Regency U39-NG1, U39-LP1 installation manual Burner & LOG Assembly

Page 41

PARTS LIST

BURNER & LOG ASSEMBLY

Part # Description

51)910-241 Burner ON/OFF Switch (3-way)

52)910-190 Piezo Ignitor & Nut

53)904-586 Knob for Fan Speed Control

54)910-373 Knob - Pilot Valve Extension

55)910-372 Flame Adjusting Knob

56) 908-646

Control Panel Decal

57)650-220 Control Panel Plate

58)910-330 Fan Speed Control (120 V)

730-574/P Valve Assembly - Natural Gas

730-576/P Valve Assembly - Propane

60) 910-478

Valve S.I.T. - NG/LP

66)910-038 Pilot Assy - S.I.T. - 3 Flame NG

910-039 Pilot Assy - S.I.T. - 3 Flame LP

904-240 #37 Orifi ce - N.G. at 30,000 Btu/h

904-688 #32 Orifi ce - N.G. at 38,000 Btu/h

904-390 #52 Orifi ce - Propane at 30,000 Btu/h 904-641 #50 Orifi ce - Propane at 38,000 Btu/h 936-170 Orifi ce Gasket

67) *

Pilot Holder

68)W840470 Pilot Assembly Gasket

71)730-528 Rear Log Bracket

75) 730-935

Log Set

77)630-008 Gasket - Burner Tray/Firebox

78)730-550 Burner Assembly (NG/LP)

80)260-565 Air Shutter Gear Assembly - Female

81)

904-565

Hex Key 3/16" AF

82)

630-009

Gasket-Burner Tray/Air Passage

84)

*

Air Shutter Gear Assembly - Male

*Not available as a replacement part.

Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove

41

Image 41
Contents Ultimate U39 Regency Table of Contents Copy of Safety Label for U39 Gas Stove Safety LabelMA Code CO Detector RequirementsSpecifications InstallationImportant Message Save These Instructions Before YOU StartClearances to Combustibles Installation ChecklistGeneral Safety Information Venting Introduction Louver InstallationManufactured Mobile Home Additional Requirements Locating Your Ultimate GAS StoveExterior Vent Terminal Description 6-5/8 Rigid Pipe Cross Reference Chart6-5/8 Rigid Pipe Cross Reference Chart Mination Caps Rigid Pipe Venting SystemsAlternate Safety Precautions for Installer Installation Precautions Rigid Pipe Venting ArrangementsHorizontal Terminations for All Venting Systems Vent Restrictor PositionVertical Venting with Two 2 90o Elbows Horizontal Venting with Two 2 90o ElbowsDV Stove Horizontal Vent KIT Installation Capcanbemounted on Minimum components for a Dura-Vent Horizontal Installation Planning Your Dura-Vent InstallationDURA-VENT Termination KIT DURA-VENT Venting ComponentsSnorkel Terminations DURA-VENT Horizontal TerminationsDURA-VENT Vertical Terminations Below Grade InstallationCathedral Ceilings Offset ChartSupport Extensions Round Rdse or Square Sqse Approved for US Installations OnlyGeneral Converting a Factory Built Metal ChimneyConverting a Masonry Chimney High Elevation GAS ConnectionSystem Data U39 with 40,000 BTU System DataLPG Conversion Kit Contains Qty Conversion KIT# 731-969 from NG to LPOnly Required for the U38 Green ground wire Conversion to Lower BTU Rating GAS Pipe Pressure TestingNatural Gas Conversion Kit 730-920 Contains Propane Conversion Kit 730-922 ContainsValve Description Aeration AdjustmentU39 with 38,000 Btu/h U39 with 30,000 Btu/hLOG SET Installation B02-56 E02-45 G02 A02-65 Wiring Diagram 14 GA 16 GA 18 GA 20 GA 22 GA Final CheckOperating Instructions Lighting ProcedureOperating Instructions Shutdown InstructionsCopy Of Lighting Plate Instructions Normal Operating Sounds GAS AppliancesAutomatic Convection FAN Operation Maintenance Instructions MaintenanceGeneral Vent Maintenance GOLD-PLATED DoorsLatch Adjustment LOG ReplacementGlass Replacement Door GasketDC Sparker Battery Replacement FAN MaintenanceAlternate Fan Access To Remove U39 FanRemoving Valve Description Parts ListMain Assembly Burner & LOG Assembly Door Assemblies Conditions WarrantyInstaller Please complete the following information

U39-LP1, U39-NG1 specifications

The Regency U39-LP1 and U39-NG1 are innovative heating appliances designed for modern homes, emphasizing both efficiency and style. These units encapsulate the essence of contemporary design while ensuring high-performance heating solutions. The U39 series stands out for its user-friendly features and advanced technologies that cater to the demands of varied environments.

One of the main features of the U39-LP1 is its propane-fueled operation, allowing it to generate an impressive amount of heat while remaining energy-efficient. The unit is designed with a remarkable heating capacity, making it ideal for larger spaces or for those chilly evenings where comfort is paramount. In contrast, the U39-NG1 operates on natural gas, appealing to homeowners looking for a more sustainable option. Both models allow for quick and effective heating, ensuring a cozy atmosphere within moments.

The technology embedded in both models reflects a commitment to top-tier performance. The advanced electronic ignition system provides reliability, ensuring seamless operation. The units also incorporate a built-in thermostat, which allows for precise control over the temperature, enhancing comfort while conserving energy. Furthermore, the U39 series features a sleek ceramic glass front that not only adds an aesthetic element but also enhances efficiency by radiating heat effectively into the room.

Another hallmark of the Regency U39 series is its design versatility. Both models are available in various finishes, enabling them to blend seamlessly into different décor styles, whether traditional, modern, or minimalist. The compact dimensions of these units ensure they fit effortlessly into a variety of spaces, from living rooms to basements.

Safety is also a significant focus with the U39-LP1 and U39-NG1. The units come equipped with a variety of safety features, including automatic shut-off and heat-resistant materials, ensuring peace of mind for users.

In summary, the Regency U39-LP1 and U39-NG1 models exemplify modern heating solutions characterized by efficiency, advanced technology, and stylish design. With their user-centric features and commitment to safety, these units are perfect additions for anyone seeking warmth and comfort in their homes. Whether powered by propane or natural gas, the U39 series continues to redefine the standard for home heating.