Command Dictionary | Set Z Handling |
|
|
Set Z Handling
Tools Supported: FastScan and FlexTest
Scope: Setup mode
Usage
SET Z Handling {Internal state} {External state}
Description
Specifies how the tool handles high impedance signals for internal and external
The Set Z Handling command specifies how to handle the high impedance state for internal and external nets. If the high impedance value can be made to behave as a binary value, certain faults may become detectable. If you do not use this command to set the Z handling, the default value is X.
Arguments
∙Internal state
A literal pair that specifies how the tool handles high impedance values for internal
X — A literal that specifies to treat high impedance states as an unknown state. This is the default behavior upon invocation of the tool.
0 — A literal that specifies to treat high impedance states as a 0 state.
1 — A literal that specifies to treat high impedance states as a 1 state.
Hold (FlexTest Only) — A literal that specifies to hold the state previous to the high impedance.
∙External state
A literal pair that specifies how the tool handles high impedance values for external
X — A literal that specifies not to measure high impedance states; they cannot be distinguished from a 0 or 1 state. This is the default behavior upon invocation of the tool.