Regency P40-LP1, P40-NG1 Rigid Pipe Venting Systems, Basic Horizontal & Vertical Terminations

Page 15

INSTALLATION

RIGID PIPE VENTING SYSTEMS

BASIC HORIZONTAL & VERTICAL TERMINATIONS

Rigid Pipe Vent Systems offer a complete line of component parts for installation of both horizontal and vertical installations. Many items are offered in decorative black, as well as galvanized finish.

INSTALLATION

The minimum components required for a basic horizontal termination are:

1Horizontal Termination Cap

190o Elbow

1Rigid Pipe Adaptor

1Wall Thimble (Canada only)

1Length of pipe to suit wall thickness

The minimum components required for a basic vertical termination are:

1Vertical Termination Cap

1Rigid Pipe Adaptor

1Lengths of pipe to adequately penetrate roof

1Ceiling Firestop

1Flashing

1Storm Collar

Wall thickness is measured from the back standoffs to the inside mounting surface of termination cap. For siding other than vinyl furring strips may be used, instead of the vinyl siding standoff, to create a level surface to mount the vent terminal. The Terminal must not be recessed into siding. Measure the wall thickness including furring strips.

If a Vinyl Siding Standoff is required (it must be used with vinyl siding), measure to outside surface of wall without siding and add 2 inches.

When using Rigid Vent other than

Simpson Dura-Vent, 3 screws must be used to secure rigid pipe to adaptor.

Vertical

Terminal

Storm Collar

 

Vinyl Siding

Flashing

Standoff

AstroCap XL

Ceiling FirestopTermination Cap (946-623/P)

 

 

Wall Thimble

 

 

(required in Canada only)

Pipe Length

Adj.Pipe Length

 

 

11" - 14-5/8"

90o Elbow

 

 

24" Pipe

 

 

Length

 

Alternate

 

 

Horizontal Termination

Rigid Pipe Adapter

Caps

 

(770-994)

 

WARNING:

Do not combine venting components from different venting systems.

Exception: However, use of the the AstroCap XLTM and FPI Riser is acceptable with all systems.

This product has been evaluated by Intertek for using a Rigid Pipe Adaptor in conjunction with Duravent Direct-Vent GS and Selkirk Direct- Temp systems. Use of these systems with the Rigid Pipe adaptor is deemed acceptable and does not affect the Intertek WHI listing of components.

The FPI AstroCap XLTM is certified for installations using FPI venting systems as well as Simpson Dura-Vent®Direct Vent GS and Selkirk Direct-Temp. AstroCap XLTM is a proprietary trademark of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent GS are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc.

