Regency P40-NG1, P40-LP1 installation manual Installation, Copy of Safety Label

Page 4

INSTALLATION

INSTALLATION

This is a copy of the label that accompanies each P40-NG1 and P40-LP1 Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review.

NOTE: Regency® units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.

Copy of Safety Label

For the State of Massachusetts, installation and repair must be done by a plumber or gasfitter licensed in the Commonwealth of Massachusetts.

For the State of Massachusetts, flexible connectors shall not exceed 36 inches in length.

For the State of Massachusetts, the appli- ances individual manual shut-off must be a t-handle type valve.

The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm with battery back up in the same room where the gas appliance is installed.

4

Regency® P40-1 Direct Vent Gas Fireplace

Image 4
Contents P40 Gas Fireplace Manufactured Mobile Home Requirements Information for MOBILE/MANUFACTURED Homes After First SaleTable of Contents Installation Copy of Safety LabelMA Code CO Detector For the State of Massachusetts onlyDimensions General Safety Information Installation ChecklistImportant Message Before YOU StartLocating Your GAS Fireplace Heatwave Duct KITHeat Release KIT Hearth RequirementsClearances Mantel Clearances Mantel LEG ClearancesP40 Fireplace P40Full Screen Door Facing Requirements Framing & FinishingHeight = 42-1/2 plus height of hearth Venting Introduction Unit Assembly Prior to InstallationVent Restrictor Position Exterior Vent Termination Requirements Venting Arrangements Horizontal Termination FlexBasic Horizontal & Vertical Terminations Rigid Pipe Venting SystemsHorizontal Termination 8 Rigid Pipe Cross Reference Chart 58DVA-16ABOffset Pipe Selection 58DVA-RDAllowable Horizontal Terminations Horizontal Feet Vertical Height FeetOption + H1 Option + V1 H + H1Option Option + H1 V +Allowable Vertical Terminations Vent must be supported at offsetsUnit Installation with Horizontal Termination Arrow on the vent cap should be pointing upUnit Installation With Vertical Termination This allows for small adjustmentsDiagram Minimum VentUnit Installation Astrocap XL DimensionsGAS Line Installation Pilot AdjustmentHigh Elevation P40-NG1 System DataGAS Pipe Pressure Testing BACK-UP Battery InstallationUnplug the power source Power ModuleConversion KIT #502-969 from NG to LP LP Conversion Kit Contains Qty DescriptionModulating Coil Control ModuleJ9 Jumper Conversion KIT #502-966 from LP to NG NG Conversion Kit Contains Qty DescriptionJ9 Jumper Location Brick Panel Installation Back Brick Panel Brick Panels Completely InstalledEnsure that the logs are not in the unit Top Brick Panel03-32 LOG SET Installation03-40 03-33 03-34 03-341st Log Stand Post 03-46 03-33 03-33 03-46 03-3603-37 03-36 03-3703-46 03-36 03-3803-36 03-32 03-37 03-34 03-40 03-46 03-47 03-382Aeration Adjustment Installing the Manual Control BoxStandard Flush Door Flush LouversFinishing Trim Wiring DiagramDo not cut the ground terminal off under any circumstances Full Screen Door Frame Installation Full Screen DoorsInstallation Upper Air RegisterLighting Procedure Shutdown ProcedureMatching Remote Handset & Control BOX ID Code Operating InstructionsFirst Fire Operation During Power OutageDo not Burn the Appliance Without the Glass Front in Place Summary Controls Normal Operating Sounds GAS AppliancesSTOP! Read the safety information above on this label For Your Safety Read Before LightingCopy of Lighting Plate Instructions Maintenance Instructions General Vent MaintenanceLOG Replacement Thermopile ThermocoupleDoor Glass FAN Replacement Glass ReplacementValve Replacement WireLog Stand Solenoid Valve Compression FittingsDC Sparker Replacement Power Module ReplacementWa & Wb Wires Ring TabsBackup Battery Replacement Control Module ReplacementHeat Shield Parts List Main AssemblyParts List Valve Tray AssemblyFlush Door & Louvers Regency P40-1 Direct Vent Gas Fireplace Regency P40-1 Direct Vent Gas Fireplace Regency P40-1 Direct Vent Gas Fireplace Warranty Installer Please complete the following information

P40-LP1, P40-NG1 specifications

The Regency P40-LP1 and P40-NG1 are notable advancements in the realm of modern technology, particularly designed for energy efficiency and enhanced performance in various applications. These two models cater to the diverse needs of industries striving for both sustainability and productivity.

The P40-LP1 is engineered with a focus on low-pressure applications, utilizing cutting-edge technology to ensure optimal performance in energy consumption. This model features an advanced energy management system that intelligently adjusts power usage based on demand, which not only reduces operational costs but also minimizes the environmental impact. Its compact design and lightweight materials allow for easy installation in various settings, making it a versatile option for multiple industries.

On the other hand, the P40-NG1 is tailored for natural gas applications, making it an ideal choice for environments where natural gas is the primary energy source. This model is equipped with high-efficiency burners that maximize combustion efficiency, producing fewer emissions compared to traditional systems. The P40-NG1 also incorporates an integrated control system, providing users with real-time data monitoring to optimize performance and facilitate preventative maintenance.

Both models are constructed with durable materials designed to withstand harsh operating conditions, ensuring longevity and reliability. Advanced insulation technology further enhances their efficiency by reducing heat loss, allowing these systems to maintain consistent performance over extended periods.

A standout feature of the P40 series is its commitment to user-friendliness. The intuitive interface allows operators to easily navigate settings and access critical system information with minimal training. Additionally, these units are compatible with smart technologies, enabling seamless integration into existing infrastructure for enhanced operational oversight.

In summary, the Regency P40-LP1 and P40-NG1 embody the future of energy solutions, combining efficiency, adaptability, and user-focused design. Whether it’s for low-pressure or natural gas applications, these products deliver reliable performance while adhering to environmental standards. With ongoing advancements in their technology, the P40 series stands as a testament to Regency’s dedication to innovation and sustainability in the energy sector.