Timing Command Dictionary | SET STROBE_WINDOW TIME |
|
|
//Timing file commands SET TIME SCALE 1 ns;
SET STROBE_WINDOW TIME 50; SET FORCE TIME 800 900; SET MEASURE TIME 400 850; SET CYCLE TIME 1000;
Figure A-11 shows the output strobe window for this example.
Test Cycle
PIs | X |
|
|
|
CLK |
|
|
|
|
POs | X | X | X | X |
| 0ns | 500ns |
| 100ns |
| 400 | 450 |
|
|
Strobe Window
(SET MEASURE TIME can occur anytime within this window)
Figure A-11. SET STROBE_WINDOW Timing Diagram
Related Commands
None.