Regency U39-NG1, U39-LP1 DURA-VENT Vertical Terminations, Below Grade Installation

Page 19

INSTALLATION

Below Grade Installation

If the Snorkel Termination must be installed below grade, i.e. basement application, proper drainagemustbeprovidedtopreventwaterfrom entering the Snorkel Termination. Refer to Dia.

4.Do not attempt to enclose the Snorkel within the wall, or any other type of enclosure.

Diagram 4

4)If installing the vent termination to a wall with vinyl siding, the Vinyl Siding Standoff must be used. Attach the Vinyl Siding Standoff to the Horizontal VentTermination, but first run a bead of non-hardening mastic around its outsideedges,soastomakeasealbetween vent cap and the standoff. Install the Vinyl Siding Standoff (Part # 950) between the vent cap and the exterior wall and attach with the four wood screws provided. Seal around the Vinyl Siding Standoff on all four sides. Diagram 5. The arrow on the vent cap should be pointing up. Insure that the 1-1/4" clearances to combustible materials are maintained. See diagram 5.

Note:

If installing termination on a siding

 

covered wall, a vinyl siding standoff

 

or furring strips must be used to

 

ensure that the termination is not

 

recessed into the siding. The four

 

wood screws provided should be

 

replaced with appropriate fasteners

 

for stucco, brick, concrete, or other

 

types of sidings.

5)Before connecting the horizontal run of vent pipe to the vent termination, slide the black decorative wall thimble cover over the vent pipe, then slide the Wall Thimble (Part # 942) over the vent pipe.

6)Slide the appliance and vent assembly towards the wall carefully inserting the vent pipe into the vent cap assembly. It is important that the vent pipe extends into the vent cap a sufficient distance so as to result in a minimum pipe overlap of 1-1/4 inches. Secure the connection between the vent pipe and the vent cap by attaching the two sheet metal strips extending from the vent cap assembly into the outer wall of the vent pipe. Use the two sheet metal screws provided to connect the strips to the pipe. Bend any remaining portion of the sheet metal strip back towards the vent cap, so it will be concealed by the decorative wall thimble cover. See diagram 6.

Diagram 6

DURA-VENT VERTICAL

TERMINATIONS

1) Maintain the 1 - 1/4" clearances (air spaces) to combustibleswhenpassing through ceilings, walls, roofs, enclosures, attic rafter, or other nearby combustible surfaces. Do not pack air spaces with insulation. Check the "Rigid Pipe Venting Arrangments" section for themaximumverticalriseof the venting system and the maximum horizontal offset limitations.

2)Set the gas appliance

in its desired location. Drop a plumb bob down

from the ceiling to the

 

position of the appliance

 

fl ue exit, and mark the

 

location where the vent

 

will penetrate the ceiling.

Diagram 8

Drill a small hole at his point. Next, drop a plumbbobfromtherooftotheholepreviously drilled in the ceiling, and mark the spot where the vent will penetrate the roof. Determine if ceiling joists, roof rafters or other framing will obstruct the venting system. You may wish to relocate the appliance or to offset, as shown in diagram 9 to avoid cutting load bearing members.

Diagram 5

7)Install the Wall Thimble in the center of the 10" square and attach with wood screws.

8)Slide the decorative wall thimble up to the wall surface being careful not to scratch the paintand attach withscrews provided.Apply decorative brass or chrome trim if desired. See diagram 7.

Diagram 9

3)To install the Round Support Box/Wall Thimble in a fl at ceiling, cut a 10 inch square hole in the ceiling centred on the hole drilled in Step 2. Frame the hole as shown in diagram 10.

