Regency U39-LP1, U39-NG1 FAN Maintenance, DC Sparker Battery Replacement, To Remove U39 Fan

Page 38

MAINTENANCE

7)Tighten side panels nuts using the following procedure:

a.tighten top & bottom outside corner nuts

(2)

b.tighten inside nuts (3)

c.tighten top & bottom inside corners (2)

8)Tighten the 10 nuts on center glass retainer.

9)Repeat step 7 for other side panel.

10)Replace new gasket by gluing it in place.

11)Install door onto stove and check the seal.

FAN MAINTENANCE

Ifyourfanrequiresmaintenanceorreplacement, access to the fan is through the plate on the rear wall of the fi rebox. NOTE: the unit MUST NOT be operated without the fan access panel securely in place and correctly sealed.

IMPORTANT: These fans collect a lot of dust from within your home. Ensure you maintain these fan motors on a regular basis by vacuuming out the fan squirrel cages, around the motor, and around the grills on the back of the stove.

IMPORTANT

Disconnect power supply

before servicing

WARNING:

Electrical Grounding

Instructions

This appliance is equipped with a three pronged (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug.

To Remove U39 Fan:

1)Unplug or disconnect power source to stove.

2)Remove all logs and the rear log support, then remove the 10 screws holding the access panel in place.

3)Unclip the black and white wires from the fan motor.

4)Open both side doors and gently pull the

ex pipe away from the center, otherwise the fan can catch on the fl ex pipe during installation and tear the pipe. Do not tear or damage the fl ex pipe.

Alternate Fan Access:

If the rear access cover is accessible,itcanberemovedto provide access to the fan.

5)Lift fan off of the 2 pins, tip back and pull through fi rebox opening. Disconnect the green ground wire from the right side of the fan as soon as you can reach it.

Replacing U39 Fan:

Reverse the above steps (1 - 5). If necessary install a new gasket before replacing the fan access panel. Make sure the fan wires and the ground wire are reattached.

Hint for pushing fan down onto pins - rub a bit of dish soap on the grommet so it will slide more easily onto the pin. Check to make sure the fan is seated properly on the pins - try to move the fan back and forth, there should be no noise, if there is check that the grommets haven't come loose.

DC SPARKER BATTERY

REPLACEMENT

The battery in the DC Spark box needs to be replaced annually.

1)Remove the DC Spark box from the back of the pedestal cover by removing the heat shield.

2)Remove the Heat Shield from the DC Spark Box.

3)Place 1 AA battery into the DC Spark Box by opening the battery compartment.

4)Reverse steps to put back in place.

38

Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove

Image 38
Contents Ultimate U39 Regency Table of Contents Safety Label Copy of Safety Label for U39 Gas StoveRequirements MA Code CO DetectorImportant Message Save These Instructions InstallationSpecifications Before YOU StartClearances to Combustibles Installation ChecklistGeneral Safety Information Manufactured Mobile Home Additional Requirements Louver InstallationVenting Introduction Locating Your Ultimate GAS StoveExterior Vent Terminal 6-5/8 Rigid Pipe Cross Reference Chart Description6-5/8 Rigid Pipe Cross Reference Chart Mination Caps Rigid Pipe Venting SystemsAlternate Horizontal Terminations for All Venting Systems Installation Precautions Rigid Pipe Venting ArrangementsSafety Precautions for Installer Vent Restrictor PositionHorizontal Venting with Two 2 90o Elbows Vertical Venting with Two 2 90o ElbowsDV Stove Horizontal Vent KIT Installation Capcanbemounted on DURA-VENT Termination KIT Planning Your Dura-Vent InstallationMinimum components for a Dura-Vent Horizontal Installation DURA-VENT Venting ComponentsDURA-VENT Horizontal Terminations Snorkel TerminationsBelow Grade Installation DURA-VENT Vertical TerminationsOffset Chart Cathedral CeilingsGeneral Approved for US Installations OnlySupport Extensions Round Rdse or Square Sqse Converting a Factory Built Metal ChimneyConverting a Masonry Chimney System Data U39 with 40,000 BTU GAS ConnectionHigh Elevation System DataConversion KIT# 731-969 from NG to LP LPG Conversion Kit Contains QtyOnly Required for the U38 Green ground wire Natural Gas Conversion Kit 730-920 Contains GAS Pipe Pressure TestingConversion to Lower BTU Rating Propane Conversion Kit 730-922 ContainsU39 with 38,000 Btu/h Aeration AdjustmentValve Description U39 with 30,000 Btu/hLOG SET Installation B02-56 E02-45 G02 A02-65 Wiring Diagram Final Check 14 GA 16 GA 18 GA 20 GA 22 GAOperating Instructions Lighting ProcedureOperating Instructions Shutdown InstructionsCopy Of Lighting Plate Instructions Normal Operating Sounds GAS AppliancesAutomatic Convection FAN Operation General Vent Maintenance MaintenanceMaintenance Instructions GOLD-PLATED DoorsGlass Replacement LOG ReplacementLatch Adjustment Door GasketAlternate Fan Access FAN MaintenanceDC Sparker Battery Replacement To Remove U39 FanRemoving Valve Description Parts ListMain Assembly Burner & LOG Assembly Door Assemblies Warranty ConditionsInstaller Please complete the following information

U39-LP1, U39-NG1 specifications

The Regency U39-LP1 and U39-NG1 are innovative heating appliances designed for modern homes, emphasizing both efficiency and style. These units encapsulate the essence of contemporary design while ensuring high-performance heating solutions. The U39 series stands out for its user-friendly features and advanced technologies that cater to the demands of varied environments.

One of the main features of the U39-LP1 is its propane-fueled operation, allowing it to generate an impressive amount of heat while remaining energy-efficient. The unit is designed with a remarkable heating capacity, making it ideal for larger spaces or for those chilly evenings where comfort is paramount. In contrast, the U39-NG1 operates on natural gas, appealing to homeowners looking for a more sustainable option. Both models allow for quick and effective heating, ensuring a cozy atmosphere within moments.

The technology embedded in both models reflects a commitment to top-tier performance. The advanced electronic ignition system provides reliability, ensuring seamless operation. The units also incorporate a built-in thermostat, which allows for precise control over the temperature, enhancing comfort while conserving energy. Furthermore, the U39 series features a sleek ceramic glass front that not only adds an aesthetic element but also enhances efficiency by radiating heat effectively into the room.

Another hallmark of the Regency U39 series is its design versatility. Both models are available in various finishes, enabling them to blend seamlessly into different décor styles, whether traditional, modern, or minimalist. The compact dimensions of these units ensure they fit effortlessly into a variety of spaces, from living rooms to basements.

Safety is also a significant focus with the U39-LP1 and U39-NG1. The units come equipped with a variety of safety features, including automatic shut-off and heat-resistant materials, ensuring peace of mind for users.

In summary, the Regency U39-LP1 and U39-NG1 models exemplify modern heating solutions characterized by efficiency, advanced technology, and stylish design. With their user-centric features and commitment to safety, these units are perfect additions for anyone seeking warmth and comfort in their homes. Whether powered by propane or natural gas, the U39 series continues to redefine the standard for home heating.