Regency U39-NG1, U39-LP1 Installation Precautions Rigid Pipe Venting Arrangements

Page 13

INSTALLATION

INSTALLATION PRECAUTIONS

RIGID PIPE VENTING ARRANGEMENTS

These venting systems are engineered products that have been designed and tested for use with the U39-NG1, and U39-LP1. The warranty will be voided and serious fi re, health or other safety hazardsmayresultfromanyofthefollowing actions:

1)Installation ofanydamaged Direct Vent component

2)Unauthorized modification of the Direct Vent System

3)Installation of any component part not manufactured orapprovedbySimpson Dura-Vent or Fireplace Products International Ltd.

4)Installation other than as instructed by Simpson Dura-Vent and Fireplace Products International Ltd.

Horizontal Terminations for All

Venting Systems

The shaded areas in the diagram below show all allowable combinations of vertical runs with horizontal terminations. Maximum one 90O elbow (two 45o elbows equal one 90o elbow).

Propane and Natural Gas:

Residential, Manufactured and

Mobile Homes Installations

The venting arrangements diagrammed below, have a min. of 75% (fl ue loss) efficiency with Fan Off, as required for manufactured homes. (Actual efficiency may be as high as 85%)

May be installed in Manufactured (Mobile)

Homes after fi rst sale.

Vertical Termination Systems for Residential Manufactured and Mobile Homes

The shaded area in the diagram below shows all allowable combinations of straight vertical and offset to vertical runs with vertical terminations. Maximum two 45o elbows.

If the vent is ENCLOSED in a chase (min. size 9" x 9") maintain a 1-1/4" clearance to combustibles.

May be installed in Manufactured (Mobile)

Homes after fi rst sale.

Warning: Always maintain requiredclearances(airspaces)

to nearby combustibles to prevent a fire hazard. Do not fill air spaces with insulation.

Be sure to check the vent termination clearance requirements from decks, windows, soffits, gas regulators, air supply inlets and public walkways as specifi ed in the "Exterior Vent Terminal Locations" section in your local building codes.

The gas appliance and vent system must be vented directly to the outside of the building, and never be attached to a chimney serving a separate solid fuel or gas-burning appliance. Each direct vent gas appliance must use it's own separate vent system. Common vent systems are prohibited.

SAFETY

PRECAUTIONS FOR

THE INSTALLER

1)Wear gloves and safety glasses for protection.

2)Exercise extreme caution when using ladders or on roof tops.

3)Be aware of electrical wiring locations in walls and ceilings.

Vent Restrictor Position

To set the Vent restriction as indicated in the diagram, simply loosen the screws and push the vent restrictor plate to the correct position. Tighten the screws.

Vent Restrictor setting at

38,000 Btu/h

Vent Restrictor setting at

30,000 Btu/h

Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove

13

Image 13
Contents Ultimate U39 Regency Table of Contents Copy of Safety Label for U39 Gas Stove Safety LabelMA Code CO Detector RequirementsSpecifications InstallationImportant Message Save These Instructions Before YOU StartGeneral Safety Information Installation ChecklistClearances to Combustibles Venting Introduction Louver InstallationManufactured Mobile Home Additional Requirements Locating Your Ultimate GAS StoveExterior Vent Terminal Description 6-5/8 Rigid Pipe Cross Reference Chart6-5/8 Rigid Pipe Cross Reference Chart Alternate Rigid Pipe Venting SystemsMination Caps Safety Precautions for Installer Installation Precautions Rigid Pipe Venting ArrangementsHorizontal Terminations for All Venting Systems Vent Restrictor PositionVertical Venting with Two 2 90o Elbows Horizontal Venting with Two 2 90o ElbowsDV Stove Horizontal Vent KIT Installation Capcanbemounted on Minimum components for a Dura-Vent Horizontal Installation Planning Your Dura-Vent InstallationDURA-VENT Termination KIT DURA-VENT Venting ComponentsSnorkel Terminations DURA-VENT Horizontal TerminationsDURA-VENT Vertical Terminations Below Grade InstallationCathedral Ceilings Offset ChartSupport Extensions Round Rdse or Square Sqse Approved for US Installations OnlyGeneral Converting a Factory Built Metal ChimneyConverting a Masonry Chimney High Elevation GAS ConnectionSystem Data U39 with 40,000 BTU System DataLPG Conversion Kit Contains Qty Conversion KIT# 731-969 from NG to LPOnly Required for the U38 Green ground wire Conversion to Lower BTU Rating GAS Pipe Pressure TestingNatural Gas Conversion Kit 730-920 Contains Propane Conversion Kit 730-922 ContainsValve Description Aeration AdjustmentU39 with 38,000 Btu/h U39 with 30,000 Btu/hLOG SET Installation B02-56 E02-45 G02 A02-65 Wiring Diagram 14 GA 16 GA 18 GA 20 GA 22 GA Final CheckOperating Instructions Lighting ProcedureOperating Instructions Shutdown InstructionsAutomatic Convection FAN Operation Normal Operating Sounds GAS AppliancesCopy Of Lighting Plate Instructions Maintenance Instructions MaintenanceGeneral Vent Maintenance GOLD-PLATED DoorsLatch Adjustment LOG ReplacementGlass Replacement Door GasketDC Sparker Battery Replacement FAN MaintenanceAlternate Fan Access To Remove U39 FanRemoving Valve Main Assembly Parts ListDescription Burner & LOG Assembly Door Assemblies Conditions WarrantyInstaller Please complete the following information

U39-LP1, U39-NG1 specifications

The Regency U39-LP1 and U39-NG1 are innovative heating appliances designed for modern homes, emphasizing both efficiency and style. These units encapsulate the essence of contemporary design while ensuring high-performance heating solutions. The U39 series stands out for its user-friendly features and advanced technologies that cater to the demands of varied environments.

One of the main features of the U39-LP1 is its propane-fueled operation, allowing it to generate an impressive amount of heat while remaining energy-efficient. The unit is designed with a remarkable heating capacity, making it ideal for larger spaces or for those chilly evenings where comfort is paramount. In contrast, the U39-NG1 operates on natural gas, appealing to homeowners looking for a more sustainable option. Both models allow for quick and effective heating, ensuring a cozy atmosphere within moments.

The technology embedded in both models reflects a commitment to top-tier performance. The advanced electronic ignition system provides reliability, ensuring seamless operation. The units also incorporate a built-in thermostat, which allows for precise control over the temperature, enhancing comfort while conserving energy. Furthermore, the U39 series features a sleek ceramic glass front that not only adds an aesthetic element but also enhances efficiency by radiating heat effectively into the room.

Another hallmark of the Regency U39 series is its design versatility. Both models are available in various finishes, enabling them to blend seamlessly into different décor styles, whether traditional, modern, or minimalist. The compact dimensions of these units ensure they fit effortlessly into a variety of spaces, from living rooms to basements.

Safety is also a significant focus with the U39-LP1 and U39-NG1. The units come equipped with a variety of safety features, including automatic shut-off and heat-resistant materials, ensuring peace of mind for users.

In summary, the Regency U39-LP1 and U39-NG1 models exemplify modern heating solutions characterized by efficiency, advanced technology, and stylish design. With their user-centric features and commitment to safety, these units are perfect additions for anyone seeking warmth and comfort in their homes. Whether powered by propane or natural gas, the U39 series continues to redefine the standard for home heating.