INSTALLATION
11)Due to high temperatures, the appliance should be located out of high traffic areas and away from furniture and draperies. Children and adults should be alerted to the hazards of high surface temperatures, especially the fi replace glass, and should stay away to avoid burns or clothing ignition. Young children should be carefully super- vised when they are in the same room as the appliance. Clothing or other fl ammable material should not be placed on or near the appliance.
Emissions from burning wood or gas could contain chemicals known to the State of Cali- fornia to cause cancer, birth defects or other reproductive harm.
14)Install optional Excalibur Surround. See page 15.
15)Install optional remote control or wall ther- mostat, pages 17.
16)Final check (page 18): Before leaving this unit with the customer, the installer must ensure that the appliance is fi ring correctly. This includes:
a)Clocking the appliance to ensure the correct fi ring rate.
b)Adjusting the primary air, if required, to ensure that the fl ame does not carbon. See page 9.
c)Ensuring that the appliance is venting correctly.
MINIMUM FIREPLACE
OPENING
The minimum fi replace opening for the FPI gas fi replace insert is shown in the following diagrams:
INSTALLATION
CHECKLIST
Before installing vent system ensure that the damper plate is open and secure to prevent the damper plate from falling down and crush- ing the liner.
The FPI Gas Insert is installed as listed below.
1)Check all clearances to combustibles, see page 7.
2)Make the gas connection. See page 8.
3)Installthe3"fluelinertotheslidingconnector plate. See page 8.
4)Slide the unit half way into the fi replace.
5)Pull the vent connector plate through the tapered brackets and fasten to the front plate. See page 8.
6)Slide the unit fully into the fi replace.
7)Test gas pressure, page 9. Check aeration system, page 9.
8)Install the optional brick panels. See page 9.
9)Install the log set. See page 10.
10)Assemble and install the faceplate and trim. See page 13.
11)Install the standard fl ush door. See page 14.
12)Install both louvers. See page 14.
13)Install optional full screen doors. See page 16.
MATERIALS
REQUIRED
No electrical power supply is required for the gas control to operate. A 120 Volt AC power cord is hooked up to the fan. Plug the 3 wire cord into a suitable receptacle. Do not cut the ground terminal off under any circumstances. When connected with 120 volts, the appliance must be electrically grounded in accordance with local codes, current version of the Canadian Electrical Code CSA C22.1 (in Canada) or in the absence of local codes, with the National Electrical Code ANSI/NFPA 70.
NOTE: This unit is equipped with a heat sensor thermodisc which will prevent the blower from operating until the unit reaches the correct temperature.
WARNING:
Electrical Grounding Instructions This appliance is equipped with a three pronged (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded
MINIMUM FIREPLACE OPENING EXCALIBUR OPTION
The minimum fi replace opening for the FPI gas fi replace insert is shown in the following diagrams:
NOTE: If you are installing the Excali- bur,theminimum fireplacedimensions are as follows:
Width (at front): |
| ||||||||||||||||||||
Depth: |
| ||||||||||||||||||||
Height: | 26" |
|
|
|
| (660mm) | |||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
6 | E33 FPI Direct Vent Gas Insert |