MAINTENANCE
DOOR GLASS
Your FPI stove is supplied with high temperature, 5mmNeoceramceramicglassthatwillwithstand the highest heat that your unit will produce. Do not abuse the glass by striking the surface or by slamming the door shut.
If your glass requires cleaning, we recommend using an approved glass cleaner available at all authorized dealers. Do not use abrasive mate- rials. Do not clean the glass when hot.
In the event that you break your glass by impact, purchase your replacement from an authorized FPI dealer only, do not use substitute materials. Follow our
Caution: Do not operate appliance with glass panels removed, cracked or broken. Replacement of the glass should be done by a licensed or qualified service person.
Flush Glass Replacement
Remove the fl ush door front (refer to page 14). Remove the 4 glass clips from each corner. Slide in the new replacement glass. Push the 4 glass clips back onto the frame.
To Remove Fan:
1)Turn the unit off and allow it to cool down to room temperature.
2)Unplug or disconnect power source to stove.
3)Remove the fl ush door (refer to p.14).
4)Remove logs and grate (refer to p.10).
5)Remove optional brick panel set, if installed (refer to page 9).
6)Remove base brick set. (When removing base brick sides the two screws that hold the grate down must be removed fi rst).
Screws
7)Straighten the adjustment wire under the fi rebox base.
Air Shutter Wire
Straighten adjustment wire.
8)Remove the Burner by removing the 2 screws (1 on burner bracket and one on valve tray). Tilt up the left burner and slide to the left away from the orifi ce.
9)Remove the rear log support by unscrewing the 2 screws.
Screws
10)Remove the 12 screws holding the Access Panel in place.
Fan Access Plate Screws
11)Unplug the wires from the fan motor (from inside the stove).
12)Remove the 2 screws from the fan bracket.
FAN MAINTENANCE
If your fan requires maintenance or replace- | Screws | |
ment, access to the fan is through the plate on |
| |
the fl oor of the fi rebox. NOTE: the unit MUST | Screws | |
NOT be operated without the fan access | ||
| ||
panel securely in place. |
|
Caution: Label all wires prior to discon- nectingwhenservicingcontrols.Wiring errors can cause improper and danger- ous operation. Verify proper operation after servicing.
E33 FPI Direct Vent Gas Insert | 21 |
|