SET SINGLE_CYCLE TIME | Timing Command Dictionary |
|
|
SET SINGLE_CYCLE TIME
Scope: Enables special timing rules checking
Usage
SET SINGLE_CYCLE TIME integer
Description
Enables timing rules checking to ensure a single time exists for both scan and non- scan test cycles.
Some tester formats, such as Compass Scan, TDL 91, and
If you place this command in the timing file, the timing rules checker ensures compliance to the following conditions:
∙The period of all scan test procedures and timeplates equals either the single_cycle time or the number of cycles multiplied by the single_cycle time.
∙The period of all the pins equals the single_cycle time.
∙The timing specified in each timeplate corresponds to the timing specified in the super timeplate.
∙For each scan test procedure, each force event time on a clock pin occurs at the force offset time in each cycle, as specified in the super timeplate.
∙For each scan test procedure, each force event on a
Note that you can specify only one of the following commands in a timing file:
∙SET SINGLE_CYCLE TIME
∙SET SPLIT_BIDI_CYCLE TIME
FastScan and FlexTest Reference Manual, V8.6_4 |