PB Heat Gas Boiler manual System Piping Freeze Protection, Pinnacle Circulator Sizing Graph

Page 10

WATER PIPING AND CONTROLS

Figure 3.2: Pinnacle Circulator Sizing Graph

 

21

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

19

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

17

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Head)

15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

of

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Feet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Drop

10

 

 

 

 

 

 

 

 

 

 

 

 

PI-T50

 

 

 

 

 

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pressure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

 

 

 

 

 

 

 

 

 

 

 

PI-T80/80

 

 

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

PI-140

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

PI-199

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

Flow Rate (GPM)

D. SYSTEM PIPING

E. FREEZE PROTECTION

1.Figure 3.3 shows a single boiler with two zones. In this application, the Peerless Partner indirect water heater and the single heating zone require similar water temperature.

2.Figure 3.4 shows an additional zone in which baseboard radiation is the heat load. This zone also requires water temperatures similar to the indirect water heater.

3.Figure 3.5 shows diverter tees used in combination with conventional hydronic radiators on an additional zone. A second boiler is also added to the system. Notice that the boilers are piped in parallel on the secondary loop. It is important that the common headers are sized to match the system piping. Smaller headers may result in flow fluctuations through the boilers.

4.Figure 3.6 shows a system in which several different types of loads and multiple boilers are shown. This system illustrates how different temperature zones can be supplied from the same source by mixing down the temperature using a three way mixing valve. Radiant flooring typically requires much lower temperatures than baseboard radiation and indirect water heating. Notice that a third boiler is included in this system.

5.Figure 3.7 shows zone valves used in place of zone circulators. Notice that this system utilizes reverse return piping which makes it easier to balance the system. If the heating zones are very different in length, the balancing valves on the return side of each loop are required.

1.Glycol for hydronic applications is specially formulated for this purpose. It includes inhibitors which prevent the glycol from attacking metallic system components. Make certain that the system fluid is checked for the correct glycol concentration and inhibitor level.

2.Use only inhibited propylene glycol solutions of up to 50% by volume. Ethylene glycol is toxic and can chemically attack gaskets and seals used in hydronic systems.

3.The antifreeze solution should be tested at least once per year and as recommended by the antifreeze manufacturer.

8

Image 10
Contents Peerless Pinnacle Table of Contents Installation Sequence Using this ManualSpecial Attention Boxes Codes & Regulations PreinstallationGeneral Accessibility Clearances Combustion and Ventilation AIRAccessibility Clearances Floor Standing Units Wall Hung Boilers Boiler SET-UPGeneral Floor Mounted BoilersOperating Parameters Water Piping and ControlsSystem Components Piping Symbol Key Boiler Inputs and Outputs Net I=B=R Output Model Btu/hr kWRecommended Circulators Boiler Flow Rate and Pressure Drop Boiler ModelFeet meters Grundfos CirculatorSystem Piping Freeze Protection Pinnacle Circulator Sizing GraphOne Boiler, Primary/Secondary with Two Zones Zone Circulator Water Piping and Controls Water Piping and Controls Water Piping and Controls Three Boilers, Primary/Secondary with Four Zones Zone Valves Special Applications Boiler in conjunction with a Chilled Water System Fuel Line Sizing GAS Supply Piping InstallationGAS Piping Feet PipeGAS Supply Piping Operation Gas Supply Piping Sediment TrapRecommended Vent CO² Settings Firing Gas Type Rate Main GAS Valve OperationApproved Materials for Exhaust Vent and Intake AIR Pipe Exhaust Vent / AIR Intake Pipe LocationExhaust Vent and Intake AIR Pipe Sizing Fitting Equivalent Length Table Fitting DescriptionExhaust Vent and AIR Intake Pipe Installation Vent Termination Kits Stock Description CodeVENTING, Inlet AIR and Condensate PI-T50 & PI-T80 Sidewall Venting with 2 Pipe 2 Vent Kit Venting with 3 Pipe Venting with 3 Pipe Concentric Vent Kit With 2 Pipe With 2 Pipe Concentric Vent KitExhaust Tapping for Vent Sample Condensate Drain InstallationBoiler Removal from Common Venting System Electrical WiringSequence of Operation Boiler Control Board Wiring Schematic Safety Interlocks Control FunctionsInstaller Menu Parameter Function Status Menu Description CodeSTART-UP Procedures Completing the InstallationFor Your Safety Read Before Operating Lighting and Operating ProceduresCHECK-OUT Procedure Boiler Error TroubleshootingBoiler Fault P125 Control Board Fault Codes Fault Code Description Corrective ActionWeekly with Boiler in USE MaintenanceGeneral with Boiler in USE Annually Before Start of Heating SeasonGAS Leaks Reset thermostats Important Make Boiler Dimensions & Ratings Boiler DimensionsPI-80/PI-140/PI-199 Dimensions Lbs Sch 40 PVCRepair Parts Repair Parts Advantages of the P125 Control Board Appendix A. WHAT’S NEW with the P125 Control BoardP125 Control Board Quick Reference P125 Control Board VS. WHA Control Board Comparison Figure A.2Comparative Control Board Sequence of OperationPeerless Pinnacle

Gas Boiler specifications

PB Heat Gas Boilers are renowned for their efficiency, reliability, and advanced technology, making them a popular choice for residential heating needs. With a range of models available, these boilers cater to various heating requirements while maintaining high performance and energy efficiency.

One of the standout features of PB Heat Gas Boilers is their exceptional efficiency ratings. Most models are designed to achieve AFUE (Annual Fuel Utilization Efficiency) ratings of over 90%, ensuring minimal energy waste and lower utility bills for homeowners. This high efficiency not only translates to cost savings but also contributes to a reduced carbon footprint, making PB Heat boilers a sustainable choice for environmentally conscious consumers.

PB Heat utilizes cutting-edge technologies to enhance the performance of their gas boilers. One such technology is the dual-stage gas valve, which allows for better modulation of gas flow, enabling the boiler to adapt to varying heating demands. This feature ensures consistent comfort while minimizing unnecessary energy consumption. Additionally, many PB Heat models come equipped with smart controls that can be easily integrated with home automation systems, giving homeowners the ability to monitor and adjust their heating remotely for maximum convenience and efficiency.

Durability and ease of maintenance are also key characteristics of PB Heat Gas Boilers. Constructed from high-quality materials, these boilers are designed to withstand the rigors of day-to-day operation. Features such as a corrosion-resistant heat exchanger contribute to the longevity of the unit, while easily accessible components simplify routine maintenance tasks, reducing downtime and service costs.

PB Heat Gas Boilers are available in various configurations, including wall-mounted and floor-standing models, catering to different space and installation requirements. This versatility allows homeowners to choose a solution that best fits their living environment while ensuring optimal heating performance.

In conclusion, PB Heat Gas Boilers represent a blend of advanced technology, energy efficiency, and robust construction. With their high efficiency ratings, smart control options, and durable design, these boilers provide reliable heating solutions for homes of all sizes. Choosing a PB Heat Gas Boiler means investing in a product that not only delivers comfort but also aligns with energy-saving and sustainability goals.