Regency P40-NG1, P40-LP1 installation manual Rigid Pipe Cross Reference Chart, 58DVA-16AB

Page 16

INSTALLATION

INSTALLATION

5” X 8” RIGID PIPE CROSS REFERENCE CHART

Components from different Manufacturers may not be mixed. Not All Rigid Pipe components are available directly from FPI.

Description

Simpson

 

Simpson

Selkirk

Metal-Fab®

®

Direct Vent GS®

 

Direct Vent Pro

 

Discontinued

Direct-Temp™

Sure Seal

 

 

 

 

 

6” Pipe Length, Galvanized

58DVA-06

 

1208

5DT-6

5D6

6” Pipe Length, Black

58DVA-06B

 

1208B

5DT-6B

5D6B

9” Pipe Length, Galvanized

58DVA-09

 

1207

5DT-9

N/A

9” Pipe Length, Black

58DVA-09B

 

1207B

5DT-9B

N/A

12” Pipe Length, Galvanized

58DVA-12

 

1206

5DT-12

5D12

12” Pipe Length, Black

58DVA-12B

 

1206B

5DT-12B

5D12B

18” Pipe Length, Galvanized

58DVA-18

 

58DVA-18

5DT-18

5D18

18” Pipe Length, Black

58DVA-18B - N/A from FPI

58DVA-18B - N/A from FPI

5DT-18B

5D18B

24” Pipe Length, Galvanized

58DVA-24

 

1204

5DT-24

5D24

24” Pipe Length, Black

58DVA-24B

 

1204B

5DT-24B

5D24B

36” Pipe Length, Galvanized

58DVA-36

 

1203

5DT-36

5D36

36” Pipe Length, Black

58DVA-36B

 

1203B

5DT-36B

5D36B

48” Pipe Length, Galvanized

58DVA-48

 

1202

5DT-48

5D48

48” Pipe Length, Black

58DVA-48B

 

1202B

5DT-48B

5D48B

60” Pipe Length, Galvanized

58DVA-60

 

58DVA-60

N/A

N/A

60” Pipe Length, Black

58DVA-60B - N/A from FPI

58DVA-60B - N/A from FPI

N/A

N/A

 

 

 

 

 

 

Adjustable Length 3”-10”, Galvanized

Adjustable Length 3”-10”, Black

Adjustable Length 11”-14”, Galvanized

Adjustable Length 11”-14”, Black

Adjustable Length 17”-24”, Galvanized

Adjustable Length 17”-24”, Black

Extension Pipe 8-1/2”, Galvanized

Extension Pipe 8-1/2”, Black

Extension Pipe 16”, Galvanized

Extension Pipe 16”, Black

N/A

N/A

Disc - See 58DV-08A Disc - See 58DV-08AB Disc - See 58DV-16A Disc - See 58DV-16AB 58DVA-08A - N/A from FPI

58DVA-08AB

58DVA-16A - N/A from FPI

58DVA-16AB

N/A

N/A

Disc - See 58DV-08A Disc - See 58DV-08AB Disc - See 58DV-16A Disc - See 58DV-16AB 58DVA-08A - N/A from FPI

