Set Gate Report | Command Dictionary |
|
|
SKew_load — A literal specifying use of the skew_load procedure. In the test procedure file, this procedure describes how to propagate the output value of the preceding scan cell into the master memory element of the current cell (without changing the slave), for all scan cells.
SHADOW_Control — A literal specifying use of the shadow_control procedure. In the test procedure file, this procedure describes how to load the contents of a scan cell into the associated shadow.
Master_observe — A literal specifying use of the master_observe procedure. In the test procedure file, this procedure describes how to place the contents of a master into the output of its scan cell.
SHADOW_Observe — A literal specifying use of the shadow_observe procedure. In the test procedure file, this procedure describes how to place the contents of a shadow into the output of its scan cell.
STate_stability — A literal specifying display of the simulation values for the load_unload procedure and the capture clock cycle that the tool used to determine the constant value state elements at the initial load time. The report separates the shift procedure values, load_unload procedure values, and the capture clock cycle with parentheses. This format provides information that is helpful when you are trying to debug boundary scan.
The state_stability option is not a procedure.
time — An optional positive integer, greater than 0, that specifies a time in the test procedure file.
∙Parallel_pattern pattern_number (FastScan Only)
A literal and integer pair that specifies the pattern number from the last simulation pass that you want the Report Gates command to use when displaying the value of a gate. The pattern_number must be an integer between 0 and 31
FastScan and FlexTest Reference Manual, V8.6_4 |