INSTALLATION

OPTIONAL WALL

OPTIONAL REMOTE

THERMOSTAT

CONTROL

FINAL CHECK

Before leaving this unit with the customer, the installer must ensure that the appliance is fi ring

A wall thermostat may be installed if desired. Connect the wires as per the wiring diagrams. Note that the wires are connected to the "TH" on the gas valve. Use table below to determine the maximum wire length:

Note: Preferable if the thermostat is installed on an interior wall.

Regency® offers an optional programmable thermostat but any 250-750 millivolt rated non- anticipator type thermostat that is CSA, ULC or UL approved may be used.

CAUTION

Do not connect the millivolt

wall thermostat wires

to the 120V wires.

Thermostat Wire Table

Recommended Maximum Lead Length

(Two-Wire) When Using Wall

Thermostat (CP-2 System)

 

Wire Size

 

Max. Length

 

 

 

14 GA.

 

50

Ft.

 

 

16 GA.

 

32

Ft.

 

 

 

18 GA.

 

20

Ft.

 

 

20 GA.

 

12

Ft.

 

 

22 GA.

 

9

Ft.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Use the Regency® Remote Control Kit approved for this unit. Use of other systems may void your warranty.

The remote control kit comes with a hand held transmitter, a receiver and a wall mounting plate.

1)Choose a convenient location on the wall to install the receiver and the receptacle box (protection from extreme heat is very important). Run wires from the fi replace to that location, use Thermostat Wire Table.

2)Connect the wires as per the wiring diagram above.

CAUTION

Do not connect the millivolt

remote control wires to

the 120V wires.

3)Install 3AAAalkaline batteries in transmitter and 4 AA alkaline batteries in the receiver. Install the receiver and its cover in the wall. Switch the remote receiver to "remote" mode. The remote control is now ready for operation.

correctly. This includes:

1)Clocking the appliance to ensure the correct fi ring rate (rate noted on label) at 15 minutes.

2)Ifrequired,adjustingtheprimaryairtoensure that the fl ame does not carbon. First allow the unit to burn for 15 min. to stabilize.

3)Check for proper draft.

CAUTION

Any alteration to the product that causes sooting or carboning that results in damage to the exterior facia is not the responsibility of the manufacturer.

Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove

33

Image 33
Contents Ultimate U39 Regency Table of Contents Copy of Safety Label for U39 Gas Stove Safety LabelMA Code CO Detector RequirementsSpecifications InstallationImportant Message Save These Instructions Before YOU StartInstallation Checklist General Safety InformationClearances to Combustibles Venting Introduction Louver InstallationManufactured Mobile Home Additional Requirements Locating Your Ultimate GAS StoveExterior Vent Terminal Description 6-5/8 Rigid Pipe Cross Reference Chart6-5/8 Rigid Pipe Cross Reference Chart Rigid Pipe Venting Systems AlternateMination Caps Safety Precautions for Installer Installation Precautions Rigid Pipe Venting ArrangementsHorizontal Terminations for All Venting Systems Vent Restrictor PositionVertical Venting with Two 2 90o Elbows Horizontal Venting with Two 2 90o ElbowsDV Stove Horizontal Vent KIT Installation Capcanbemounted on Minimum components for a Dura-Vent Horizontal Installation Planning Your Dura-Vent InstallationDURA-VENT Termination KIT DURA-VENT Venting ComponentsSnorkel Terminations DURA-VENT Horizontal TerminationsDURA-VENT Vertical Terminations Below Grade InstallationCathedral Ceilings Offset ChartSupport Extensions Round Rdse or Square Sqse Approved for US Installations OnlyGeneral Converting a Factory Built Metal ChimneyConverting a Masonry Chimney High Elevation GAS ConnectionSystem Data U39 with 40,000 BTU System DataLPG Conversion Kit Contains Qty Conversion KIT# 731-969 from NG to LPOnly Required for the U38 Green ground wire Conversion to Lower BTU Rating GAS Pipe Pressure TestingNatural Gas Conversion Kit 730-920 Contains Propane Conversion Kit 730-922 ContainsValve Description Aeration AdjustmentU39 with 38,000 Btu/h U39 with 30,000 Btu/hLOG SET Installation B02-56 E02-45 G02 A02-65 Wiring Diagram 14 GA 16 GA 18 GA 20 GA 22 GA Final CheckOperating Instructions Lighting ProcedureOperating Instructions Shutdown InstructionsNormal Operating Sounds GAS Appliances Automatic Convection FAN OperationCopy Of Lighting Plate Instructions Maintenance Instructions MaintenanceGeneral Vent Maintenance GOLD-PLATED DoorsLatch Adjustment LOG ReplacementGlass Replacement Door GasketDC Sparker Battery Replacement FAN MaintenanceAlternate Fan Access To Remove U39 FanRemoving Valve Parts List Main AssemblyDescription Burner & LOG Assembly Door Assemblies Conditions WarrantyInstaller Please complete the following information

U39-LP1, U39-NG1 specifications

The Regency U39-LP1 and U39-NG1 are innovative heating appliances designed for modern homes, emphasizing both efficiency and style. These units encapsulate the essence of contemporary design while ensuring high-performance heating solutions. The U39 series stands out for its user-friendly features and advanced technologies that cater to the demands of varied environments.

One of the main features of the U39-LP1 is its propane-fueled operation, allowing it to generate an impressive amount of heat while remaining energy-efficient. The unit is designed with a remarkable heating capacity, making it ideal for larger spaces or for those chilly evenings where comfort is paramount. In contrast, the U39-NG1 operates on natural gas, appealing to homeowners looking for a more sustainable option. Both models allow for quick and effective heating, ensuring a cozy atmosphere within moments.

The technology embedded in both models reflects a commitment to top-tier performance. The advanced electronic ignition system provides reliability, ensuring seamless operation. The units also incorporate a built-in thermostat, which allows for precise control over the temperature, enhancing comfort while conserving energy. Furthermore, the U39 series features a sleek ceramic glass front that not only adds an aesthetic element but also enhances efficiency by radiating heat effectively into the room.

Another hallmark of the Regency U39 series is its design versatility. Both models are available in various finishes, enabling them to blend seamlessly into different décor styles, whether traditional, modern, or minimalist. The compact dimensions of these units ensure they fit effortlessly into a variety of spaces, from living rooms to basements.

Safety is also a significant focus with the U39-LP1 and U39-NG1. The units come equipped with a variety of safety features, including automatic shut-off and heat-resistant materials, ensuring peace of mind for users.

In summary, the Regency U39-LP1 and U39-NG1 models exemplify modern heating solutions characterized by efficiency, advanced technology, and stylish design. With their user-centric features and commitment to safety, these units are perfect additions for anyone seeking warmth and comfort in their homes. Whether powered by propane or natural gas, the U39 series continues to redefine the standard for home heating.