MAINTENANCE

DOOR GLASS

Your FPI stove is supplied with high temperature, 5mmNeoceramceramicglassthatwillwithstand the highest heat that your unit will produce. Do not abuse the glass by striking the surface or by slamming the door shut.

If your glass requires cleaning, we recommend using an approved glass cleaner available at all authorized dealers. Do not use abrasive mate- rials. Do not clean the glass when hot.

In the event that you break your glass by impact, purchase your replacement from an authorized FPI dealer only, do not use substitute materials. Follow our step-by-step instructions for replace- ment. Warning: Wear gloves when removing damaged or broken glass.

Caution: Do not operate appliance with glass panels removed, cracked or broken. Replacement of the glass should be done by a licensed or qualified service person.

Flush Glass Replacement

Remove the fl ush door front (refer to page 14). Remove the 4 glass clips from each corner. Slide in the new replacement glass. Push the 4 glass clips back onto the frame.

To Remove Fan:

1)Turn the unit off and allow it to cool down to room temperature.

2)Unplug or disconnect power source to stove.

3)Remove the fl ush door (refer to p.14).

4)Remove logs and grate (refer to p.10).

5)Remove optional brick panel set, if installed (refer to page 9).

6)Remove base brick set. (When removing base brick sides the two screws that hold the grate down must be removed fi rst).

Screws

7)Straighten the adjustment wire under the fi rebox base.

Air Shutter Wire

Straighten adjustment wire.

8)Remove the Burner by removing the 2 screws (1 on burner bracket and one on valve tray). Tilt up the left burner and slide to the left away from the orifi ce.

9)Remove the rear log support by unscrewing the 2 screws.

Screws

10)Remove the 12 screws holding the Access Panel in place.

Fan Access Plate Screws

11)Unplug the wires from the fan motor (from inside the stove).

12)Remove the 2 screws from the fan bracket.

FAN MAINTENANCE

If your fan requires maintenance or replace-

Screws

ment, access to the fan is through the plate on

 

the fl oor of the fi rebox. NOTE: the unit MUST

Screws

NOT be operated without the fan access

 

panel securely in place.

 

Caution: Label all wires prior to discon- nectingwhenservicingcontrols.Wiring errors can cause improper and danger- ous operation. Verify proper operation after servicing.

E33 FPI Direct Vent Gas Insert

21

 

Image 21
Contents 08/16/05 E33 Gas InsertE33 FPI Direct Vent Gas Insert FPI GAS Fireplace InsertTable of Contents Safety Label Installation Minimum Fireplace Opening Installation ChecklistMaterials Required Minimum Fireplace Opening Excalibur OptionMinimum Clearances to Combustibles Flue Liner Installation GAS ConnectionVenting Diagram Pressure TestingGAS Pipe Optional Brick PanelFinal Installation LOG Installation03-23 03-22 03-18 03-24 03-20 03-19 03-17Locating Pins 03-20 Locating Pins03-23 03-20 Locating Pins 03-24 03-23 Locating Pins 03-21Conversion Kit Contains Qty E33 Conversion KIT from NG to LPGShut off the gas supply Remove the louvers and fl ush door Burner Orifice RemovalPilot Adjustment Screw Faceplate & Trim InstallationRear View Faceplate Assembly Diagram Rear View Trim Assembly DiagramStandard Flush Door Flush LouversFull Screen Front To remove the fl ush door, reverse the above stepsSide of the bottom of the fi rebox using Install Spring Hinges to the Left and RightOrder to make the following wire connec Rebox and connect them to the switchAttach door bracket to sides using 4 screws Accent KIT InstallationOptional Screen Doors Double Screen Door attach to left and right side of unitWiring Diagram Optional Remote Control Optional WallThermostat Operating Instructions Normal Operating Sounds GAS Appliances Copy of Lighting Instruction PlateMaintenance Straighten adjustment wire FAN MaintenanceFan Access Plate Screws Door GlassRebox and from the valve access plate Valve AssemblyInstall new gasket and valve assembly Replacing fanMain Assembly Parts ListValve Tray Burner & LOG AssemblyBurner Assy NG/LP Burner Grate AssyFull Screen Front Installation FACEPLATES, Trims and Hearths E33 FPI Direct Vent Gas Insert E33 FPI Direct Vent Gas Insert E33 FPI Direct Vent Gas Insert E33 FPI Direct Vent Gas Insert Conditions WarrantyE33 FPI Direct Vent Gas Insert Installer Please complete the following information