Regency U39-LP1, U39-NG1 installation manual Copy of Safety Label for U39 Gas Stove

Page 4

SAFETY LABEL

This is a copy of the label that accompanies each ULTIMATE Direct Vent Freestanding Gas Stove. We have printed a copy of the contents here for your review. The safety

label is located on the inside of the drop down pedestal door.

NOTE: Regency® units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.

Copy of Safety Label for U39 Gas Stove

For the State of Massachusetts, installation and repair must be done by a plumber or gasfi tter licensed in the Commonwealth of Massachusetts.

For the State of Massachusetts, fl exible connectors shall not exceed 36 inches in length.

For the State of Massachusetts, the appliances individual manual shut-off must be a t-handle type valve.

The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm with battery back up in the same room where the gas appliance is installed.

4

Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove

Image 4
Contents Ultimate U39 Regency Table of Contents Safety Label Copy of Safety Label for U39 Gas StoveRequirements MA Code CO DetectorInstallation SpecificationsImportant Message Save These Instructions Before YOU StartGeneral Safety Information Installation ChecklistClearances to Combustibles Louver Installation Venting IntroductionManufactured Mobile Home Additional Requirements Locating Your Ultimate GAS StoveExterior Vent Terminal 6-5/8 Rigid Pipe Cross Reference Chart Description6-5/8 Rigid Pipe Cross Reference Chart Alternate Rigid Pipe Venting SystemsMination Caps Installation Precautions Rigid Pipe Venting Arrangements Safety Precautions for InstallerHorizontal Terminations for All Venting Systems Vent Restrictor PositionHorizontal Venting with Two 2 90o Elbows Vertical Venting with Two 2 90o ElbowsDV Stove Horizontal Vent KIT Installation Capcanbemounted on Planning Your Dura-Vent Installation Minimum components for a Dura-Vent Horizontal InstallationDURA-VENT Termination KIT DURA-VENT Venting ComponentsDURA-VENT Horizontal Terminations Snorkel TerminationsBelow Grade Installation DURA-VENT Vertical TerminationsOffset Chart Cathedral CeilingsApproved for US Installations Only Support Extensions Round Rdse or Square SqseGeneral Converting a Factory Built Metal ChimneyConverting a Masonry Chimney GAS Connection High ElevationSystem Data U39 with 40,000 BTU System DataConversion KIT# 731-969 from NG to LP LPG Conversion Kit Contains QtyOnly Required for the U38 Green ground wire GAS Pipe Pressure Testing Conversion to Lower BTU RatingNatural Gas Conversion Kit 730-920 Contains Propane Conversion Kit 730-922 ContainsAeration Adjustment Valve DescriptionU39 with 38,000 Btu/h U39 with 30,000 Btu/hLOG SET Installation B02-56 E02-45 G02 A02-65 Wiring Diagram Final Check 14 GA 16 GA 18 GA 20 GA 22 GALighting Procedure Operating InstructionsOperating Instructions Shutdown InstructionsAutomatic Convection FAN Operation Normal Operating Sounds GAS AppliancesCopy Of Lighting Plate Instructions Maintenance Maintenance InstructionsGeneral Vent Maintenance GOLD-PLATED DoorsLOG Replacement Latch AdjustmentGlass Replacement Door GasketFAN Maintenance DC Sparker Battery ReplacementAlternate Fan Access To Remove U39 FanRemoving Valve Main Assembly Parts ListDescription Burner & LOG Assembly Door Assemblies Warranty ConditionsInstaller Please complete the following information

U39-LP1, U39-NG1 specifications

The Regency U39-LP1 and U39-NG1 are innovative heating appliances designed for modern homes, emphasizing both efficiency and style. These units encapsulate the essence of contemporary design while ensuring high-performance heating solutions. The U39 series stands out for its user-friendly features and advanced technologies that cater to the demands of varied environments.

One of the main features of the U39-LP1 is its propane-fueled operation, allowing it to generate an impressive amount of heat while remaining energy-efficient. The unit is designed with a remarkable heating capacity, making it ideal for larger spaces or for those chilly evenings where comfort is paramount. In contrast, the U39-NG1 operates on natural gas, appealing to homeowners looking for a more sustainable option. Both models allow for quick and effective heating, ensuring a cozy atmosphere within moments.

The technology embedded in both models reflects a commitment to top-tier performance. The advanced electronic ignition system provides reliability, ensuring seamless operation. The units also incorporate a built-in thermostat, which allows for precise control over the temperature, enhancing comfort while conserving energy. Furthermore, the U39 series features a sleek ceramic glass front that not only adds an aesthetic element but also enhances efficiency by radiating heat effectively into the room.

Another hallmark of the Regency U39 series is its design versatility. Both models are available in various finishes, enabling them to blend seamlessly into different décor styles, whether traditional, modern, or minimalist. The compact dimensions of these units ensure they fit effortlessly into a variety of spaces, from living rooms to basements.

Safety is also a significant focus with the U39-LP1 and U39-NG1. The units come equipped with a variety of safety features, including automatic shut-off and heat-resistant materials, ensuring peace of mind for users.

In summary, the Regency U39-LP1 and U39-NG1 models exemplify modern heating solutions characterized by efficiency, advanced technology, and stylish design. With their user-centric features and commitment to safety, these units are perfect additions for anyone seeking warmth and comfort in their homes. Whether powered by propane or natural gas, the U39 series continues to redefine the standard for home heating.