Command Dictionary | Save Patterns |
|
|
None — A literal that excludes the scan data from the file.
∙-ENVironment (FastScan only)
An optional switch that includes information about the current FastScan environment into the pattern file as comments. The information includes the identification stamp number, the environment settings, and the DRC rules. The information is the same as the Report Environment and Report ID Stamp commands display.
∙
An optional switch that specifies for the tool to apply only one test setup procedure when both chain and scan test patterns are saved in one pattern file. The tool applies the single test setup procedure before the chain test patterns. The default behavior causes the tool to apply one test setup procedure before the chain test patterns and another before the scan test patterns.
∙
An optional switch that specifies for FastScan and FlexTest to save the following respective tests in the pattern file:
FastScan saves both the chain test and the scan test FlexTest saves both the chain test and the cycle test
∙
An optional switch that specifies for the tool to save only the chain test in the pattern file.
∙-SCan_test (FastScan only)
An optional switch that specifies for FastScan to save only the scan test in the pattern file.
∙-CYcle_test (FlexTest only)
An optional switch that specifies for FlexTest to save only the cycle test in the pattern file.
∙
An optional switch that changes all Z output values to the value specified by the last Set Z Handling command.