Command Dictionary | Set Fails Report |
|
|
Set Fails Report
Tools Supported: FastScan and FlexTest
Scope: All modes
Usage
SET FAils Report OFf ON
Description
Specifies whether the design rules checker displays clock rule failures.
The Set Fails Report command displays all clock rule failures of the design rules checker. The default mode upon invocation of the tool is Off.
Arguments
∙OFf
A literal that specifies for the design rules checker to not display clock failures. This is the default upon invocation of the tool.
∙ON
A literal that specifies for the design rules checker to display clock failures.
Examples
The following example displays clock failures from the design rules checking process:
add scan groups group1 scanfile
add scan chains chain1 group1 indata2 outdata4 add clocks 1 clock1
add clocks 0 clock2 set fails report on set system mode atpg
Related Commands |
|
Add Clocks | Report Clocks |
Delete Clocks |
|
FastScan and FlexTest Reference Manual, V8.6_4 |