wire connecDouble Screen Door attach to left and right side of unit Accent KIT InstallationAttach door bracket to sides using 4 screws Optional Screen DoorsOptional Remote Control Optional Wall Wiring DiagramThermostat Operating Instructions Normal Operating Sounds GAS Appliances Copy of Lighting Instruction PlateMaintenance Door Glass FAN MaintenanceStraighten adjustment wire Fan Access Plate ScrewsReplacing fan Valve AssemblyRebox and from the valve access plate Install new gasket and valve assemblyMain Assembly Parts ListBurner Grate Assy Burner & LOG AssemblyValve Tray Burner Assy NG/LPFull Screen Front Installation FACEPLATES, Trims and Hearths E33 FPI Direct Vent Gas Insert E33 FPI Direct Vent Gas Insert E33 FPI Direct Vent Gas Insert E33 FPI Direct Vent Gas Insert Conditions WarrantyE33 FPI Direct Vent Gas Insert Installer Please complete the following information