Diagram 7

Diagram 10

Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove

19

Image 19
Contents Ultimate U39 Regency Table of Contents Copy of Safety Label for U39 Gas Stove Safety LabelMA Code CO Detector RequirementsBefore YOU Start InstallationSpecifications Important Message Save These InstructionsGeneral Safety Information Installation ChecklistClearances to Combustibles Locating Your Ultimate GAS Stove Louver InstallationVenting Introduction Manufactured Mobile Home Additional RequirementsExterior Vent Terminal Description 6-5/8 Rigid Pipe Cross Reference Chart6-5/8 Rigid Pipe Cross Reference Chart Alternate Rigid Pipe Venting SystemsMination Caps Vent Restrictor Position Installation Precautions Rigid Pipe Venting ArrangementsSafety Precautions for Installer Horizontal Terminations for All Venting SystemsVertical Venting with Two 2 90o Elbows Horizontal Venting with Two 2 90o ElbowsDV Stove Horizontal Vent KIT Installation Capcanbemounted on DURA-VENT Venting Components Planning Your Dura-Vent InstallationMinimum components for a Dura-Vent Horizontal Installation DURA-VENT Termination KITSnorkel Terminations DURA-VENT Horizontal TerminationsDURA-VENT Vertical Terminations Below Grade InstallationCathedral Ceilings Offset ChartConverting a Factory Built Metal Chimney Approved for US Installations OnlySupport Extensions Round Rdse or Square Sqse GeneralConverting a Masonry Chimney System Data GAS ConnectionHigh Elevation System Data U39 with 40,000 BTULPG Conversion Kit Contains Qty Conversion KIT# 731-969 from NG to LPOnly Required for the U38 Green ground wire Propane Conversion Kit 730-922 Contains GAS Pipe Pressure TestingConversion to Lower BTU Rating Natural Gas Conversion Kit 730-920 ContainsU39 with 30,000 Btu/h Aeration AdjustmentValve Description U39 with 38,000 Btu/hLOG SET Installation B02-56 E02-45 G02 A02-65 Wiring Diagram 14 GA 16 GA 18 GA 20 GA 22 GA Final CheckShutdown Instructions Lighting ProcedureOperating Instructions Operating InstructionsAutomatic Convection FAN Operation Normal Operating Sounds GAS AppliancesCopy Of Lighting Plate Instructions GOLD-PLATED Doors MaintenanceMaintenance Instructions General Vent MaintenanceDoor Gasket LOG ReplacementLatch Adjustment Glass ReplacementTo Remove U39 Fan FAN MaintenanceDC Sparker Battery Replacement Alternate Fan AccessRemoving Valve Main Assembly Parts ListDescription Burner & LOG Assembly Door Assemblies Conditions WarrantyInstaller Please complete the following information

U39-LP1, U39-NG1 specifications

The Regency U39-LP1 and U39-NG1 are innovative heating appliances designed for modern homes, emphasizing both efficiency and style. These units encapsulate the essence of contemporary design while ensuring high-performance heating solutions. The U39 series stands out for its user-friendly features and advanced technologies that cater to the demands of varied environments.

One of the main features of the U39-LP1 is its propane-fueled operation, allowing it to generate an impressive amount of heat while remaining energy-efficient. The unit is designed with a remarkable heating capacity, making it ideal for larger spaces or for those chilly evenings where comfort is paramount. In contrast, the U39-NG1 operates on natural gas, appealing to homeowners looking for a more sustainable option. Both models allow for quick and effective heating, ensuring a cozy atmosphere within moments.

The technology embedded in both models reflects a commitment to top-tier performance. The advanced electronic ignition system provides reliability, ensuring seamless operation. The units also incorporate a built-in thermostat, which allows for precise control over the temperature, enhancing comfort while conserving energy. Furthermore, the U39 series features a sleek ceramic glass front that not only adds an aesthetic element but also enhances efficiency by radiating heat effectively into the room.

Another hallmark of the Regency U39 series is its design versatility. Both models are available in various finishes, enabling them to blend seamlessly into different décor styles, whether traditional, modern, or minimalist. The compact dimensions of these units ensure they fit effortlessly into a variety of spaces, from living rooms to basements.

Safety is also a significant focus with the U39-LP1 and U39-NG1. The units come equipped with a variety of safety features, including automatic shut-off and heat-resistant materials, ensuring peace of mind for users.

In summary, the Regency U39-LP1 and U39-NG1 models exemplify modern heating solutions characterized by efficiency, advanced technology, and stylish design. With their user-centric features and commitment to safety, these units are perfect additions for anyone seeking warmth and comfort in their homes. Whether powered by propane or natural gas, the U39 series continues to redefine the standard for home heating.