2.Technical Information Cont.
ENERGY CAPACITY
Nominal heat input | MBH | 122.8 | |
(0/2000ft) | |||
|
| ||
Nominal heat input | MBH | 116.7 | |
(2000/4500ft) | |||
|
| ||
Minimum heat input | MBH | 49.5 | |
|
|
| |
Maximum useful output | MBH | 100.7 | |
(0/2000ft) | |||
|
| ||
Maximum useful output | MBH | 95.9 | |
(2000/4500ft) | |||
|
| ||
Minimum useful output | MBH | 37.0 | |
|
|
|
GAS SUPPLY PRESSURE
Gas |
| Normal | Min | Max |
|
|
|
|
|
Natural | inwc | 7.0 | 3.5 | 10.5 |
|
|
|
|
|
Propane | inwc | 11.0 | 8.0 | 12.0 |
|
|
|
|
|
GAS PRESSURE AT BURNER
Gas |
| Min | Max | Ignition |
|
|
|
|
|
Natural | inwc | 0.8 | 5.3 | 2.4 |
|
|
|
|
|
Propane | inwc | 1.4 | 9.0 | 5.2 |
|
|
|
|
|
FLUE DESIGN
Minimum Venturi pressure | inwc | 0.64 | |
|
|
| |
Flue pipe diameter |
|
| |
|
|
| |
Coaxial | in | 2.25/4 | |
3.25/5 | |||
|
| ||
Twin split pipes | in | 3.25/3.25 | |
Nominal heat flow rate | MBH | 122.8 | |
(0/2000ft) | |||
|
| ||
Nominal heat flow rate | MBH | 116.7 | |
(2000/4500ft) | |||
|
| ||
Min Exhaust temperature | °F | 262 | |
|
|
| |
Max Exhaust temperature | °F | 324 |
INJECTORS |
| No. |
| Size | |||||
Natural |
|
|
| 14 |
| 130 | |||
|
|
|
|
|
|
|
|
|
|
Propane |
|
|
| 14 |
| 89 | |||
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| |
GAS FLOW RATE |
|
|
|
|
| ||||
Gas |
|
|
|
| Min |
|
| Max | |
|
|
|
|
|
|
|
|
|
|
Natural |
| ft³/h |
|
| 48.7 |
| 121.1 | ||
|
|
|
|
|
|
|
|
|
|
Propane |
| lb/h |
|
| 2.23 |
| 5.55 | ||
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |||
ELECTRICAL |
|
|
|
|
| ||||
Voltage |
|
|
|
| V |
| 120 | ||
|
|
|
|
|
|
|
| ||
Frequency |
|
|
|
| Hz |
| 60 | ||
|
|
|
|
|
|
|
| ||
Current |
|
|
|
| A |
| < 1.6 | ||
|
|
|
|
|
| ||||
Power consumption |
| W |
| 176 | |||||
|
|
|
|
| |||||
|
|
|
| ||||||
FLUE GAS FIGURES |
|
| |||||||
Gas |
|
|
| Min |
| Max | |||
|
|
|
|
|
|
| |||
CO2 |
|
|
| 2.5% |
| 7.2% | |||
|
|
|
|
|
|
| |||
O2 |
|
|
| 16.5% |
| 8.1% | |||
|
|
|
|
|
|
|
|
|
|
RIVA HEAT ONLY MANUAL - REV A | 10 |