Regency® P40-1 Direct Vent Gas Fireplace

15

Image 15
Contents P40 Gas Fireplace Information for MOBILE/MANUFACTURED Homes After First Sale Manufactured Mobile Home RequirementsTable of Contents Copy of Safety Label InstallationFor the State of Massachusetts only MA Code CO DetectorDimensions Before YOU Start General Safety InformationInstallation Checklist Important MessageHearth Requirements Locating Your GAS FireplaceHeatwave Duct KIT Heat Release KITClearances P40 Mantel ClearancesMantel LEG Clearances P40 FireplaceFraming & Finishing Full Screen Door Facing RequirementsHeight = 42-1/2 plus height of hearth Unit Assembly Prior to Installation Venting IntroductionVent Restrictor Position Exterior Vent Termination Requirements Horizontal Termination Flex Venting ArrangementsRigid Pipe Venting Systems Basic Horizontal & Vertical TerminationsHorizontal Termination 58DVA-16AB 8 Rigid Pipe Cross Reference Chart58DVA-RD Offset Pipe SelectionHorizontal Feet Vertical Height Feet Allowable Horizontal TerminationsOption + V1 H + H1 Option + H1Option + H1 V + OptionVent must be supported at offsets Allowable Vertical TerminationsArrow on the vent cap should be pointing up Unit Installation with Horizontal TerminationMinimum Vent Unit Installation With Vertical TerminationThis allows for small adjustments DiagramAstrocap XL Dimensions Unit InstallationP40-NG1 System Data GAS Line InstallationPilot Adjustment High ElevationPower Module GAS Pipe Pressure TestingBACK-UP Battery Installation Unplug the power sourceLP Conversion Kit Contains Qty Description Conversion KIT #502-969 from NG to LPControl Module Modulating CoilJ9 Jumper NG Conversion Kit Contains Qty Description Conversion KIT #502-966 from LP to NGJ9 Jumper Location Top Brick Panel Brick Panel InstallationBack Brick Panel Brick Panels Completely Installed Ensure that the logs are not in the unitLOG SET Installation 03-3203-40 03-34 03-33 03-341st Log Stand Post 03-36 03-37 03-46 03-3303-33 03-46 03-36 03-3703-34 03-40 03-46 03-47 03-382 03-46 03-3603-38 03-36 03-32 03-37Flush Louvers Aeration AdjustmentInstalling the Manual Control Box Standard Flush DoorWiring Diagram Finishing TrimDo not cut the ground terminal off under any circumstances Full Screen Doors Full Screen Door Frame InstallationUpper Air Register InstallationOperating Instructions Lighting ProcedureShutdown Procedure Matching Remote Handset & Control BOX ID CodeOperation During Power Outage First FireDo not Burn the Appliance Without the Glass Front in Place Normal Operating Sounds GAS Appliances Summary ControlsFor Your Safety Read Before Lighting STOP! Read the safety information above on this labelCopy of Lighting Plate Instructions Thermopile Thermocouple Maintenance InstructionsGeneral Vent Maintenance LOG ReplacementGlass Replacement Door Glass FAN ReplacementSolenoid Valve Compression Fittings Valve ReplacementWire Log StandRing Tabs DC Sparker ReplacementPower Module Replacement Wa & Wb WiresControl Module Replacement Backup Battery ReplacementHeat Shield Main Assembly Parts ListValve Tray Assembly Parts ListFlush Door & Louvers Regency P40-1 Direct Vent Gas Fireplace Regency P40-1 Direct Vent Gas Fireplace Regency P40-1 Direct Vent Gas Fireplace Warranty Installer Please complete the following information

P40-LP1, P40-NG1 specifications

The Regency P40-LP1 and P40-NG1 are notable advancements in the realm of modern technology, particularly designed for energy efficiency and enhanced performance in various applications. These two models cater to the diverse needs of industries striving for both sustainability and productivity.

The P40-LP1 is engineered with a focus on low-pressure applications, utilizing cutting-edge technology to ensure optimal performance in energy consumption. This model features an advanced energy management system that intelligently adjusts power usage based on demand, which not only reduces operational costs but also minimizes the environmental impact. Its compact design and lightweight materials allow for easy installation in various settings, making it a versatile option for multiple industries.

On the other hand, the P40-NG1 is tailored for natural gas applications, making it an ideal choice for environments where natural gas is the primary energy source. This model is equipped with high-efficiency burners that maximize combustion efficiency, producing fewer emissions compared to traditional systems. The P40-NG1 also incorporates an integrated control system, providing users with real-time data monitoring to optimize performance and facilitate preventative maintenance.

Both models are constructed with durable materials designed to withstand harsh operating conditions, ensuring longevity and reliability. Advanced insulation technology further enhances their efficiency by reducing heat loss, allowing these systems to maintain consistent performance over extended periods.

A standout feature of the P40 series is its commitment to user-friendliness. The intuitive interface allows operators to easily navigate settings and access critical system information with minimal training. Additionally, these units are compatible with smart technologies, enabling seamless integration into existing infrastructure for enhanced operational oversight.

In summary, the Regency P40-LP1 and P40-NG1 embody the future of energy solutions, combining efficiency, adaptability, and user-focused design. Whether it’s for low-pressure or natural gas applications, these products deliver reliable performance while adhering to environmental standards. With ongoing advancements in their technology, the P40 series stands as a testament to Regency’s dedication to innovation and sustainability in the energy sector.