Regency U39-NG1, U39-LP1 installation manual G02 A02-65

Page 31

INSTALLATION

11)Place the notch in Center Log F)02-47 over

Log E)02-45 and across the cutout on Log A)02- 65.

F)02-47

A)02-65

E)02-45

G)02-48

E)02-45

Side

View

Bracket

Notch Cutout

12)Position notch in Front Right Log G)02-48 on Log F)02-47 and push the bottom right edge against the bracket on the burner tray.

G)02

-48

 

A)02-65

 

47

F)02

-

E)02-45

 

Notch

The bottom right edge of Log G)02-48 must sit snugly against the bracket

13)Test fire to ensure proper light off (make sure flame fl ows smoothly from one end of burner to the other. If there is any flame hesitation, check that area for any blockage of the burner port.

 

 

 

 

 

 

G)02

A)02-65

 

 

 

 

 

 

 

B)02-56

 

46

 

 

 

-

 

 

 

47

 

48

 

D)02

-

 

-

 

 

 

 

 

 

 

 

 

F)02

 

 

 

 

 

 

 

 

 

 

C)02-44

 

 

E)02-45

 

 

 

 

 

 

Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove

31

Image 31
Contents Ultimate U39 Regency Table of Contents Copy of Safety Label for U39 Gas Stove Safety LabelMA Code CO Detector RequirementsBefore YOU Start InstallationSpecifications Important Message Save These InstructionsGeneral Safety Information Installation ChecklistClearances to Combustibles Locating Your Ultimate GAS Stove Louver InstallationVenting Introduction Manufactured Mobile Home Additional RequirementsExterior Vent Terminal Description 6-5/8 Rigid Pipe Cross Reference Chart6-5/8 Rigid Pipe Cross Reference Chart Alternate Rigid Pipe Venting SystemsMination Caps Vent Restrictor Position Installation Precautions Rigid Pipe Venting ArrangementsSafety Precautions for Installer Horizontal Terminations for All Venting SystemsVertical Venting with Two 2 90o Elbows Horizontal Venting with Two 2 90o ElbowsDV Stove Horizontal Vent KIT Installation Capcanbemounted on DURA-VENT Venting Components Planning Your Dura-Vent InstallationMinimum components for a Dura-Vent Horizontal Installation DURA-VENT Termination KITSnorkel Terminations DURA-VENT Horizontal TerminationsDURA-VENT Vertical Terminations Below Grade InstallationCathedral Ceilings Offset ChartConverting a Factory Built Metal Chimney Approved for US Installations OnlySupport Extensions Round Rdse or Square Sqse GeneralConverting a Masonry Chimney System Data GAS ConnectionHigh Elevation System Data U39 with 40,000 BTULPG Conversion Kit Contains Qty Conversion KIT# 731-969 from NG to LPOnly Required for the U38 Green ground wire Propane Conversion Kit 730-922 Contains GAS Pipe Pressure TestingConversion to Lower BTU Rating Natural Gas Conversion Kit 730-920 ContainsU39 with 30,000 Btu/h Aeration AdjustmentValve Description U39 with 38,000 Btu/hLOG SET Installation B02-56 E02-45 G02 A02-65 Wiring Diagram 14 GA 16 GA 18 GA 20 GA 22 GA Final CheckShutdown Instructions Lighting ProcedureOperating Instructions Operating InstructionsAutomatic Convection FAN Operation Normal Operating Sounds GAS AppliancesCopy Of Lighting Plate Instructions GOLD-PLATED Doors MaintenanceMaintenance Instructions General Vent MaintenanceDoor Gasket LOG ReplacementLatch Adjustment Glass ReplacementTo Remove U39 Fan FAN MaintenanceDC Sparker Battery Replacement Alternate Fan AccessRemoving Valve Main Assembly Parts ListDescription Burner & LOG Assembly Door Assemblies Conditions WarrantyInstaller Please complete the following information

U39-LP1, U39-NG1 specifications

The Regency U39-LP1 and U39-NG1 are innovative heating appliances designed for modern homes, emphasizing both efficiency and style. These units encapsulate the essence of contemporary design while ensuring high-performance heating solutions. The U39 series stands out for its user-friendly features and advanced technologies that cater to the demands of varied environments.

One of the main features of the U39-LP1 is its propane-fueled operation, allowing it to generate an impressive amount of heat while remaining energy-efficient. The unit is designed with a remarkable heating capacity, making it ideal for larger spaces or for those chilly evenings where comfort is paramount. In contrast, the U39-NG1 operates on natural gas, appealing to homeowners looking for a more sustainable option. Both models allow for quick and effective heating, ensuring a cozy atmosphere within moments.

The technology embedded in both models reflects a commitment to top-tier performance. The advanced electronic ignition system provides reliability, ensuring seamless operation. The units also incorporate a built-in thermostat, which allows for precise control over the temperature, enhancing comfort while conserving energy. Furthermore, the U39 series features a sleek ceramic glass front that not only adds an aesthetic element but also enhances efficiency by radiating heat effectively into the room.

Another hallmark of the Regency U39 series is its design versatility. Both models are available in various finishes, enabling them to blend seamlessly into different décor styles, whether traditional, modern, or minimalist. The compact dimensions of these units ensure they fit effortlessly into a variety of spaces, from living rooms to basements.

Safety is also a significant focus with the U39-LP1 and U39-NG1. The units come equipped with a variety of safety features, including automatic shut-off and heat-resistant materials, ensuring peace of mind for users.

In summary, the Regency U39-LP1 and U39-NG1 models exemplify modern heating solutions characterized by efficiency, advanced technology, and stylish design. With their user-centric features and commitment to safety, these units are perfect additions for anyone seeking warmth and comfort in their homes. Whether powered by propane or natural gas, the U39 series continues to redefine the standard for home heating.