Regency U39-NG1, U39-LP1 installation manual Table of Contents

Page 3

TABLE OF CONTENTS

SAFETY LABEL

 

OPERATING INSTRUCTIONS

 

Copy of Safety Label

4

Operating Instructions

34

 

 

Shutdown Instructions

34

REQUIREMENTS

 

First Fire

34

 

 

Lighting Procedure

34

MA Code - CO Detector

5

Automatic Convection Fan Operation

35

Normal Operating Sounds of Gas Appliances

35

INSTALLATIONMAINTENANCE

Important Message

6

Specifi cations

6

Information For Mobile/Manufactured Homes

 

After First Sale

6

Before You Start

6

General Safety Information

7

Installation Checklist

7

Clearances To Combustibles

7

Manufactured Mobile Home Additional Requirements ..

8

Locating your Ultimate Gas Stove

8

Louver Installation

8

Combustion and Ventilation Air

8

Venting Introduction

8

Exterior Vent Terminal Locations

9

4” x 6-5/8” Rigid Pipe Cross Reference Chart

10

Rigid Pipe Venting Systems

12

Installation Precautions

13

Rigid Pipe Venting Arrangements

13

DV Stove Horizontal Vent Kit Installation

15

Dura-Vent Termination Kit

17

Converting a Class-A Metal Chimney or

 

Masonry Chimney to a Direct Vent System

21

Gas Connection

23

High Elevation

23

Conversion Kit# 731-969 from NG to LP

24

Conversion to Lower BTU Rating

27

Gas Pipe Pressure Testing

27

Aeration Adjustment

28

Log Set Installation

29

Wiring Diagram

32

Optional Wall Thermostat

33

Optional Remote Control

33

Final Check

33

Maintenance Instructions

36

General Vent Maintenance

36

Gold-Plated Doors

36

Log Replacement

37

Door Gasket

37

Latch Adjustment

37

Glass Replacement

37

Fan Maintenance

38

DC Sparker Battery Replacement

38

Removing Valve

39

PARTS LIST

 

Main Assembly

40

Burner & Log Assembly

41

Door Assemblies

42

WARRANTY

 

Warranty

43

Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove

3

Image 3
Contents Ultimate U39 Regency Table of Contents Copy of Safety Label for U39 Gas Stove Safety LabelMA Code CO Detector RequirementsBefore YOU Start InstallationSpecifications Important Message Save These InstructionsInstallation Checklist General Safety InformationClearances to Combustibles Locating Your Ultimate GAS Stove Louver InstallationVenting Introduction Manufactured Mobile Home Additional RequirementsExterior Vent Terminal Description 6-5/8 Rigid Pipe Cross Reference Chart6-5/8 Rigid Pipe Cross Reference Chart Rigid Pipe Venting Systems AlternateMination Caps Vent Restrictor Position Installation Precautions Rigid Pipe Venting ArrangementsSafety Precautions for Installer Horizontal Terminations for All Venting SystemsVertical Venting with Two 2 90o Elbows Horizontal Venting with Two 2 90o ElbowsDV Stove Horizontal Vent KIT Installation Capcanbemounted on DURA-VENT Venting Components Planning Your Dura-Vent InstallationMinimum components for a Dura-Vent Horizontal Installation DURA-VENT Termination KITSnorkel Terminations DURA-VENT Horizontal TerminationsDURA-VENT Vertical Terminations Below Grade InstallationCathedral Ceilings Offset ChartConverting a Factory Built Metal Chimney Approved for US Installations OnlySupport Extensions Round Rdse or Square Sqse GeneralConverting a Masonry Chimney System Data GAS ConnectionHigh Elevation System Data U39 with 40,000 BTULPG Conversion Kit Contains Qty Conversion KIT# 731-969 from NG to LPOnly Required for the U38 Green ground wire Propane Conversion Kit 730-922 Contains GAS Pipe Pressure TestingConversion to Lower BTU Rating Natural Gas Conversion Kit 730-920 ContainsU39 with 30,000 Btu/h Aeration AdjustmentValve Description U39 with 38,000 Btu/hLOG SET Installation B02-56 E02-45 G02 A02-65 Wiring Diagram 14 GA 16 GA 18 GA 20 GA 22 GA Final CheckShutdown Instructions Lighting ProcedureOperating Instructions Operating InstructionsNormal Operating Sounds GAS Appliances Automatic Convection FAN OperationCopy Of Lighting Plate Instructions GOLD-PLATED Doors MaintenanceMaintenance Instructions General Vent MaintenanceDoor Gasket LOG ReplacementLatch Adjustment Glass ReplacementTo Remove U39 Fan FAN MaintenanceDC Sparker Battery Replacement Alternate Fan AccessRemoving Valve Parts List Main AssemblyDescription Burner & LOG Assembly Door Assemblies Conditions WarrantyInstaller Please complete the following information

U39-LP1, U39-NG1 specifications

The Regency U39-LP1 and U39-NG1 are innovative heating appliances designed for modern homes, emphasizing both efficiency and style. These units encapsulate the essence of contemporary design while ensuring high-performance heating solutions. The U39 series stands out for its user-friendly features and advanced technologies that cater to the demands of varied environments.

One of the main features of the U39-LP1 is its propane-fueled operation, allowing it to generate an impressive amount of heat while remaining energy-efficient. The unit is designed with a remarkable heating capacity, making it ideal for larger spaces or for those chilly evenings where comfort is paramount. In contrast, the U39-NG1 operates on natural gas, appealing to homeowners looking for a more sustainable option. Both models allow for quick and effective heating, ensuring a cozy atmosphere within moments.

The technology embedded in both models reflects a commitment to top-tier performance. The advanced electronic ignition system provides reliability, ensuring seamless operation. The units also incorporate a built-in thermostat, which allows for precise control over the temperature, enhancing comfort while conserving energy. Furthermore, the U39 series features a sleek ceramic glass front that not only adds an aesthetic element but also enhances efficiency by radiating heat effectively into the room.

Another hallmark of the Regency U39 series is its design versatility. Both models are available in various finishes, enabling them to blend seamlessly into different décor styles, whether traditional, modern, or minimalist. The compact dimensions of these units ensure they fit effortlessly into a variety of spaces, from living rooms to basements.

Safety is also a significant focus with the U39-LP1 and U39-NG1. The units come equipped with a variety of safety features, including automatic shut-off and heat-resistant materials, ensuring peace of mind for users.

In summary, the Regency U39-LP1 and U39-NG1 models exemplify modern heating solutions characterized by efficiency, advanced technology, and stylish design. With their user-centric features and commitment to safety, these units are perfect additions for anyone seeking warmth and comfort in their homes. Whether powered by propane or natural gas, the U39 series continues to redefine the standard for home heating.