58DVA-08AB

58DVA-16A - N/A from FPI

58DVA-16AB

N/A

N/A 5DT-AJ 5DT-AJB N/A N/A N/A N/A N/A N/A

5DAL

5DALB

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

45º Elbow, Galvanized

45º Elbow, Black

45º Elbow, Swivel, Galvanized 45º Elbow, Swivel, Black

90º Elbow, Galvanized

90º Elbow, Black

90º Elbow, Swivel, Galvanized 90º Elbow, Swivel, Black

90º Starter Elbow, Swivel, Galvanized* Adaptor*

58DVA-E45

58DVA-E45B

Disc - See 58DVA-E45 Disc - See 58DVA-E45B 58DVA-E90 58DVA-E90B

Disc - See 58DVA-E90

Disc - See 58DVA-E90B

N/A

N/A

1245

1245B

1245G

1245BG 58DVA-E90 58DVA-E90B

Disc - See 58DVA-E90 Disc - See 58DVA-E90B

N/A

N/A

5DT-EL45 5DT-EL45B N/A

N/A 5DT-EL90S 5DT-EL90SB N/A

N/A

N/A

N/A

N/A

N/A

5D45L

5D45LB

N/A

N/A

5D90L

5D90LB

5D90A

5DDA

Ceiling Support

Cathedral Support Box

Wall Support/Band

Offset Support

Wall Thimble, Black

Wall Thimble Support Box/Ceiling Support

Firestop Spacer

Trim Plate, Black

58DVA-DC

58DVA-CS

58DVA-WS

58DVA-ES - N/A from FPI

58DVA-WT

58DVA-DC - N/A from FPI

58DVA-FS

58DAV-WFS

1240

1241

1288

N/A

1247

N/A

1263

1242

5DT-CS 5DT-CSS 5DT-WS/B 5DT-OS 5DT-WT N/A 5DT-FS 5DT-TP

5DSP

5DRS

5DWS

N/A

5DWT

N/A

5DFS

5DCP

16

Regency® P40-1 Direct Vent Gas Fireplace

Image 16
Contents P40 Gas Fireplace Manufactured Mobile Home Requirements Information for MOBILE/MANUFACTURED Homes After First SaleTable of Contents Installation Copy of Safety LabelMA Code CO Detector For the State of Massachusetts onlyDimensions General Safety Information Installation ChecklistImportant Message Before YOU StartLocating Your GAS Fireplace Heatwave Duct KITHeat Release KIT Hearth RequirementsClearances Mantel Clearances Mantel LEG ClearancesP40 Fireplace P40Full Screen Door Facing Requirements Framing & FinishingHeight = 42-1/2 plus height of hearth Venting Introduction Unit Assembly Prior to InstallationVent Restrictor Position Exterior Vent Termination Requirements Venting Arrangements Horizontal Termination FlexBasic Horizontal & Vertical Terminations Rigid Pipe Venting SystemsHorizontal Termination 8 Rigid Pipe Cross Reference Chart 58DVA-16ABOffset Pipe Selection 58DVA-RDAllowable Horizontal Terminations Horizontal Feet Vertical Height FeetOption + H1 Option + V1 H + H1Option Option + H1 V +Allowable Vertical Terminations Vent must be supported at offsetsUnit Installation with Horizontal Termination Arrow on the vent cap should be pointing upUnit Installation With Vertical Termination This allows for small adjustmentsDiagram Minimum VentUnit Installation Astrocap XL DimensionsGAS Line Installation Pilot AdjustmentHigh Elevation P40-NG1 System DataGAS Pipe Pressure Testing BACK-UP Battery InstallationUnplug the power source Power ModuleConversion KIT #502-969 from NG to LP LP Conversion Kit Contains Qty DescriptionModulating Coil Control ModuleJ9 Jumper Conversion KIT #502-966 from LP to NG NG Conversion Kit Contains Qty DescriptionJ9 Jumper Location Brick Panel Installation Back Brick Panel Brick Panels Completely InstalledEnsure that the logs are not in the unit Top Brick Panel03-32 LOG SET Installation03-40 03-33 03-34 03-341st Log Stand Post 03-46 03-33 03-33 03-46 03-3603-37 03-36 03-3703-46 03-36 03-3803-36 03-32 03-37 03-34 03-40 03-46 03-47 03-382Aeration Adjustment Installing the Manual Control BoxStandard Flush Door Flush LouversFinishing Trim Wiring DiagramDo not cut the ground terminal off under any circumstances Full Screen Door Frame Installation Full Screen DoorsInstallation Upper Air RegisterLighting Procedure Shutdown ProcedureMatching Remote Handset & Control BOX ID Code Operating InstructionsFirst Fire Operation During Power OutageDo not Burn the Appliance Without the Glass Front in Place Summary Controls Normal Operating Sounds GAS AppliancesSTOP! Read the safety information above on this label For Your Safety Read Before LightingCopy of Lighting Plate Instructions Maintenance Instructions General Vent MaintenanceLOG Replacement Thermopile ThermocoupleDoor Glass FAN Replacement Glass ReplacementValve Replacement WireLog Stand Solenoid Valve Compression FittingsDC Sparker Replacement Power Module ReplacementWa & Wb Wires Ring TabsBackup Battery Replacement Control Module ReplacementHeat Shield Parts List Main AssemblyParts List Valve Tray AssemblyFlush Door & Louvers Regency P40-1 Direct Vent Gas Fireplace Regency P40-1 Direct Vent Gas Fireplace Regency P40-1 Direct Vent Gas Fireplace Warranty Installer Please complete the following information

P40-LP1, P40-NG1 specifications

The Regency P40-LP1 and P40-NG1 are notable advancements in the realm of modern technology, particularly designed for energy efficiency and enhanced performance in various applications. These two models cater to the diverse needs of industries striving for both sustainability and productivity.

The P40-LP1 is engineered with a focus on low-pressure applications, utilizing cutting-edge technology to ensure optimal performance in energy consumption. This model features an advanced energy management system that intelligently adjusts power usage based on demand, which not only reduces operational costs but also minimizes the environmental impact. Its compact design and lightweight materials allow for easy installation in various settings, making it a versatile option for multiple industries.

On the other hand, the P40-NG1 is tailored for natural gas applications, making it an ideal choice for environments where natural gas is the primary energy source. This model is equipped with high-efficiency burners that maximize combustion efficiency, producing fewer emissions compared to traditional systems. The P40-NG1 also incorporates an integrated control system, providing users with real-time data monitoring to optimize performance and facilitate preventative maintenance.

Both models are constructed with durable materials designed to withstand harsh operating conditions, ensuring longevity and reliability. Advanced insulation technology further enhances their efficiency by reducing heat loss, allowing these systems to maintain consistent performance over extended periods.

A standout feature of the P40 series is its commitment to user-friendliness. The intuitive interface allows operators to easily navigate settings and access critical system information with minimal training. Additionally, these units are compatible with smart technologies, enabling seamless integration into existing infrastructure for enhanced operational oversight.

In summary, the Regency P40-LP1 and P40-NG1 embody the future of energy solutions, combining efficiency, adaptability, and user-focused design. Whether it’s for low-pressure or natural gas applications, these products deliver reliable performance while adhering to environmental standards. With ongoing advancements in their technology, the P40 series stands as a testament to Regency’s dedication to innovation and sustainability in the energy sector.