Regency P40-LP1, P40-NG1 installation manual Option + H1, Option + V1 H + H1

Page 19

INSTALLATION

Horizontal Venting with Two (2) 90o Elbows

 

 

 

One 90o elbow = Two 45o elbows.

INSTALLATION

 

Option

 

V

H + H1

With

these options,

 

A)

2'

Min.

2' Max.

maximum total pipe length

 

 

B)

3'

Min.

5' Max.

is 30 feet with minimum

 

 

C)

4'

Min.

6' Max.

of 6

feet total vertical

 

 

and maximum 8 feet total

 

 

 

 

 

 

 

 

D)

5'

Min.

7' Max. horizontal.

 

 

E)

6' Min.

8' Max.

 

 

 

 

VENT RESTRICTOR SETTING:

 

 

 

H1

When total vertical exceeds total horizontal by 2x the vent

 

restrictor setting is set to 1.

 

 

 

 

 

 

 

 

V

 

 

 

 

 

 

 

Please note minimum 1 foot between 90o elbows is

 

 

required.

 

 

 

 

 

 

Horizontal Venting with Three (3) 90o Elbows

One 90o elbow = Two 45o elbows.

Option V

H

V + V1 H + H1

A)0' Min. 1' Max. 1' Min. 1' Max.

B)1' Min. 2' Max. 3' Min. 3' Max.

C)2' Min. 2' Max. 5' Min. 4' Max.

D)3' Min. 2' Max. 7' Min. 5' Max.

E)4' Min. 3 Max. 9' Min. 6' Max.

F)5' Min. 4' Max. 10' Min. 7' Max.

G)6' Min. 5' Max. 11' Min. 8' Max.

H)7' Min. 6' Max. 12' Min. 9' Max.

With these options, max. total pipe length is 30 feet with min. of 12 feet total vertical and max. 9 feet total horizontal.

Please note min. 1 foot between 90o elbows is required.

VENT RESTRICTOR SETTING:

When total vertical exceeds total horizontal by 3x the vent restrictor setting is set to 1.

Regency® P40-1 Direct Vent Gas Fireplace

19

Image 19
Contents P40 Gas Fireplace Information for MOBILE/MANUFACTURED Homes After First Sale Manufactured Mobile Home RequirementsTable of Contents Copy of Safety Label InstallationFor the State of Massachusetts only MA Code CO DetectorDimensions Before YOU Start General Safety InformationInstallation Checklist Important MessageHearth Requirements Locating Your GAS FireplaceHeatwave Duct KIT Heat Release KITClearances P40 Mantel ClearancesMantel LEG Clearances P40 FireplaceFull Screen Door Facing Requirements Framing & FinishingHeight = 42-1/2 plus height of hearth Venting Introduction Unit Assembly Prior to InstallationVent Restrictor Position Exterior Vent Termination Requirements Horizontal Termination Flex Venting ArrangementsBasic Horizontal & Vertical Terminations Rigid Pipe Venting SystemsHorizontal Termination 58DVA-16AB 8 Rigid Pipe Cross Reference Chart58DVA-RD Offset Pipe SelectionHorizontal Feet Vertical Height Feet Allowable Horizontal TerminationsOption + V1 H + H1 Option + H1Option + H1 V + OptionVent must be supported at offsets Allowable Vertical TerminationsArrow on the vent cap should be pointing up Unit Installation with Horizontal TerminationMinimum Vent Unit Installation With Vertical TerminationThis allows for small adjustments DiagramAstrocap XL Dimensions Unit InstallationP40-NG1 System Data GAS Line InstallationPilot Adjustment High ElevationPower Module GAS Pipe Pressure TestingBACK-UP Battery Installation Unplug the power sourceLP Conversion Kit Contains Qty Description Conversion KIT #502-969 from NG to LPModulating Coil Control ModuleJ9 Jumper NG Conversion Kit Contains Qty Description Conversion KIT #502-966 from LP to NGJ9 Jumper Location Top Brick Panel Brick Panel InstallationBack Brick Panel Brick Panels Completely Installed Ensure that the logs are not in the unit03-32 LOG SET Installation03-40 03-33 03-34 03-341st Log Stand Post 03-36 03-37 03-46 03-3303-33 03-46 03-36 03-3703-34 03-40 03-46 03-47 03-382 03-46 03-3603-38 03-36 03-32 03-37Flush Louvers Aeration AdjustmentInstalling the Manual Control Box Standard Flush DoorFinishing Trim Wiring DiagramDo not cut the ground terminal off under any circumstances Full Screen Doors Full Screen Door Frame InstallationUpper Air Register InstallationOperating Instructions Lighting ProcedureShutdown Procedure Matching Remote Handset & Control BOX ID CodeFirst Fire Operation During Power OutageDo not Burn the Appliance Without the Glass Front in Place Normal Operating Sounds GAS Appliances Summary ControlsSTOP! Read the safety information above on this label For Your Safety Read Before LightingCopy of Lighting Plate Instructions Thermopile Thermocouple Maintenance InstructionsGeneral Vent Maintenance LOG ReplacementGlass Replacement Door Glass FAN ReplacementSolenoid Valve Compression Fittings Valve ReplacementWire Log StandRing Tabs DC Sparker ReplacementPower Module Replacement Wa & Wb WiresBackup Battery Replacement Control Module ReplacementHeat Shield Main Assembly Parts ListValve Tray Assembly Parts ListFlush Door & Louvers Regency P40-1 Direct Vent Gas Fireplace Regency P40-1 Direct Vent Gas Fireplace Regency P40-1 Direct Vent Gas Fireplace Warranty Installer Please complete the following information

P40-LP1, P40-NG1 specifications

The Regency P40-LP1 and P40-NG1 are notable advancements in the realm of modern technology, particularly designed for energy efficiency and enhanced performance in various applications. These two models cater to the diverse needs of industries striving for both sustainability and productivity.

The P40-LP1 is engineered with a focus on low-pressure applications, utilizing cutting-edge technology to ensure optimal performance in energy consumption. This model features an advanced energy management system that intelligently adjusts power usage based on demand, which not only reduces operational costs but also minimizes the environmental impact. Its compact design and lightweight materials allow for easy installation in various settings, making it a versatile option for multiple industries.

On the other hand, the P40-NG1 is tailored for natural gas applications, making it an ideal choice for environments where natural gas is the primary energy source. This model is equipped with high-efficiency burners that maximize combustion efficiency, producing fewer emissions compared to traditional systems. The P40-NG1 also incorporates an integrated control system, providing users with real-time data monitoring to optimize performance and facilitate preventative maintenance.

Both models are constructed with durable materials designed to withstand harsh operating conditions, ensuring longevity and reliability. Advanced insulation technology further enhances their efficiency by reducing heat loss, allowing these systems to maintain consistent performance over extended periods.

A standout feature of the P40 series is its commitment to user-friendliness. The intuitive interface allows operators to easily navigate settings and access critical system information with minimal training. Additionally, these units are compatible with smart technologies, enabling seamless integration into existing infrastructure for enhanced operational oversight.

In summary, the Regency P40-LP1 and P40-NG1 embody the future of energy solutions, combining efficiency, adaptability, and user-focused design. Whether it’s for low-pressure or natural gas applications, these products deliver reliable performance while adhering to environmental standards. With ongoing advancements in their technology, the P40 series stands as a testament to Regency’s dedication to innovation and sustainability in the energy sector.