Regency P40-NG1, P40-LP1 Control Module Replacement, Backup Battery Replacement, Heat Shield

Page 48

MAINTENANCE

CONTROL MODULE

REPLACEMENT

1)Unplug the power source.

2)Remove the Power Module by lifting it up off of the velcro and pull out.

Power Module

3)Remove the Control Module by lifting it up off of the velcro and pull out.

Control Module

4)Remove the Heat Shield from the Control Module by removing the 2 screws.

Heat Shield

5)Unplug all wire harnesses and manual control box cable plugged into the Control module.

6)Replace the Control Module and reverse steps to re-install.

BACKUP BATTERY

REPLACEMENT

(within Power Module)

NOTE: The 9V battery operates the rear burner under power outage conditions.

The AA battery operates the DC Sparker for lighting the pilot.

1)Unplug the power source.

2)Remove the Power Module by lifting it up off of the velcro and pull out.

Power Module

3)Remove the Power Module cover by removing the 2 screws, one on each side of the box.

MAINTENANCE

4)Replace the 9V and AA battery and reverse steps to re-install.

48

Regency® P40-1 Direct Vent Gas Fireplace

Image 48
Contents P40 Gas Fireplace Manufactured Mobile Home Requirements Information for MOBILE/MANUFACTURED Homes After First SaleTable of Contents Installation Copy of Safety LabelMA Code CO Detector For the State of Massachusetts onlyDimensions General Safety Information Installation ChecklistImportant Message Before YOU StartLocating Your GAS Fireplace Heatwave Duct KITHeat Release KIT Hearth RequirementsClearances Mantel Clearances Mantel LEG ClearancesP40 Fireplace P40Framing & Finishing Full Screen Door Facing RequirementsHeight = 42-1/2 plus height of hearth Unit Assembly Prior to Installation Venting IntroductionVent Restrictor Position Exterior Vent Termination Requirements Venting Arrangements Horizontal Termination FlexRigid Pipe Venting Systems Basic Horizontal & Vertical TerminationsHorizontal Termination 8 Rigid Pipe Cross Reference Chart 58DVA-16ABOffset Pipe Selection 58DVA-RDAllowable Horizontal Terminations Horizontal Feet Vertical Height FeetOption + H1 Option + V1 H + H1Option Option + H1 V +Allowable Vertical Terminations Vent must be supported at offsetsUnit Installation with Horizontal Termination Arrow on the vent cap should be pointing upUnit Installation With Vertical Termination This allows for small adjustmentsDiagram Minimum VentUnit Installation Astrocap XL DimensionsGAS Line Installation Pilot AdjustmentHigh Elevation P40-NG1 System DataGAS Pipe Pressure Testing BACK-UP Battery InstallationUnplug the power source Power ModuleConversion KIT #502-969 from NG to LP LP Conversion Kit Contains Qty DescriptionControl Module Modulating CoilJ9 Jumper Conversion KIT #502-966 from LP to NG NG Conversion Kit Contains Qty DescriptionJ9 Jumper Location Brick Panel Installation Back Brick Panel Brick Panels Completely InstalledEnsure that the logs are not in the unit Top Brick PanelLOG SET Installation 03-3203-40 03-34 03-33 03-341st Log Stand Post 03-46 03-33 03-33 03-46 03-3603-37 03-36 03-3703-46 03-36 03-3803-36 03-32 03-37 03-34 03-40 03-46 03-47 03-382Aeration Adjustment Installing the Manual Control BoxStandard Flush Door Flush LouversWiring Diagram Finishing TrimDo not cut the ground terminal off under any circumstances Full Screen Door Frame Installation Full Screen DoorsInstallation Upper Air RegisterLighting Procedure Shutdown ProcedureMatching Remote Handset & Control BOX ID Code Operating InstructionsOperation During Power Outage First FireDo not Burn the Appliance Without the Glass Front in Place Summary Controls Normal Operating Sounds GAS AppliancesFor Your Safety Read Before Lighting STOP! Read the safety information above on this labelCopy of Lighting Plate Instructions Maintenance Instructions General Vent MaintenanceLOG Replacement Thermopile ThermocoupleDoor Glass FAN Replacement Glass ReplacementValve Replacement WireLog Stand Solenoid Valve Compression FittingsDC Sparker Replacement Power Module ReplacementWa & Wb Wires Ring TabsControl Module Replacement Backup Battery ReplacementHeat Shield Parts List Main AssemblyParts List Valve Tray AssemblyFlush Door & Louvers Regency P40-1 Direct Vent Gas Fireplace Regency P40-1 Direct Vent Gas Fireplace Regency P40-1 Direct Vent Gas Fireplace Warranty Installer Please complete the following information

P40-LP1, P40-NG1 specifications

The Regency P40-LP1 and P40-NG1 are notable advancements in the realm of modern technology, particularly designed for energy efficiency and enhanced performance in various applications. These two models cater to the diverse needs of industries striving for both sustainability and productivity.

The P40-LP1 is engineered with a focus on low-pressure applications, utilizing cutting-edge technology to ensure optimal performance in energy consumption. This model features an advanced energy management system that intelligently adjusts power usage based on demand, which not only reduces operational costs but also minimizes the environmental impact. Its compact design and lightweight materials allow for easy installation in various settings, making it a versatile option for multiple industries.

On the other hand, the P40-NG1 is tailored for natural gas applications, making it an ideal choice for environments where natural gas is the primary energy source. This model is equipped with high-efficiency burners that maximize combustion efficiency, producing fewer emissions compared to traditional systems. The P40-NG1 also incorporates an integrated control system, providing users with real-time data monitoring to optimize performance and facilitate preventative maintenance.

Both models are constructed with durable materials designed to withstand harsh operating conditions, ensuring longevity and reliability. Advanced insulation technology further enhances their efficiency by reducing heat loss, allowing these systems to maintain consistent performance over extended periods.

A standout feature of the P40 series is its commitment to user-friendliness. The intuitive interface allows operators to easily navigate settings and access critical system information with minimal training. Additionally, these units are compatible with smart technologies, enabling seamless integration into existing infrastructure for enhanced operational oversight.

In summary, the Regency P40-LP1 and P40-NG1 embody the future of energy solutions, combining efficiency, adaptability, and user-focused design. Whether it’s for low-pressure or natural gas applications, these products deliver reliable performance while adhering to environmental standards. With ongoing advancements in their technology, the P40 series stands as a testament to Regency’s dedication to innovation and sustainability in the energy sector.