SET SKEW_FORCE TIME

Timing Command Dictionary

 

 

SET SKEW_FORCE TIME

Scope: Sets timing information

Usage

SET SKEW_FORCE TIME pin_name” time_value_list

Description

Specifies input pin force time for particular pins in each timeframe.

While the SET FORCE TIME command specifies force times for all pins, the SET SKEW_FORCE TIME command lets you specify unique force times for a particular input pin for each timeframe in a test cycle.

Note that this timing file command is similar to the SKEW_FORCE_PI statement that FastScan uses in its TIMEPLATE description.

Arguments

pin_name

The name of a primary input pin, which must be enclosed in double-quotes, for which you want to specify unique timing.

time_value_list

A set of time values indicating when the specified input pin forces should occur. Each skew force time should occur prior to the measure time in every timeframe.

The number of list values must equal the number of timeframes in the test cycle, as specified by the Set Test Cycle application command. Unlike the values in the SET FORCE TIME command, the position of the time values with the SET SKEW_FORCE TIME command correspond to the same timeframe. For example, the first specified time value occurs in the first timeframe.

A-52

FastScan and FlexTest Reference Manual, V8.6_4

Page 804