INSTALLATION

FULL SCREEN DOORS

INSTALLATION

1)Before beginning the installation; if already installed, remove the Top and Bottom Louvers, the Manual Control Box and the Glass Door from the unit. Refer to the manual for instructions and reverse the steps (See Page 32).

2)Remove the Screen Doors from the Full Screen Door Frame by fully opening the doors and lifting up off of the hinges. See important note in step 9.

3)Install the Hinges to the Hinge Brackets on the left and right side of the bottom of the outer frame, se- cure using 2x #8 Self Tapping Phillips Screws per hinge.

4)Full Screen Door Frame Installation

a)Before attaching the Full Screen Door Frame to the unit, loosen the left and right side #8 Self Tapping Phillips Screws located on the inside top of the outer frame of the appliance. Also remove the center screw.

b)Slide the cut-outs in the Top and Bottom Flange of the Full Screen Door Frame under the screw heads which were loosened in step 4a. Once the Frame is in place, tighten the screws to secure. Also re-secure the top center screw through the oblong hole.

Full Screen

Door Frame

Cut Outs

Remove the center screw

Inside

Top of

Outer

Frame

Loosen these

four screws

Leave these two screws secured

Oblong

Hole

Top Flange

Bottom Flange

Cut Outs

Rear view of Full

Screen Door

Frame Shown

Leave these two screws secured

NOTE: Should the finished wall protrude beyond the face of the unit, you can accommodate up to 1/2" discrepancy in depth.

38

Regency® P40-1 Direct Vent Gas Fireplace

Image 38
Contents P40 Gas Fireplace Manufactured Mobile Home Requirements Information for MOBILE/MANUFACTURED Homes After First SaleTable of Contents Installation Copy of Safety LabelMA Code CO Detector For the State of Massachusetts onlyDimensions Important Message General Safety InformationInstallation Checklist Before YOU StartHeat Release KIT Locating Your GAS FireplaceHeatwave Duct KIT Hearth RequirementsClearances P40 Fireplace Mantel ClearancesMantel LEG Clearances P40Height = 42-1/2 plus height of hearth Framing & FinishingFull Screen Door Facing Requirements Vent Restrictor Position Unit Assembly Prior to InstallationVenting Introduction Exterior Vent Termination Requirements Venting Arrangements Horizontal Termination FlexHorizontal Termination Rigid Pipe Venting SystemsBasic Horizontal & Vertical Terminations 8 Rigid Pipe Cross Reference Chart 58DVA-16ABOffset Pipe Selection 58DVA-RDAllowable Horizontal Terminations Horizontal Feet Vertical Height FeetOption + H1 Option + V1 H + H1Option Option + H1 V +Allowable Vertical Terminations Vent must be supported at offsetsUnit Installation with Horizontal Termination Arrow on the vent cap should be pointing upDiagram Unit Installation With Vertical TerminationThis allows for small adjustments Minimum VentUnit Installation Astrocap XL DimensionsHigh Elevation GAS Line InstallationPilot Adjustment P40-NG1 System DataUnplug the power source GAS Pipe Pressure TestingBACK-UP Battery Installation Power ModuleConversion KIT #502-969 from NG to LP LP Conversion Kit Contains Qty DescriptionJ9 Jumper Control ModuleModulating Coil Conversion KIT #502-966 from LP to NG NG Conversion Kit Contains Qty DescriptionJ9 Jumper Location Ensure that the logs are not in the unit Brick Panel InstallationBack Brick Panel Brick Panels Completely Installed Top Brick Panel03-40 LOG SET Installation03-32 1st Log Stand Post 03-3403-33 03-34 03-37 03-46 03-3303-33 03-46 03-36 03-36 03-3703-36 03-32 03-37 03-46 03-3603-38 03-34 03-40 03-46 03-47 03-382Standard Flush Door Aeration AdjustmentInstalling the Manual Control Box Flush LouversDo not cut the ground terminal off under any circumstances Wiring DiagramFinishing Trim Full Screen Door Frame Installation Full Screen DoorsInstallation Upper Air RegisterMatching Remote Handset & Control BOX ID Code Lighting ProcedureShutdown Procedure Operating InstructionsDo not Burn the Appliance Without the Glass Front in Place Operation During Power OutageFirst Fire Summary Controls Normal Operating Sounds GAS AppliancesCopy of Lighting Plate Instructions For Your Safety Read Before LightingSTOP! Read the safety information above on this label LOG Replacement Maintenance InstructionsGeneral Vent Maintenance Thermopile ThermocoupleDoor Glass FAN Replacement Glass ReplacementLog Stand Valve ReplacementWire Solenoid Valve Compression FittingsWa & Wb Wires DC Sparker ReplacementPower Module Replacement Ring TabsHeat Shield Control Module ReplacementBackup Battery Replacement Parts List Main AssemblyParts List Valve Tray AssemblyFlush Door & Louvers Regency P40-1 Direct Vent Gas Fireplace Regency P40-1 Direct Vent Gas Fireplace Regency P40-1 Direct Vent Gas Fireplace Warranty Installer Please complete the following information

P40-LP1, P40-NG1 specifications

The Regency P40-LP1 and P40-NG1 are notable advancements in the realm of modern technology, particularly designed for energy efficiency and enhanced performance in various applications. These two models cater to the diverse needs of industries striving for both sustainability and productivity.

The P40-LP1 is engineered with a focus on low-pressure applications, utilizing cutting-edge technology to ensure optimal performance in energy consumption. This model features an advanced energy management system that intelligently adjusts power usage based on demand, which not only reduces operational costs but also minimizes the environmental impact. Its compact design and lightweight materials allow for easy installation in various settings, making it a versatile option for multiple industries.

On the other hand, the P40-NG1 is tailored for natural gas applications, making it an ideal choice for environments where natural gas is the primary energy source. This model is equipped with high-efficiency burners that maximize combustion efficiency, producing fewer emissions compared to traditional systems. The P40-NG1 also incorporates an integrated control system, providing users with real-time data monitoring to optimize performance and facilitate preventative maintenance.

Both models are constructed with durable materials designed to withstand harsh operating conditions, ensuring longevity and reliability. Advanced insulation technology further enhances their efficiency by reducing heat loss, allowing these systems to maintain consistent performance over extended periods.

A standout feature of the P40 series is its commitment to user-friendliness. The intuitive interface allows operators to easily navigate settings and access critical system information with minimal training. Additionally, these units are compatible with smart technologies, enabling seamless integration into existing infrastructure for enhanced operational oversight.

In summary, the Regency P40-LP1 and P40-NG1 embody the future of energy solutions, combining efficiency, adaptability, and user-focused design. Whether it’s for low-pressure or natural gas applications, these products deliver reliable performance while adhering to environmental standards. With ongoing advancements in their technology, the P40 series stands as a testament to Regency’s dedication to innovation and sustainability in the energy sector.