SET SKEW_FORCE TIME | Timing Command Dictionary |
|
|
SET SKEW_FORCE TIME
Scope: Sets timing information
Usage
SET SKEW_FORCE TIME “ pin_name” time_value_list
Description
Specifies input pin force time for particular pins in each timeframe.
While the SET FORCE TIME command specifies force times for all pins, the SET SKEW_FORCE TIME command lets you specify unique force times for a particular input pin for each timeframe in a test cycle.
Note that this timing file command is similar to the SKEW_FORCE_PI statement that FastScan uses in its TIMEPLATE description.
Arguments
∙“ pin_name”
The name of a primary input pin, which must be enclosed in
∙time_value_list
A set of time values indicating when the specified input pin forces should occur. Each skew force time should occur prior to the measure time in every timeframe.
The number of list values must equal the number of timeframes in the test cycle, as specified by the Set Test Cycle application command. Unlike the values in the SET FORCE TIME command, the position of the time values with the SET SKEW_FORCE TIME command correspond to the same timeframe. For example, the first specified time value occurs in the first timeframe.
FastScan and FlexTest Reference Manual, V8.6_4 |