Command Dictionary

Set Fails Report

 

 

Set Fails Report

Tools Supported: FastScan and FlexTest

Scope: All modes

Usage

SET FAils Report OFf ON

Description

Specifies whether the design rules checker displays clock rule failures.

The Set Fails Report command displays all clock rule failures of the design rules checker. The default mode upon invocation of the tool is Off.

Arguments

OFf

A literal that specifies for the design rules checker to not display clock failures. This is the default upon invocation of the tool.

ON

A literal that specifies for the design rules checker to display clock failures.

Examples

The following example displays clock failures from the design rules checking process:

add scan groups group1 scanfile

add scan chains chain1 group1 indata2 outdata4 add clocks 1 clock1

add clocks 0 clock2 set fails report on set system mode atpg

Related Commands

 

Add Clocks

Report Clocks

Delete Clocks

 

FastScan and FlexTest Reference Manual, V8.6_4

2-477

Page 505
Image 505
Mentor v8.6_4 manual Set Fails Report