Regency U39-LP1, U39-NG1 Venting Introduction, Manufactured Mobile Home Additional Requirements

Page 8

INSTALLATION

A)Cross Corner

B)Room Divider

C)Island

D)Flat on Wall

E)Flat on Wall Corner

F)Flush with Wall/ Alcove

For Vent Termination requirements, see "Exterior Vent termination Locations" section.

VENTING

INTRODUCTION

The DV Stove Horizontal Vent Kit and the Simpson Dura-Vent Direct Vent System Model DV-GS venting systems, in combination with the ULTIMATE Direct Vent Freestanding Gas Stove, U39-NG1, and U39-LP1, have been tested and listed as direct vent heater systems by Warnock Hersey. If converting a Class-A Metal Chimney or Masonry Chimney to a Direct Vent system, see instructions in "Converting a Class-A Metal Chimney or Masonry Chimey to a Direct Vent System" section.

These units use the "balanced fl ue" technology Co-Axial system. The inner liner vents products of combustion to the outside while the outer pipe draws outside combustion air into the combustion chamber thereby eliminating the need to use heated room air for combustion and

Minimum ceiling

height is 36"/914mm

from top of unit.

MANUFACTURED

MOBILE HOME

ADDITIONAL

REQUIREMENTS

1)Ensure that structural members are not cut or weakened during installation.

LOUVER

INSTALLATION

1)Attach the top & bottom louvers to the side stove panel using 2 screws per side.

losing warm room air up the chimney.

Note: These flue pipes must not be connected to any other appliance.

The gas appliance and vent system must be vented directly to the outside of the building, and never be attached to a chimney serving a separate solid fuel or gas burning appliance. Each direct vent gas appliance must use it's own separate vent system. Common vent systems are prohibited.

IMPORTANT

Read all instructions carefully before starting the installation. Failure to follow these instructions may create a fi re or other safety hazard, and will void the warranty. Be sure to check the venting and clearance to combustible requirements. Consult your local building codes before beginning installation.

Thelocationofthetermination capmust conform totherequirementsinthe "ExteriorVentTerminal Locations" section.

2)Ensurepropergroundingusingthe#8ground lug provided.

3)Appliance must be anchored to the fl oor with the supplied anchoring methods.

LOCATING YOUR

ULTIMATE GAS STOVE

When selecting a location for your stove, ensure that the clearances listed above are met as well as ensuring that there is adequate accessibility for servicing and proper operation.

COMBUSTION AND VENTILATION AIR

The combustion air from this appliance is drawn from outside the building through the outer fl ue.

Extra provision for combustion air inside the room is not required.

8

Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove

Image 8
Contents Ultimate U39 Regency Table of Contents Safety Label Copy of Safety Label for U39 Gas StoveRequirements MA Code CO DetectorInstallation SpecificationsImportant Message Save These Instructions Before YOU StartClearances to Combustibles Installation ChecklistGeneral Safety Information Louver Installation Venting IntroductionManufactured Mobile Home Additional Requirements Locating Your Ultimate GAS StoveExterior Vent Terminal 6-5/8 Rigid Pipe Cross Reference Chart Description6-5/8 Rigid Pipe Cross Reference Chart Mination Caps Rigid Pipe Venting SystemsAlternate Installation Precautions Rigid Pipe Venting Arrangements Safety Precautions for InstallerHorizontal Terminations for All Venting Systems Vent Restrictor PositionHorizontal Venting with Two 2 90o Elbows Vertical Venting with Two 2 90o ElbowsDV Stove Horizontal Vent KIT Installation Capcanbemounted on Planning Your Dura-Vent Installation Minimum components for a Dura-Vent Horizontal InstallationDURA-VENT Termination KIT DURA-VENT Venting ComponentsDURA-VENT Horizontal Terminations Snorkel TerminationsBelow Grade Installation DURA-VENT Vertical TerminationsOffset Chart Cathedral CeilingsApproved for US Installations Only Support Extensions Round Rdse or Square SqseGeneral Converting a Factory Built Metal ChimneyConverting a Masonry Chimney GAS Connection High ElevationSystem Data U39 with 40,000 BTU System DataConversion KIT# 731-969 from NG to LP LPG Conversion Kit Contains QtyOnly Required for the U38 Green ground wire GAS Pipe Pressure Testing Conversion to Lower BTU RatingNatural Gas Conversion Kit 730-920 Contains Propane Conversion Kit 730-922 ContainsAeration Adjustment Valve DescriptionU39 with 38,000 Btu/h U39 with 30,000 Btu/hLOG SET Installation B02-56 E02-45 G02 A02-65 Wiring Diagram Final Check 14 GA 16 GA 18 GA 20 GA 22 GALighting Procedure Operating InstructionsOperating Instructions Shutdown InstructionsCopy Of Lighting Plate Instructions Normal Operating Sounds GAS AppliancesAutomatic Convection FAN Operation Maintenance Maintenance InstructionsGeneral Vent Maintenance GOLD-PLATED DoorsLOG Replacement Latch AdjustmentGlass Replacement Door GasketFAN Maintenance DC Sparker Battery ReplacementAlternate Fan Access To Remove U39 FanRemoving Valve Description Parts ListMain Assembly Burner & LOG Assembly Door Assemblies Warranty ConditionsInstaller Please complete the following information

U39-LP1, U39-NG1 specifications

The Regency U39-LP1 and U39-NG1 are innovative heating appliances designed for modern homes, emphasizing both efficiency and style. These units encapsulate the essence of contemporary design while ensuring high-performance heating solutions. The U39 series stands out for its user-friendly features and advanced technologies that cater to the demands of varied environments.

One of the main features of the U39-LP1 is its propane-fueled operation, allowing it to generate an impressive amount of heat while remaining energy-efficient. The unit is designed with a remarkable heating capacity, making it ideal for larger spaces or for those chilly evenings where comfort is paramount. In contrast, the U39-NG1 operates on natural gas, appealing to homeowners looking for a more sustainable option. Both models allow for quick and effective heating, ensuring a cozy atmosphere within moments.

The technology embedded in both models reflects a commitment to top-tier performance. The advanced electronic ignition system provides reliability, ensuring seamless operation. The units also incorporate a built-in thermostat, which allows for precise control over the temperature, enhancing comfort while conserving energy. Furthermore, the U39 series features a sleek ceramic glass front that not only adds an aesthetic element but also enhances efficiency by radiating heat effectively into the room.

Another hallmark of the Regency U39 series is its design versatility. Both models are available in various finishes, enabling them to blend seamlessly into different décor styles, whether traditional, modern, or minimalist. The compact dimensions of these units ensure they fit effortlessly into a variety of spaces, from living rooms to basements.

Safety is also a significant focus with the U39-LP1 and U39-NG1. The units come equipped with a variety of safety features, including automatic shut-off and heat-resistant materials, ensuring peace of mind for users.

In summary, the Regency U39-LP1 and U39-NG1 models exemplify modern heating solutions characterized by efficiency, advanced technology, and stylish design. With their user-centric features and commitment to safety, these units are perfect additions for anyone seeking warmth and comfort in their homes. Whether powered by propane or natural gas, the U39 series continues to redefine the standard for home heating.