Report Capture Handling

Command Dictionary

 

 

Report Capture Handling

Tools Supported: FastScan

Scope: All modes

Prerequisites: You can use this command only after FastScan flattens the design to the simulation model, which happens when you first attempt to exit Setup mode or when you issue the Flatten Model command.

Usage

REPort CApture Handling [List SUmmary SOurces Sinks Gates]

Description

Displays any special data capture handling currently in use.

You can change how FastScan handles data capturing on level-sensitive and trailing-edge state elements by using the Add Capture Handling command. If you have not set up any special data capture handling, then the Report Capture Handling command does not generate a report.

Arguments

List

A literal that displays the handling settings (old, new, or X), whether the element is a sink or source, the instance pathname, and the gate identification number. This is the default.

SUmmary

A literal that displays the handling settings for both level-sensitive and trailing- edge state elements, the number of sources, the number of primitive gates in the flattened netlist between source and sink points, and the number of sinks.

SOurces

A literal that displays the gates that have source-point special data capture handling.

SInks

A literal that displays the gates that have sink-point special data capture handling.

2-272

FastScan and FlexTest Reference Manual, V8.6_4

Page 300
Image 300
Mentor v8.6_4 manual Report Capture Handling