Regency P40-NG1, P40-LP1 installation manual Venting Arrangements, Horizontal Termination Flex

Page 14

INSTALLATION

INSTALLATION

VENTING ARRANGEMENTS

HORIZONTAL TERMINATION (FLEX)

Regency® Direct Vent System

These venting systems, in combination with the P40 Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in "Exterior Vent Termination Requirements" section.

Regency® Direct Vent (Flex) System

 

AstroCap XL

Termination Kit (Part# 946-618) includes all

 

 

(Part# 946-623/P)

the parts needed to install the P40 with a

 

maximum run of 6 feet.

 

 

1)

8" dia. flexible liner (6 ft. length)

 

 

2)

5" dia. flexible liner (6 ft. length)

 

 

3)

spring spacers (4)

Wall Thimble

 

4)

thimble

 

(required in Canada only)

5)

AstroCap XL termination cap (1)

6)

screws (12)

 

Vinyl Siding

7)

tube of Mill Pac (1)

 

 

Standoff

8)

plated screws (8)

 

 

 

9)

screws #8 x 1-1/2" Drill Point,

5” dia. flue pipe

 

 

Stainless Steel (4)

 

 

10) vinyl siding standoff

8" dia.

 

 

 

spring spacer

If longer runs are needed, the Regency® Direct

Flue pipe

 

Vent system (Flex) Part# 946-616 includes all the parts needed to install the P40 with a maximum 10' run.

1) 8" dia. flexible liner (10 ft. length)

2) 5" dia. flexible liner (10 ft. length)

3)spring spacers (7)

4) thimble (2)

5)AstroCap XL termination cap (1)

6)screws (12)

7)tube of Mill Pac (1)

8)plated screws (8)

9)screws #8 x 1-1/2" Drill Point,

Stainless Steel (4)

10) vinyl siding standoff

Notes:

1)Liner sections should be continuous without any joints or seams.

2)Only Flex pipe purchased from FPI may be used for Flex installations.

3)Horizontal vent must be supported every 3 feet. (For 10' flex kit 946-616 only.)

14

Regency® P40-1 Direct Vent Gas Fireplace

Image 14
Contents P40 Gas Fireplace Manufactured Mobile Home Requirements Information for MOBILE/MANUFACTURED Homes After First SaleTable of Contents Installation Copy of Safety LabelMA Code CO Detector For the State of Massachusetts onlyDimensions Important Message General Safety InformationInstallation Checklist Before YOU StartHeat Release KIT Locating Your GAS FireplaceHeatwave Duct KIT Hearth RequirementsClearances P40 Fireplace Mantel ClearancesMantel LEG Clearances P40Height = 42-1/2 plus height of hearth Framing & FinishingFull Screen Door Facing Requirements Vent Restrictor Position Unit Assembly Prior to InstallationVenting Introduction Exterior Vent Termination Requirements Venting Arrangements Horizontal Termination FlexHorizontal Termination Rigid Pipe Venting SystemsBasic Horizontal & Vertical Terminations 8 Rigid Pipe Cross Reference Chart 58DVA-16ABOffset Pipe Selection 58DVA-RDAllowable Horizontal Terminations Horizontal Feet Vertical Height FeetOption + H1 Option + V1 H + H1Option Option + H1 V +Allowable Vertical Terminations Vent must be supported at offsetsUnit Installation with Horizontal Termination Arrow on the vent cap should be pointing upDiagram Unit Installation With Vertical TerminationThis allows for small adjustments Minimum VentUnit Installation Astrocap XL DimensionsHigh Elevation GAS Line InstallationPilot Adjustment P40-NG1 System DataUnplug the power source GAS Pipe Pressure TestingBACK-UP Battery Installation Power ModuleConversion KIT #502-969 from NG to LP LP Conversion Kit Contains Qty DescriptionJ9 Jumper Control ModuleModulating Coil Conversion KIT #502-966 from LP to NG NG Conversion Kit Contains Qty DescriptionJ9 Jumper Location Ensure that the logs are not in the unit Brick Panel InstallationBack Brick Panel Brick Panels Completely Installed Top Brick Panel03-40 LOG SET Installation03-32 1st Log Stand Post 03-3403-33 03-34 03-37 03-46 03-3303-33 03-46 03-36 03-36 03-3703-36 03-32 03-37 03-46 03-3603-38 03-34 03-40 03-46 03-47 03-382Standard Flush Door Aeration AdjustmentInstalling the Manual Control Box Flush LouversDo not cut the ground terminal off under any circumstances Wiring DiagramFinishing Trim Full Screen Door Frame Installation Full Screen DoorsInstallation Upper Air RegisterMatching Remote Handset & Control BOX ID Code Lighting ProcedureShutdown Procedure Operating InstructionsDo not Burn the Appliance Without the Glass Front in Place Operation During Power OutageFirst Fire Summary Controls Normal Operating Sounds GAS AppliancesCopy of Lighting Plate Instructions For Your Safety Read Before LightingSTOP! Read the safety information above on this label LOG Replacement Maintenance InstructionsGeneral Vent Maintenance Thermopile ThermocoupleDoor Glass FAN Replacement Glass ReplacementLog Stand Valve ReplacementWire Solenoid Valve Compression FittingsWa & Wb Wires DC Sparker ReplacementPower Module Replacement Ring TabsHeat Shield Control Module ReplacementBackup Battery Replacement Parts List Main AssemblyParts List Valve Tray AssemblyFlush Door & Louvers Regency P40-1 Direct Vent Gas Fireplace Regency P40-1 Direct Vent Gas Fireplace Regency P40-1 Direct Vent Gas Fireplace Warranty Installer Please complete the following information

P40-LP1, P40-NG1 specifications

The Regency P40-LP1 and P40-NG1 are notable advancements in the realm of modern technology, particularly designed for energy efficiency and enhanced performance in various applications. These two models cater to the diverse needs of industries striving for both sustainability and productivity.

The P40-LP1 is engineered with a focus on low-pressure applications, utilizing cutting-edge technology to ensure optimal performance in energy consumption. This model features an advanced energy management system that intelligently adjusts power usage based on demand, which not only reduces operational costs but also minimizes the environmental impact. Its compact design and lightweight materials allow for easy installation in various settings, making it a versatile option for multiple industries.

On the other hand, the P40-NG1 is tailored for natural gas applications, making it an ideal choice for environments where natural gas is the primary energy source. This model is equipped with high-efficiency burners that maximize combustion efficiency, producing fewer emissions compared to traditional systems. The P40-NG1 also incorporates an integrated control system, providing users with real-time data monitoring to optimize performance and facilitate preventative maintenance.

Both models are constructed with durable materials designed to withstand harsh operating conditions, ensuring longevity and reliability. Advanced insulation technology further enhances their efficiency by reducing heat loss, allowing these systems to maintain consistent performance over extended periods.

A standout feature of the P40 series is its commitment to user-friendliness. The intuitive interface allows operators to easily navigate settings and access critical system information with minimal training. Additionally, these units are compatible with smart technologies, enabling seamless integration into existing infrastructure for enhanced operational oversight.

In summary, the Regency P40-LP1 and P40-NG1 embody the future of energy solutions, combining efficiency, adaptability, and user-focused design. Whether it’s for low-pressure or natural gas applications, these products deliver reliable performance while adhering to environmental standards. With ongoing advancements in their technology, the P40 series stands as a testament to Regency’s dedication to innovation and sustainability in the energy sector.