Regency E33-NG, E33-LP Valve Assembly, Rebox and from the valve access plate, Replacing fan

Page 22

MAINTENANCE

13)Pull Fan Assembly forward, to disengage the fan clip on the rear wall. Then lift the Fan Assembly up and pull through fi rebox opening.

7)Remove base brick set. (When removing base brick sides the two screws that hold the grate down must be removed fi rst).

Screws

8)Straighten the adjustment wire under the fi rebox base.

11)Disconnect the inlet gas line.

12)Unplug the black and red wires at the valve. Undo the 2 TP wires at the valve.

13)Remove the 17 screws on the valve tray.

14)Take out the valve tray from the unit.

Air Shutter Wire

14)Disconnect green wire from power cord.

Straighten adjustment wire.

9) Remove the Burner by removing the 2 screws (1 on burner bracket and one on valve tray). Tilt up the left burner and slide to the left away from the orifi ce.

15)

Scrape off the old gasket from the floor of the

 

fi rebox and from the valve access plate.

16)

Install new gasket and valve assembly

Replacing fan:

15)Reverse above steps.

Sealfanaccesspanelusinghightemperature silicone (sparingly).

VALVE ASSEMBLY

REMOVAL AND INSTALLATION

1)Turn the unit off and allow it to cool down to room temperature.

2)Unplug or disconnect power source.

3)Shut off the main gas supply.

4)Remove the louvers and glass door (refer to page 14).

5)Remove logs and grate (refer to page 10).

6)Remove optional brick set, if installed (refer to page 9).

Screws

10)Remove the rear log support by unscrewing the 2 screws.

Screws

(reverse steps 9-14).

NOTE: Failure to install a new gasket may severely affect the appliance perfor- mance.

17)Hook up gas line and check for gas leaks with soap and water solution or a gas leak detector. Do not use open flame for leak testing.

18)Set up the air shutter to 5/16" for NG and 7/16" for LP.

19)Fire up the unit temporarily.

20)Check the manifold pressure 3.8" W.C. for NG and 11" W.C. for LP.

21)Reverse steps 4-8.

22

E33 FPI Direct Vent Gas Insert

Image 22
Contents E33 Gas Insert 08/16/05FPI GAS Fireplace Insert E33 FPI Direct Vent Gas InsertTable of Contents Safety Label Installation Materials Required Installation ChecklistMinimum Fireplace Opening Minimum Fireplace Opening Excalibur OptionMinimum Clearances to Combustibles GAS Connection Flue Liner InstallationVenting GAS Pipe Pressure TestingDiagram Optional Brick Panel03-23 LOG InstallationFinal Installation 03-22 03-18 03-24 03-20 03-19 03-1703-23 03-20 Locating Pins Locating PinsLocating Pins 03-20 03-24 03-23 Locating Pins 03-21Shut off the gas supply Remove the louvers and fl ush door E33 Conversion KIT from NG to LPGConversion Kit Contains Qty Burner Orifice RemovalRear View Faceplate Assembly Diagram Faceplate & Trim InstallationPilot Adjustment Screw Rear View Trim Assembly DiagramFull Screen Front Flush LouversStandard Flush Door To remove the fl ush door, reverse the above stepsOrder to make the following wire connec Install Spring Hinges to the Left and RightSide of the bottom of the fi rebox using Rebox and connect them to the switchOptional Screen Doors Accent KIT InstallationAttach door bracket to sides using 4 screws Double Screen Door attach to left and right side of unitOptional Remote Control Optional Wall Wiring DiagramThermostat Operating Instructions Copy of Lighting Instruction Plate Normal Operating Sounds GAS AppliancesMaintenance Fan Access Plate Screws FAN MaintenanceStraighten adjustment wire Door GlassInstall new gasket and valve assembly Valve AssemblyRebox and from the valve access plate Replacing fanParts List Main AssemblyBurner Assy NG/LP Burner & LOG AssemblyValve Tray Burner Grate AssyFull Screen Front Installation FACEPLATES, Trims and Hearths E33 FPI Direct Vent Gas Insert E33 FPI Direct Vent Gas Insert E33 FPI Direct Vent Gas Insert E33 FPI Direct Vent Gas Insert Warranty ConditionsInstaller Please complete the following information E33 FPI Direct Vent Gas Insert