OPERATING INSTRUCTIONS
Thermostat Wire Table
Recommended Maximum Lead Length
Thermostat
Wire Size | Max. Length | |
14 GA. | 50 | Ft. |
16 GA. | 32 | Ft. |
18 GA. | 20 | Ft. |
20 GA. | 12 | Ft. |
22 GA. | 9 | Ft. |
|
|
|
|
|
|
FINAL CHECK
DO NOT BURN THE APPLIANCE WITHOUT THE GLASS FRONT IN PLACE.
During the first few fires, a white film may develop on the glass front as part of the curing process. The glass should be cleaned or the film will bake on and become very difficult to remove. Use a
OPERATING
INSTRUCTIONS
2) | Turn gas control knob so indicator points |
| to "OFF" position and allow 5 minutes for |
| any gas in the combustion chamber to |
| escape. |
3) | Turn gas control knob counterclockwise |
| so indicator points to the "PILOT" position. |
| Depress the gas control knob fully. Depress |
| the ignitor button several times until the |
| pilot lights. After approximately one minute, |
| release the gas control knob. The pilot fl ame |
| should continue to burn. If the pilot does not |
| remain lit, repeat operation allowing a longer |
| period before releasing gas control knob. |
4) | When the pilot stays lit, turn the gas knob |
| further counterclockwise to the "ON" posi- |
| tion. |
5) | Reinstall the glass door (refer to page 14). |
Before leaving this unit with the customer, the installer must ensure that the appliance is fi ring correctly. This includes:
1)Clocking the appliance to ensure the cor- rect fi ring rate (rate noted on label) at 15 minutes.
2)Ifrequired,adjustingtheprimaryairtoensure that the fl ame does not carbon. First allow the unit to burn for 15 min. to stabilize.
3)Check for proper draft.
CAUTION
Any alteration to the product that causes sooting or carboning that results in damage to the exterior facia is not the responsibility of the manufacturer.
FIRST FIRE
The fi rst fi re in your stove is part of the paint curing process. To ensure that the paint is properly cured, it is recommended that you burn your fi replace for at least four (4) hours the fi rst time you use it with the fan on. When
first operated, the unit will release an odour caused by the curing of the paint, the burning off of any oils remaining from manufacturing. Smoke detectors in the house may go off at this time. Open a few windows to ventilate the room for a couple of hours.
The glass panel may require cleaning after the unit has cooled down.
DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS HOT.
Note: When the glass is cold and the appli- anceislit,itmaycausecondensation and fog the glass. This condensation is normal and will disappear in a few minutes as the glass heats up.
1)Read and understand these instructions before operating this appliance.
2)Check to see that all wiring is correct and enclosed to prevent possible shock.
3)Check to ensure there are no gas leaks.
4)Make sure the glass in the door frame is properly positioned. Never operate the ap- pliance with the glass removed.
5)Verify that the venting and cap are unob- structed.
6)Ensure that the brick panels, if used, are installed.
7)Verify log placement. If the pilot cannot be seen when lighting the unit, the logs have been incorrectly positioned.
8)The unit should never be turned off, and on again without a minimum of a 60 second wait.
LIGHTING
PROCEDURE
IMPORTANT
Prior to igniting or reigniting the
pilot, remove the glass door.
Only when the pilot holds, without pressure being applied to the control knob, should you reinstall the glass door. The unit must not be operated with the glass door removed.
IMPORTANT: Gas cock knob cannot be turned from "PILOT" to "OFF" unless it is partially depressed.
1)Turn burner OFF using "ON/OFF" switch.
6) | Use the switch, thermostat or remote control |
| to turn on the unit. |
7) | Rotate the fl ame height regulator to adjust |
| the fl ame height higher or lower. |
SHUTDOWN
PROCEDURE
1)Use the switch, thermostat or remote control to turn off the main burner.
2)Turn the main gas control clockwise to the "OFF" position to turn off the pilot.
3)Turn off all electric power to appliance if service is to be performed.
18 | E33 FPI Direct Vent Gas Insert |