Regency U39-LP1, U39-NG1 installation manual Green ground wire

Page 26

INSTALLATION

6) Secure with screw.

11) Attach the Piezo Ignition Wire to the

 

back of the DC Sparker box.

15)Attach the green ground wire.

7)Reversing step 2 and secure the control panel back onto the stove pedestal with the screws.

12)The ground wire and DC Sparker ignition go through the hole on the heat shield.

green ground wire

16)Install the supplied battery into the DC Sparker Box by opening the battery compartment.

NOTE: The battery in the DC Sparker Box will need to be replaced annually.

Battery

Compartment

8)Attach one end of the green ground wire to the grounding stud on the inside of the pedestal.

9)The Ground Wire, DC Sparker Ignition Wire and Piezo Spark Wire all go through the hole located on the pedestal back cover.

10)Put on the plastic split bushing.

13)Apply the plastic bushing to the heat shield hole.

14)Connect the DC Sparker Ignition Wire to the DC Sparker.

17)Place the heat shield over the DC Sparker.

18)We recommend mounting the DC Sparker box onto the pedestal back cover.

19)Check for gas leaks.

20)Check inlet and outlet pressures.

21)Check operation of fl ame control.

22)Check for proper fl ame appearance and glow on logs.

26

Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove

Image 26
Contents Ultimate U39 Regency Table of Contents Safety Label Copy of Safety Label for U39 Gas StoveRequirements MA Code CO DetectorImportant Message Save These Instructions InstallationSpecifications Before YOU StartClearances to Combustibles Installation ChecklistGeneral Safety Information Manufactured Mobile Home Additional Requirements Louver InstallationVenting Introduction Locating Your Ultimate GAS StoveExterior Vent Terminal 6-5/8 Rigid Pipe Cross Reference Chart Description6-5/8 Rigid Pipe Cross Reference Chart Mination Caps Rigid Pipe Venting SystemsAlternate Horizontal Terminations for All Venting Systems Installation Precautions Rigid Pipe Venting ArrangementsSafety Precautions for Installer Vent Restrictor PositionHorizontal Venting with Two 2 90o Elbows Vertical Venting with Two 2 90o ElbowsDV Stove Horizontal Vent KIT Installation Capcanbemounted on DURA-VENT Termination KIT Planning Your Dura-Vent InstallationMinimum components for a Dura-Vent Horizontal Installation DURA-VENT Venting ComponentsDURA-VENT Horizontal Terminations Snorkel TerminationsBelow Grade Installation DURA-VENT Vertical TerminationsOffset Chart Cathedral CeilingsGeneral Approved for US Installations OnlySupport Extensions Round Rdse or Square Sqse Converting a Factory Built Metal ChimneyConverting a Masonry Chimney System Data U39 with 40,000 BTU GAS ConnectionHigh Elevation System DataConversion KIT# 731-969 from NG to LP LPG Conversion Kit Contains QtyOnly Required for the U38 Green ground wire Natural Gas Conversion Kit 730-920 Contains GAS Pipe Pressure TestingConversion to Lower BTU Rating Propane Conversion Kit 730-922 ContainsU39 with 38,000 Btu/h Aeration AdjustmentValve Description U39 with 30,000 Btu/hLOG SET Installation B02-56 E02-45 G02 A02-65 Wiring Diagram Final Check 14 GA 16 GA 18 GA 20 GA 22 GAOperating Instructions Lighting ProcedureOperating Instructions Shutdown InstructionsCopy Of Lighting Plate Instructions Normal Operating Sounds GAS AppliancesAutomatic Convection FAN Operation General Vent Maintenance MaintenanceMaintenance Instructions GOLD-PLATED DoorsGlass Replacement LOG ReplacementLatch Adjustment Door GasketAlternate Fan Access FAN MaintenanceDC Sparker Battery Replacement To Remove U39 FanRemoving Valve Description Parts ListMain Assembly Burner & LOG Assembly Door Assemblies Warranty ConditionsInstaller Please complete the following information

U39-LP1, U39-NG1 specifications

The Regency U39-LP1 and U39-NG1 are innovative heating appliances designed for modern homes, emphasizing both efficiency and style. These units encapsulate the essence of contemporary design while ensuring high-performance heating solutions. The U39 series stands out for its user-friendly features and advanced technologies that cater to the demands of varied environments.

One of the main features of the U39-LP1 is its propane-fueled operation, allowing it to generate an impressive amount of heat while remaining energy-efficient. The unit is designed with a remarkable heating capacity, making it ideal for larger spaces or for those chilly evenings where comfort is paramount. In contrast, the U39-NG1 operates on natural gas, appealing to homeowners looking for a more sustainable option. Both models allow for quick and effective heating, ensuring a cozy atmosphere within moments.

The technology embedded in both models reflects a commitment to top-tier performance. The advanced electronic ignition system provides reliability, ensuring seamless operation. The units also incorporate a built-in thermostat, which allows for precise control over the temperature, enhancing comfort while conserving energy. Furthermore, the U39 series features a sleek ceramic glass front that not only adds an aesthetic element but also enhances efficiency by radiating heat effectively into the room.

Another hallmark of the Regency U39 series is its design versatility. Both models are available in various finishes, enabling them to blend seamlessly into different décor styles, whether traditional, modern, or minimalist. The compact dimensions of these units ensure they fit effortlessly into a variety of spaces, from living rooms to basements.

Safety is also a significant focus with the U39-LP1 and U39-NG1. The units come equipped with a variety of safety features, including automatic shut-off and heat-resistant materials, ensuring peace of mind for users.

In summary, the Regency U39-LP1 and U39-NG1 models exemplify modern heating solutions characterized by efficiency, advanced technology, and stylish design. With their user-centric features and commitment to safety, these units are perfect additions for anyone seeking warmth and comfort in their homes. Whether powered by propane or natural gas, the U39 series continues to redefine the standard for home heating.